Permalink
Browse files

Update config ZWave release

  • Loading branch information...
jphomi committed Sep 30, 2017
1 parent c6290c1 commit 634fa6dd892381b0431d8c621642dc52ffde1bc2
Showing with 934 additions and 112 deletions.
  1. +28 −0 RELEASE/Drivers/Zwave/BeNext/P1dongle.xml
  2. +24 −24 RELEASE/Drivers/Zwave/aeotec/zw100.xml
  3. +13 −10 RELEASE/Drivers/Zwave/aeotec/zw111.xml
  4. +5 −5 RELEASE/Drivers/Zwave/aeotec/zw122.xml
  5. +26 −0 RELEASE/Drivers/Zwave/dome/0101.xml
  6. +180 −0 RELEASE/Drivers/Zwave/fibaro/fgcd001.xml
  7. +12 −0 RELEASE/Drivers/Zwave/forest/fs2z5232000002.xml
  8. +5 −2 RELEASE/Drivers/Zwave/ge/14291-switch.xml
  9. +19 −0 RELEASE/Drivers/Zwave/ge/14292-toggle-switch.xml
  10. +8 −7 RELEASE/Drivers/Zwave/ge/14294-dimmer.xml
  11. +39 −0 RELEASE/Drivers/Zwave/ge/14295-dimmer-toggle.xml
  12. +65 −0 RELEASE/Drivers/Zwave/ge/26931-motion-switch.xml
  13. +5 −4 RELEASE/Drivers/Zwave/ge/receptacle.xml
  14. +24 −0 RELEASE/Drivers/Zwave/ge/zw4001-switch.xml
  15. +12 −0 RELEASE/Drivers/Zwave/inovelli/simple_module.xml
  16. +24 −0 RELEASE/Drivers/Zwave/linear/WADWAZ-1.xml
  17. +54 −4 RELEASE/Drivers/Zwave/manufacturer_specific.xml
  18. +7 −4 RELEASE/Drivers/Zwave/northq/nq9021.xml
  19. +7 −17 RELEASE/Drivers/Zwave/northq/nq9121.xml
  20. +10 −23 RELEASE/Drivers/Zwave/northq/nq92021.xml
  21. +2 −4 RELEASE/Drivers/Zwave/qees/reto-dimmer-plus.xml
  22. +2 −2 RELEASE/Drivers/Zwave/qubino/ZMNHADx.xml
  23. 0 RELEASE/Drivers/Zwave/schlage/{BE468CAM619.xml → BE468.xml}
  24. 0 RELEASE/Drivers/Zwave/schlage/{BE469NXCEN.xml → BE469.xml}
  25. +28 −0 RELEASE/Drivers/Zwave/shenzen_neo/ls01ch.xml
  26. +37 −0 RELEASE/Drivers/Zwave/shenzen_neo/ls02ch.xml
  27. +1 −1 RELEASE/Drivers/Zwave/shenzen_neo/nas-wr01z.xml
  28. +23 −0 RELEASE/Drivers/Zwave/vision/zl7261.xml
  29. +56 −0 RELEASE/Drivers/Zwave/zooz/zen06.xml
  30. +5 −5 RELEASE/Drivers/Zwave/{domux/dx2skz.xml → zooz/zen20.xml}
  31. +11 −0 RELEASE/Drivers/Zwave/zooz/zen21.xml
  32. +11 −0 RELEASE/Drivers/Zwave/zooz/zen22.xml
  33. +29 −0 RELEASE/Drivers/Zwave/zooz/zen22v2.xml
  34. +18 −0 RELEASE/Drivers/Zwave/zooz/zen23.xml
  35. +18 −0 RELEASE/Drivers/Zwave/zooz/zen24.xml
  36. +64 −0 RELEASE/Drivers/Zwave/zooz/zse30.xml
  37. +30 −0 RELEASE/Drivers/Zwave/zwave.me/iTemp.xml
  38. +32 −0 RELEASE/Drivers/Zwave/zwp/WD-100.xml
@@ -0,0 +1,28 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Set to Default" >
<Help>Set all configuration values to default values (factory settings).</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Enable HW Pullup" >
<Help>For some Smart meters you will need an external pullup resistor to receive the data, one of it is the Kaifa meter</Help>
</Value>
<Value type="short" genre="config" instance="1" index="4" label="Baud rate" size="2" value="1152">
<Help>value x 100 = baud rate</Help>
</Value>
<Value type="list" genre="config" instance="1" index="6" label="CRC check" size="1" value="1">
<Help></Help>
<Item label="CRC check enabled" value="1"/>
<Item label="CRC check disabled" value="0"/>
</Value>
</CommandClass>
<!-- Meter v4 as report -->
<CommandClass id="50" setasreport="true" />
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="8" label="LifeLine"/>
</Associations>
</CommandClass>
</Product>
