HCALDQM: Fix digi size reference for summary plots (10_1_X backport) #22971
HCALDQM: Fix digi size reference for summary plots (10_1_X backport) #22971
Conversation
A new Pull Request was created by @DryRun (David Yu) for CMSSW_10_1_X. It involves the following packages: DQM/HcalCommon @vazzolini, @kmaeshima, @dmitrijus, @cmsbuild, @jfernan2, @vanbesien can you please review it and eventually sign? Thanks. cms-bot commands are listed here |
please test |
The tests are being triggered in jenkins. |
Comparison job queued. |
Comparison is ready Comparison Summary:
|
+1 |
This pull request is fully signed and it will be integrated in one of the next CMSSW_10_1_X IBs (tests are also fine) and once validation in the development release cycle CMSSW_10_2_X is complete. This pull request will now be reviewed by the release team before it's merged. @davidlange6, @slava77, @smuzaffar, @fabiocos (and backports should be raised in the release meeting by the corresponding L2) |
+1 |
Backport of #22595 to 10_1_X (the original PR was intended for 10_1_X, but was merged in 10_2_X).
Fixes the digi size reference (HB, HE from 10 to 8) for the summary plots. Also moves the location of the reference from C++ (HcalCommon/interface/Constants.h) to python (DigiTask.py, and copied via import to HcalOnlineHarvesting.py and HcalOfflineHarvesting.py).