New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
TriggerRatesMonitor: fix booking of L1 Tech trigger rate plots #6310
TriggerRatesMonitor: fix booking of L1 Tech trigger rate plots #6310
Conversation
A new Pull Request was created by @fwyzard (Andrea Bocci) for CMSSW_7_3_X. TriggerRatesMonitor: fix booking of L1 Tech trigger rate plots It involves the following packages: DQM/HLTEvF @nclopezo, @danduggan, @rovere, @cmsbuild, @deguio, @ojeda can you please review it and eventually sign? Thanks. |
+1 |
1 similar comment
+1 |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_3_X IBs unless changes or unless it breaks tests. This pull request requires discussion in the ORP meeting before it's merged. @nclopezo, @ktf, @ktf, @davidlange6, @smuzaffar |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_3_X IBs unless changes (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @nclopezo, @ktf, @davidlange6, @smuzaffar |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_3_X IBs unless changes (tests are also fine). This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @nclopezo, @ktf, @smuzaffar |
…_plots_73x TriggerRatesMonitor: fix booking of L1 Tech trigger rate plots
No description provided.