The laser coolant water needs changing #146

Closed
DefProc opened this issue May 21, 2015 · 2 comments

Comments

@DefProc
Copy link

commented May 21, 2015

as mentioned in #145

@amcewen

This comment has been minimized.

Copy link
Member

commented May 26, 2015

It definitely does need a change. The flow sensor had disabled the laser on Saturday, because there was a build up of sludge blocking the coolant flow - luckily the blockage was in the curve just before the flow sensor, and working the tube by hand freed things up.

@DefProc

This comment has been minimized.

Copy link
Author

commented May 31, 2015

Done, although it needs some ethyl-glycol based coolant and algae inhibitor adding.