Cell Module for ATTINY841 LEDs Green LED blinks if communication is received remains lit for the next 10 communication cycles, if the cell module received a identify request Blue LED blinks twice if the WDT (Watchdog) is triggerd. Triggered every 8 seconds if no communication received. Red LED is on with bypass mode blinks if bypass in PWM mode