Go Modbus Client Adapter

Modbus Client Adapter

The modbus client adapter functions as a modbus master. The adapter allows an IoT gateway (or any other client) to function as a Modbus client in order to access data stored on modbus devices.

Communication with the Modbus Client Adapter is enabled through MQTT. Any gateway or device wishing to retrieve data from a Modbus device should publish a JSON message the the ClearBlade Platform message broker.

ClearBlade Platform Dependencies

The modbus client adapter adapter was constructed to provide the ability to communicate with a System defined in a ClearBlade Platform instance. Therefore, the adapter requires a System to have been created within a ClearBlade Platform instance.

Once a System has been created, artifacts must be defined within the ClearBlade Platform system to allow the adapter to function properly. At a minimum:

  • An adapter configuration data collection needs to be created in the ClearBlade Platform system and populated with data appropriate to the modbus client adapter adapter. The schema of the data collection should be as follows:
Column Name Column Datatype
adapter_name string
topic_root string

MQTT Topic Structure

The Modbus client adapter utilizes MQTT messaging to communicate with the ClearBlade Platform. The Modbus client adapter will subscribe to a specific topic in order to handle Modbus device requests. Additionally, the Modbus client adapter will publish messages to MQTT topics in order to communicate the results of requests to Modbus devices. The topic structures utilized by the Modbus client adapter are as follows:

  • Modbus Device Request: {TOPIC ROOT}/request
  • Modbus Device Response: {TOPIC ROOT}/response
  • Modbus Device Error: {TOPIC ROOT}/error

MQTT Message structure

Modbus Device Request Payload Format

The payload of a Modbus Device Request should have the following

/**
 * @typedef Request
 * @parameter {string} ModbusHost IP Address of ModbusHost
 * @parameter {number} FunctionCode Modbus function to execute on the Modbus device
 * @parameter {number} StartAddress address associated with the coil/register to be accessed
 * @parameter {number} AddressCount number of sequential addresses to be accessed
 * @parameter {number[]} Data - Array of integers (register requests) or booleans (coil/contact requests)
 * @example
      {
            "ModbusHost": "192.168.0.9:502",
            "FunctionCode": 1, 
            "StartAddress": 0, 
            "AddressCount": 3, 
            "Data": [2, 3, 4] 
      }
 */

Where

ModbusHost

  • REQUIRED
  • The host name and port of the modbus server to contact

FunctionCode

  • REQUIRED
  • The Modbus function to execute on the Modbus device
    • 1 - Read Coil
    • 2 - Read Discrete Input
    • 3 - Read Holding Registers
    • 4 - Read Input Registers
    • 5 - Write Single Coil
    • 6 - Write Single Holding Register
    • 15 - Write Multiple Coils
    • 16 - Write Multiple Holding Registers

StartAddress

  • REQUIRED
  • The address associated with the coil/register to be accessed

AddressCount

  • OPTIONAL
  • If more than one coil/register are to be accessed, the AddressCount property indicates the number of sequential addresses to be accessed, beginning with the address specified by the StartAddress property.

Data

  • REQUIRED for function codes 5, 6, 15, and 16
  • The data to be written to Modbus device coils/registers, contained within an array
  • Modbus coils store boolean only data. Function codes 5 and 15, therefore, require an array of boolean values.
    • [true, false, true, true, etc.]
  • Modbus registers store 16 bit registers. Function codes 6 and 16, therefore, require an array of integer values.
    • [5, 246, 34, etc.]