@@ -12,23 +12,23 @@ version 1.07 (4.11.2016)
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
<Value type="short" index="3" genre="config" label="On time" units="seconds" min="1" max="15300" value="240">
<Value type="short" index="3" genre="config" label="On time" units="seconds" min="10" max="3600" value="240">
<Help>Duration that the motion sensor must observe no motion before it will return to the no-motion state.
If value greater than 255, effective value is rounded up to the nearest minute (255 -> 255 seconds, 256 -> 300 seconds)</Help>
</Value>
<Value type="list" index="4" genre="config" label="Enable Motion Sensor" min="0" max="1" value="5" size="1">
<Help>Enable Motion Sensor</Help>
<Help>Enable Motion Sensor, (1 minimum, 5 maximum sensitivity level)</Help>
<Item label="Disabled" value="0" />
<Item label="Enabled level 1 (minimum sensitivity)" value="1" />
<Item label="Enabled level 1" value="1" />
<Item label="Enabled level 2" value="2" />
<Item label="Enabled level 3" value="3" />
<Item label="Enabled level 4" value="4" />
<Item label="Enabled level 5 (maximum sensitivity)" value="5" />
<Item label="Enabled level 5" value="5" />
</Value>
<Value type="list" index="5" genre="config" label="Command Options" min="1" max="2" value="1" size="1">
<Help>Which commands to send when PIR motion sensor triggered
OZW Ideal Value is Binary Sensor Report</Help>
<Item label="Basic Set (default) " value="1" />
<Item label="Basic Set" value="1" />
<Item label="Binary Sensor Report" value="2" />
</Value>
<Value type="byte" index="8" genre="config" label="Awake timeout" min="8" max="255" value="30" size="1">
@@ -37,13 +37,12 @@ version 1.07 (4.11.2016)
Available rang: 8 to 255 seconds.
</Help>
</Value>
<Value type="short" index="9" genre="config" label="Current power mode" value="0" read_only="true">
<Help>
Report the current power mode and the product state for battery power mode.
Value1 (MSB): 0x00=USB power mode, 0x01=Battery power mode.
Value2 (LSB): 0x00= keep sleep state for Battery power mode, 0x01=keep awake for 10 minutes for battery power mode.
Note: this parameter cannot be used as Set usage.
</Help>
<Value type="list" genre="config" instance="1" index="9" label="Current power mode" min="0" max="257" size="2" value="0" read_only="true">
<Help>Report the current power mode and the product state for battery power mode</Help>
<Item label="USB power, sleeping mode after re-power on" value="0"/>
<Item label="USB power, keep awake for 10 minutes after re-power on" value="1"/>
<Item label="Battery power, sleeping mode after re-power on" value="256"/>
<Item label="Battery power, keep awake for 10 minutes after re-power on" value="257"/>
</Value>
<Value type="byte" index="39" genre="config" label="Low Battery" min="10" max="50" value="20" size="1">
<Help>Configure low battery value
@@ -56,7 +55,7 @@ version 1.07 (4.11.2016)
<Item label="Disabled" value="0" />
<Item label="Enabled" value="1" />
</Value>
<Value type="short" index="41" genre="config" label="Temperature Reporting Threshold" units="%" min="0" max="39321" value="20" size="2">
<Value type="short" index="41" genre="config" label="Temperature Reporting Threshold" units="C/F" min="0" max="39321" value="20" size="2">
<Help>Threshold change in temperature to induce an automatic report.
