Print correct timestamp in HP beamspot txt file #22392
Conversation
The code-checks are being triggered in jenkins. |
+code-checks Logs: https://cmssdt.cern.ch/SDT/code-checks/cms-sw-PR-22392/3618 |
A new Pull Request was created by @sarafiorendi for master. It involves the following packages: Calibration/TkAlCaRecoProducers @ghellwig, @arunhep, @cerminar, @cmsbuild, @franzoni, @lpernie can you please review it and eventually sign? Thanks. cms-bot commands are listed here |
please test |
The tests are being triggered in jenkins. |
-1 Tested at: fb0056f You can see the results of the tests here: I found follow errors while testing this PR Failed tests: RelVals
When I ran the RelVals I found an error in the following worklfows: runTheMatrix-results/4.22_RunCosmics2011A+RunCosmics2011A+RECOCOSD+ALCACOSD+SKIMCOSD+HARVESTDC/step2_RunCosmics2011A+RunCosmics2011A+RECOCOSD+ALCACOSD+SKIMCOSD+HARVESTDC.log4.53 step2 runTheMatrix-results/4.53_RunPhoton2012B+RunPhoton2012B+HLTD+RECODR1reHLT+HARVESTDR1reHLT/step2_RunPhoton2012B+RunPhoton2012B+HLTD+RECODR1reHLT+HARVESTDR1reHLT.log |
Comparison not run due to runTheMatrix errors (RelVals and Igprof tests were also skipped) |
please test |
The tests are being triggered in jenkins. |
I thing the tests got stuck |
abort |
Jenkins tests are aborted. |
please test |
The tests are being triggered in jenkins. |
Comparison job queued. |
Comparison is ready Comparison Summary:
|
+1 |
This pull request is fully signed and it will be integrated in one of the next master IBs (tests are also fine). This pull request will now be reviewed by the release team before it's merged. @davidlange6, @slava77, @smuzaffar, @fabiocos (and backports should be raised in the release meeting by the corresponding L2) |
+1 |
This PR is a further refinement of the HP beamspot workflow (integrated with #22299).
It allows to print in the output .txt file the correct beginning-time of the lumi-section for which the BS is measured.