forked from rossmann-engineering/EasyModbusTCP.NET
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathAddConnectionForm.cs
211 lines (186 loc) · 7 KB
/
AddConnectionForm.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
/*
Copyright (c) 2018-2020 Rossmann-Engineering
Permission is hereby granted, free of charge,
to any person obtaining a copy of this software
and associated documentation files (the "Software"),
to deal in the Software without restriction,
including without limitation the rights to use,
copy, modify, merge, publish, distribute, sublicense,
and/or sell copies of the Software, and to permit
persons to whom the Software is furnished to do so,
subject to the following conditions:
The above copyright notice and this permission
notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT.
IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM,
DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE,
ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE
OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
*/
using System;
using System.Drawing;
using System.ComponentModel;
using System.Windows.Forms;
namespace EasyModbusAdvancedClient
{
/// <summary>
/// Description of AddConnectionForm.
/// </summary>
public partial class AddConnectionForm : Form
{
private EasyModbusManager easyModbusManager;
private ConnectionProperties connectionProperties = new ConnectionProperties();
private bool editMode = false;
private int indexToEdit;
public AddConnectionForm(EasyModbusManager easyModbusManager)
{
//
// The InitializeComponent() call is required for Windows Forms designer support.
//
this.easyModbusManager = easyModbusManager;
InitializeComponent();
connectionProperties.ConnectionName = "Connection #"+(easyModbusManager.connectionPropertiesList.Count+1).ToString();
propertyGrid1.SelectedObject = connectionProperties;
//
// TODO: Add constructor code after the InitializeComponent() call.
//
}
public AddConnectionForm(EasyModbusManager easyModbusManager, int indexToEdit)
{
this.easyModbusManager = easyModbusManager;
InitializeComponent();
connectionProperties.ConnectionName = easyModbusManager.connectionPropertiesList[indexToEdit].ConnectionName;
connectionProperties.CycleTime = easyModbusManager.connectionPropertiesList[indexToEdit].CycleTime;
connectionProperties.CyclicFlag = easyModbusManager.connectionPropertiesList[indexToEdit].CyclicFlag;
connectionProperties.ModbusTCPAddress = easyModbusManager.connectionPropertiesList[indexToEdit].ModbusTCPAddress;
connectionProperties.Port = easyModbusManager.connectionPropertiesList[indexToEdit].Port;
connectionProperties.ComPort = easyModbusManager.connectionPropertiesList[indexToEdit].ComPort;
connectionProperties.SlaveID = easyModbusManager.connectionPropertiesList[indexToEdit].SlaveID;
connectionProperties.ModbusTypeProperty = easyModbusManager.connectionPropertiesList[indexToEdit].ModbusTypeProperty;
connectionProperties.modbusClient = easyModbusManager.connectionPropertiesList[indexToEdit].modbusClient;
propertyGrid1.SelectedObject = connectionProperties;
editMode = true;
this.indexToEdit = indexToEdit;
}
void Button2Click(object sender, EventArgs e)
{
this.Close();
}
void Button1Click(object sender, EventArgs e)
{
try
{
if (!editMode)
{
easyModbusManager.AddConnection(connectionProperties);
}
else
easyModbusManager.EditConnection(connectionProperties, indexToEdit);
}
catch (Exception exc)
{
MessageBox.Show(exc.Message, "Exception Adding connection", MessageBoxButtons.OK, MessageBoxIcon.Error);
}
this.Close();
}
}
public enum ModbusType
{
ModbusTCP = 0,
ModbusRTU = 1
}
public class ConnectionProperties
{
ModbusType modbusType;
[Browsable(true)]
[Category("Modbus Type")]
[Description("Modbus TCP or Modbus RTU")]
[DisplayName("Modbus Type")]
public ModbusType ModbusTypeProperty
{
get { return modbusType; }
set { modbusType = value; }
}
string connectionName = "Connection #1";
[Browsable(true)]
[Category("Connection properties")]
[Description("Unique Connection Name")]
[DisplayName("Connection Name")]
public string ConnectionName
{
get { return connectionName; }
set { connectionName = value; }
}
string modbusTCPAddress = "127.0.0.1";
[Browsable(true)]
[Category("Connection properties")]
[Description("IP-Address of Modbus-TCP Server")]
[DisplayName("IP Address of Modbus-TCP Server")]
public string ModbusTCPAddress
{
get { return modbusTCPAddress; }
set { modbusTCPAddress = value; }
}
int port = 502;
[Browsable(true)]
[Category("Connection properties")]
[Description("Port")]
[DisplayName("Port")]
public int Port
{
get { return port; }
set { port = value; }
}
string comPort = "COM1";
[Browsable(true)]
[Category("Connection properties")]
[Description("Serial COM-Port")]
[DisplayName("Serial COM-Port")]
public string ComPort
{
get { return comPort; }
set { comPort = value; }
}
int slaveID = 1;
[Browsable(true)]
[Category("Connection properties")]
[Description("Slave ID")]
[DisplayName("Slave ID")]
public int SlaveID
{
get { return slaveID; }
set { slaveID = value; }
}
bool cyclicFlag = false;
[Browsable(true)]
[Category("Connection properties")]
[Description("Enable cyclic data exchange")]
[DisplayName("Enable cyclic data exchange")]
public bool CyclicFlag
{
get {return cyclicFlag;}
set {cyclicFlag = value;}
}
int cycleTime = 100;
[Browsable(true)]
[Category("Connection properties")]
[Description("Cycle time for cyclic data exchange")]
[DisplayName("Cycle time")]
public int CycleTime
{
get {return cycleTime;}
set {cycleTime = value;}
}
System.Collections.Generic.List<FunctionProperties> functionPropertiesList = new System.Collections.Generic.List<FunctionProperties>();
[Browsable(false)]
public System.Collections.Generic.List<FunctionProperties> FunctionPropertiesList
{
get { return functionPropertiesList; }
set { functionPropertiesList = value; }
}
public EasyModbus.ModbusClient modbusClient;
public System.Threading.Timer timer;
}
}