<Technique name="UV/Vis Peak Table" version="0.90" extension="false"
xmlns="urn:org:astm:animl:schema:technique:draft:0.90"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="urn:org:astm:animl:schema:technique:draft:0.90 http://schemas.animl.org/current/animl-technique.xsd">
<Documentation>This technique definition defines the structure of UV/Vis peak tables. It describes a single peak table belonging to a single spectrum. This Technique does not specify a lot of sample or method parameters. It is expected that this information is kept with the UV/Vis spectroscopy ExperimentStep which performs the data acquisition.</Documentation>
<SampleRoleBlueprint name="Test Sample" samplePurpose="consumed" modality="optional" inheritable="true">
<Documentation>The sample which was examined. Filling in this information is optional. The sample data can be looked up through the ExperimentStep referenced in the UV/Vis Spectrum ExperimentDataReference.</Documentation>
</SampleRoleBlueprint>
<ExperimentDataRoleBlueprint name="UV/Vis Spectrum" experimentStepPurpose="consumed" maxOccurs="1"
modality="optional">
<Documentation>Spectrum from which this peak table was generated</Documentation>
</ExperimentDataRoleBlueprint>
<MethodBlueprint>
<CategoryBlueprint name="Peak Table Method" modality="required" maxOccurs="1">
<Documentation>Parameters describing how the peak table is generated</Documentation>
<ParameterBlueprint name="Peak Picking Method" parameterType="String">
<Documentation>Method used for peak finding</Documentation>
<AllowedValue>
<S>Maximum Data Point</S>
</AllowedValue>
<AllowedValue>
<S>Inflection Point of Peak Derivative</S>
</AllowedValue>
<AllowedValue>
<S>Integrated Area</S>
</AllowedValue>
<AllowedValue>
<S>Other</S>
</AllowedValue>
</ParameterBlueprint>
</CategoryBlueprint>
</MethodBlueprint>
<ResultBlueprint name="Peak Table">
<SeriesSetBlueprint name="Peak Table">
<SeriesBlueprint name="Max Position" seriesType="Float" modality="required" plotScale="none"
dependency="independent">
<Documentation>Position on x axis where the peak maximum appears.</Documentation>
<Quantity name="Wavelength"> &um; &nm; &pm; </Quantity>
<Quantity name="Reciprocal Length"> &reciprocal_cm; </Quantity>
<Quantity name="Energy"> &eV; </Quantity>
</SeriesBlueprint>
<SeriesBlueprint name="ID" seriesType="Int" modality="required" plotScale="none" dependency="independent">
<Documentation literatureReferenceID="ASTM E1947-98">Peak number identifying this particular peak.</Documentation>
</SeriesBlueprint>
<SeriesBlueprint name="Start Position" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation>Peak start position on x axis.</Documentation>
<Quantity name="Wavelength"> &um; &nm; &pm; </Quantity>
<Quantity name="Reciprocal Length"> &reciprocal_cm; </Quantity>
<Quantity name="Energy"> &eV; </Quantity>
</SeriesBlueprint>
<SeriesBlueprint name="End Position" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation>Peak end position on x axis.</Documentation>
<Quantity name="Wavelength"> &um; &nm; &pm; </Quantity>
<Quantity name="Reciprocal Length"> &reciprocal_cm; </Quantity>
<Quantity name="Energy"> &eV; </Quantity>
</SeriesBlueprint>
<SeriesBlueprint name="Width" seriesType="Float" modality="optional" plotScale="none" dependency="dependent">
<Documentation>Peak width at half maximum.</Documentation>
<Quantity name="Wavelength"> &um; &nm; &pm; </Quantity>
<Quantity name="Reciprocal Length"> &reciprocal_cm; </Quantity>
<Quantity name="Energy"> &eV; </Quantity>
</SeriesBlueprint>
<SeriesBlueprint name="Height" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">Computed height of the peak; in a scaled data unit. The unit
for this is the same as that of the raw-data.</Documentation>
<Quantity name="Wavelength"> &um; &nm; &pm; </Quantity>
<Quantity name="Reciprocal Length"> &reciprocal_cm; </Quantity>
<Quantity name="Energy"> &eV; </Quantity>
</SeriesBlueprint>
<SeriesBlueprint name="Percent Height" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">Computed height percent of the peak; the summation of all quantified peaks in a spectrum should be equal to 100.0.</Documentation>
</SeriesBlueprint>
<SeriesBlueprint name="Area" seriesType="Float" modality="optional" plotScale="none" dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">Computed area of the peak.</Documentation>
</SeriesBlueprint>
<SeriesBlueprint name="Percent Area" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">Compound area percent of the peak: the summation of all quantified peaks in a spectrum should be equal to 100.0.</Documentation>
</SeriesBlueprint>
<SeriesBlueprint name="Assignment" seriesType="String" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="JCAMP-DX LC-MS">Chemical structure assigned to this peak (use Substance ID)</Documentation>
</SeriesBlueprint>
<SeriesBlueprint name="Asymmetry" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">The peak asymmetry As measured as As=B/A, where A and B are the widths for the front and back parts of a peak, commonly measured at 10 % peak height for USP at 5 %.</Documentation>
</SeriesBlueprint>
<SeriesBlueprint name="Baseline Start Value" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">Starting value of the computed baseline for this peak; in a scaled data unit, the unit for this is the same as that of the ordinate variable.</Documentation>
<Quantity name="Absorbance"> &AU; &A; </Quantity>
<Quantity name="Transmittance"> &T; &percentT; </Quantity>
<Quantity name="Reflectance"> &R; &percentR; </Quantity>
<Quantity name="Arbitrary"> &arbitrary;</Quantity>
</SeriesBlueprint>
<SeriesBlueprint name="Baseline Stop Value" seriesType="Float" modality="optional" plotScale="none"
dependency="dependent">
<Documentation literatureReferenceID="ASTM E1947-98">Ending value of the compound baseline for this peak; in a scaled data unit, the
unit for this is the same as that of the ordinate variable.</Documentation>
<Quantity name="Absorbance"> &AU; &A; </Quantity>
<Quantity name="Transmittance"> &T; &percentT; </Quantity>
<Quantity name="Reflectance"> &R; &percentR; </Quantity>
<Quantity name="Arbitrary"> &arbitrary;</Quantity>
</SeriesBlueprint>
</SeriesSetBlueprint>
</ResultBlueprint>
<Bibliography>
<LiteratureReference literatureReferenceID="ASTM E1947-98">
ASTM Standard E1947-98 (2009): Standard Specification for Analytical Data Interchange Protocol for Chromatographic Data, DOI: 10.1520/E1947-98R09
</LiteratureReference>