Allow half/Quarter sized modules in a chassis #18925

Closed
benkhesa1 opened this issue Mar 17, 2025 · 1 comment
Closed

Allow half/Quarter sized modules in a chassis #18925

benkhesa1 opened this issue Mar 17, 2025 · 1 comment
Labels
type: feature Introduction of new functionality to the application

Comments

@benkhesa1
Copy link

NetBox version

4.2.1

Feature type

Change to existing functionality

Proposed functionality

Hi All,

 I'm try to model an ARUBA 6410v2 chassis in Netbox that has 2 half size management modules (R0X31A):

Image

Regards,

Use case

If I try to use module bay, then it'll take all the 1U size. If I try to use device bay, then I can't address/view this device as part of the chassis: Device bay requires it's their identity (name, IP,...) and can't use the one of the chassis. Virtual chassis are not also useful as they're often used for switch in stack. So far, I used this type https://github.com/netbox-community/devicetype-library/blob/master/device-types/HPE/Aruba-6410-v2.yaml . I have the same issue also modeling the PSUs: this chassis has 4 in 1U.

So can we allow different width size modules in a chassis. If this change implies a lot of work, then what's the best solution to represent this device in netbox.

Database changes

No response

External dependencies

No response

@benkhesa1 benkhesa1 added status: needs triage This issue is awaiting triage by a maintainer type: feature Introduction of new functionality to the application labels Mar 17, 2025
@bctiemann
Copy link
Contributor

This idea has been proposed in the past and rejected as not supportable. For setups like the one described, there are two devices within a full-width 1U chassis and would need to be modeled as such, with the mounting bracket as the device containing the sub-devices (in the 2 device bays in this case). That gives you all the geometry and labeling necessary.

@bctiemann bctiemann closed this as not planned Won't fix, can't repro, duplicate, stale Mar 20, 2025
@jnovinger jnovinger removed the status: needs triage This issue is awaiting triage by a maintainer label Mar 20, 2025