New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Phase2-hgx140 Change the ieta field to radius field for scintillator part #24331
Conversation
The code-checks are being triggered in jenkins. |
@cmsbuild Please test |
+code-checks Logs: https://cmssdt.cern.ch/SDT/code-checks/cms-sw-PR-24331/6074 |
The tests are being triggered in jenkins. |
A new Pull Request was created by @bsunanda for master. It involves the following packages: DataFormats/ForwardDetId @cmsbuild, @civanch, @kpedro88, @mdhildreth can you please review it and eventually sign? Thanks. cms-bot commands are listed here |
Comparison job queued. |
Comparison is ready Comparison Summary:
|
+1 |
@bsunanda a point of clarification about the geometry, I can think of two cases:
Can you clarify which case is true? |
I believe all scintillator positions are non-projective. They are at constant radius so that the tile size in each layer for a given eta/radius index are of identical size. The sizes are surely different in FH and BH part (FH is finer than BH) |
Okay, then this change makes sense. Thanks! |
+upgrade |
This pull request is fully signed and it will be integrated in one of the next master IBs (tests are also fine). This pull request will now be reviewed by the release team before it's merged. @davidlange6, @slava77, @smuzaffar, @fabiocos (and backports should be raised in the release meeting by the corresponding L2) |
+1 |
Maintain the ieta() method to keep up backward compatibility. But it is better to remove this in future after verifying the downstream codes.