L1T EG relax of ID cuts (including HoE) for high pt objects above tower saturation #15013
L1T EG relax of ID cuts (including HoE) for high pt objects above tower saturation #15013
Conversation
… PR cms-l1t-offline #353 Conflicts: L1Trigger/L1TCalorimeter/src/firmware/Stage2Layer2EGammaAlgorithmFirmwareImp1.cc
A new Pull Request was created by @rekovic for CMSSW_8_1_X. It involves the following packages: L1Trigger/L1TCalorimeter @cmsbuild, @rekovic, @mulhearn, @davidlange6 can you please review it and eventually sign? Thanks. cms-bot commands are list here #13028 |
please test |
The tests are being triggered in jenkins. |
+1 |
This pull request is fully signed and it will be integrated in one of the next CMSSW_8_1_X IBs (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @slava77, @davidlange6, @Degano, @smuzaffar |
+1 |
This is a fix for L1T EG emulator of relaxing the ID cuts (including HoE) for high pt objects above tower saturation point (127.5 GeV)
It is basicaly adjusted PR cms-l1t-offline#353
This change has already been made in the firmware at P5.
Conflicts resolved:
L1Trigger/L1TCalorimeter/src/firmware/Stage2Layer2EGammaAlgorithmFirmwareImp1.cc