Modbus Device Response Payload Format

/**
 * @typedef Response
 * @parameter {Request} request
 * @parameter {Object} response
 * @param {number|number[]} response.Data number (or array) depending on Function code
 * @example

    {
      "request": {
            "ModbusHost": "192.168.0.9:502",
            "FunctionCode": 1, 
            "StartAddress": 0, 
            "AddressCount": 3, 
            "Data": [2, 3, 4] 
      },
      "response": {
          "Data": [45,2,5]
      }
    }
  */

Where

response.Data

  • Will contain an array of boolean values, for function codes 1 and 2
  • Will contain an array of 16-bit integers, for function codes 3 and 4
  • Will contain an array with a single boolean value representing the value written to the coil, for function code 5
  • Will contain an array with a single 16-bit value representing the value written to the register, for function code 6
  • Will contain an array with a single integer value representing the number of coils written to, for function code 15
  • Will contain an array with a single integer value representing the number of registers written to, for function code 16

Modbus Device Error Response Payload Format

/**
 * @typedef Response
 * @parameter {Request} request
 * @parameter {string} error
 * @example

      {
      "request": {
            "ModbusHost": "192.168.0.9:502",
            "FunctionCode": 1, 
            "StartAddress": 0, 
            "AddressCount": 3, 
            "Data": [2, 3, 4] 
      },
      "error": "malformed JSON"
    }
  */

Where

error

  • Will contain a string describing the error condition encountered

Executing the adapter

modbusClientAdapter -systemKey=<PLATFORM SYSTEM KEY> -systemSecret=<PLATFORM SYSTEM KEY> -deviceID=<AUTH DEVICE NAME> -activeKey=<AUTH DEVICE ACTIVE KEY> -platformURL=<CB PLATFORM URL> -messagingURL=<CB PLATFORM MESSAGING URL> -adapterConfigCollectionID=<CB DATA COLLECTION NAME> -topicRoot=<MQTT_TOPIC_ROOT> -logLevel=<LOG LEVEL>

Where

systemKey

  • REQUIRED
  • The system key of the ClearBLade Platform System the adapter will connect to

systemSecret

  • REQUIRED
  • The system secret of the ClearBLade Platform System the adapter will connect to

deviceID

  • REQUIRED
  • The device name the modbus client adapter will use to authenticate to the ClearBlade Platform
  • Requires the device to have been defined in the Auth - Devices collection within the ClearBlade Platform System

activeKey

  • REQUIRED
  • The active key the adapter will use to authenticate to the platform
  • Requires the device to have been defined in the Auth - Devices collection within the ClearBlade Platform System

platformURL

  • The url (including the port number) of the ClearBlade Platform instance the adapter will connect to
  • OPTIONAL
  • Defaults to http://localhost:9000

messagingUrl

  • The MQTT url (including the port number) of the ClearBlade Platform instance the adapter will connect to
  • OPTIONAL
  • Defaults to localhost:1883

adapterConfigCollectionID

  • See the Runtime Configuration section below
  • OPTIONAL

topicRoot

  • The root hierarchy of the MQTT topic tree that should be used when subscribing to MQTT topics or publishing to MQTT topics
  • OPTIONAL

logLevel

  • The level of runtime logging the adapter should provide.
  • Available log levels:
    • fatal
    • error
    • warn
    • info
    • debug
  • OPTIONAL
  • Defaults to info
  • Logging information will automatically be written to /var/log/modbusClientAdapter

Runtime Configuration

Modbus Client Adapter

Runtime configuration, utilizing the data collection described in the ClearBlade Platform Dependencies section above, provides the ability to specify an MQTT topic root dynamically. If a topic root is specified in the data collection, the topic root specified in the data collection will override any topic root specified on the command line when starting the adapter. When the topic root is specified, or modified, within the data collection, the modbus client adapter MUST be restarted in order for the changes to be in effect at runtime.

Setup


The mtsIo adapter is dependent upon the ClearBlade Go SDK and its dependent libraries being installed. The mtsIo adapter was written in Go and therefore requires Go to be installed (https://golang.org/doc/install).

Adapter compilation

In order to compile the adapter for execution, the following steps need to be performed:

  1. Retrieve the adapter source code
    • git clone git@github.com:ClearBlade/Modbus-Adapter.git
  2. Navigate to the modbusClientAdapter directory
    • cd go/modbusClientAdapter
  3. Compile the adapter
    • GOARCH=arm GOARM=5 GOOS=linux go build