Skip to content

Releases: autoprotocol/autoprotocol-python

v10.3.0

25 Apr 20:41
4795408
Compare
Choose a tag to compare
  • Added device_mode_params for x_mantis device
  • Added liha shape assertion to test
  • removed auto-assigning of rows and columns for dispense based on device. added validation
  • Added rows and columns declaration in tests
  • Added tubing logic to support shortname use for future
  • Add future todo to support source is tip-type, add test to check that it will support shortnames
  • removed any key where a value is not initially provided. included tests
  • removed default values for tests
  • Update to allow for unit or string for zdrop and nozzle size
  • added test to make sure it throws an error if a tempest-specific key is passed in for mantis
  • uncomment test
  • remove pipette tip name support

Co-authored-by: Josh N jdnowak01@gmail.com

  • autoprotocol/protocol.py
  • autoprotocol/util.py
  • autoprotocol/builders.py

Official driver testing is set to be done in separate task. PyPi issues required update to release.


What's Changed

  • SCIENG-223: Update dependencies to allow for mantis liquid handle dispense by @cj-bonilla in #393

Full Changelog: v10.2.4...v10.3.0

v10.2.4

18 Apr 23:25
60b81c9
Compare
Choose a tag to compare

What's Changed

New Contributors

Full Changelog: v10.2.3...v10.2.4

v10.2.3

03 Apr 20:51
45e24ed
Compare
Choose a tag to compare
  • Revert rec tip type assignment

  • bump version

What's Changed

New Contributors

Full Changelog: v10.2.2...v10.2.3

v10.2.2

02 Mar 00:05
30113a4
Compare
Choose a tag to compare

What's Changed

Full Changelog: v10.2.1...v10.2.2

v10.2.1

27 Feb 19:12
84665a7
Compare
Choose a tag to compare

What's Changed

Full Changelog: v10.2.0...v10.2.1

v10.2.0

24 Feb 20:38
2e554e7
Compare
Choose a tag to compare

What's Changed

Full Changelog: v10.1.1...v10.2.0

v10.1.1

23 Feb 22:29
59f6dae
Compare
Choose a tag to compare

What's Changed

  • release: 10.1.1 <2023-02-23>
  • feature: 378 Adjust 96-deep-kf and 96-v-kf container types true_max_vol to 1.8mL and added validations in MagBuilders class such that plates being put onto KF device do not exceed working vol with comb

Full Changelog: v10.1.0...v10.1.1

v10.1.0

15 Feb 22:00
87cfc4f
Compare
Choose a tag to compare
  • Release v10.1.0

  • update version file


Co-authored-by: Justin Guiel justinguiel@hal9000.txhq.net

What's Changed

  • SCIENG-175 Acoustic Transfer property overwrite fix by @jguiel in #383
  • Release Appy v10.1.0 by @jguiel in #384

Full Changelog: v10.0.0...v10.1.0

v10.0.0

02 Feb 21:44
8bce7b4
Compare
Choose a tag to compare

What's Changed

Full Changelog: v9.1.1...v10.0.0

v9.1.1

02 Feb 21:30
12b8909
Compare
Choose a tag to compare

What's Changed

Full Changelog: v9.1.0...v9.1.1