Note:
1. The unit is Fahrenheit for US version, Celsius for EU/AU version.
@@ -147,14 +146,14 @@ version 1.07 (4.11.2016)
E.g. The default lower limit is 50%, when the measurement is less than 50%, it will be triggered to send out a humidity sensor report.
</Help>
</Value>
<Value type="short" index="53" genre="config" label="Set the upper limit value of Lighting sensor" units="lux" min="0" max="100" value="1000" >
<Value type="short" index="53" genre="config" label="Set the upper limit value of Lighting sensor" units="lux" min="0" max="30000" value="1000" >
<Help>
When the measurement is more than this upper limit, which will trigger to sent out a sensor report.
Upper limit range: 0 to 30000 Lux.
E.g. The default upper limit is 1000Lux, when the measurement is more than 1000Lux, it will be triggered to send out a Lighting sensor report.
</Help>
</Value>
<Value type="short" index="54" genre="config" label="Set the lower limit value of Lighting sensor" units="lux" min="0" max="100" value="50" >
<Value type="short" index="54" genre="config" label="Set the lower limit value of Lighting sensor" units="lux" min="0" max="30000" value="100" >
<Help>
When the measurement is less than this lower limit, which will trigger to sent out a sensor report.
Lower limit range: 0 to 30000 Lux.
@@ -198,7 +197,7 @@ version 1.07 (4.11.2016)
E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time.
</Help>
</Value>
<Value type="byte" index="59" genre="config" label="Set the recover limit value of Lighting sensor" units="lux" min="1" max="50" value="100" >
<Value type="byte" index="59" genre="config" label="Set the recover limit value of Lighting sensor" units="10xlux" min="1" max="255" value="10" >
<Help>
Note:
1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit.
@@ -210,7 +209,7 @@ version 1.07 (4.11.2016)
E.g. The default recover limit value is 100 Lux, when the measurement is less than (Upper limit - 100), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 100), the lower limit report would be enabled one time.
</Help>
</Value>
<Value type="byte" index="60" genre="config" label="Set the recover limit value of Ultraviolet sensor" units="UV" min="1" max="50" value="5" >
<Value type="byte" index="60" genre="config" label="Set the recover limit value of Ultraviolet sensor" units="UV" min="1" max="5" value="2" >
<Help>
Note:
1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit.
@@ -244,7 +243,7 @@ version 1.07 (4.11.2016)
<Item label="Fahrenheit" value="2" />
</Value>
<Value type="list" index="81" genre="config" label="LED report" min="0" max="1" value="0" size="1">
<Help>LED when motion/vibration triggered</Help>
<Help>LED when motion (PIR) triggered</Help>
<Item label="Enable" value="0" />
<Item label="Disable" value="1" />
</Value>
@@ -307,13 +306,14 @@ version 1.07 (4.11.2016)
- If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery.</Help>
</Value>
<Value type="short" index="201" genre="config" label="Temperature Calibration" value="1">
<Help>The calibration value = standard value - measure value.
(the available value range is [-100, 100] or [-10C, 10C]).
<Help>Temperature calibration (the available value range is [-128,127] or [-12.8C,12.7C]).
Note:
1. The value contains one decimal point. E.g. if the value is set to 20, the calibration value is 2.0 (EU/AU version) or 2.0 (US version)
2. The calibration value = standard value - measure value.
If measure value =25.3 and the standard value = 23.2, so the calibration value= 23.2-25.3 = -2.1 (0xEB).
If the measure value =30.1 and the standard value = 33.2, so the calibration value= 33.2-30.1= 3.1 (0x1F).
1. High byte is the calibration value. Low byte is the unit (0x01=Celsius,0x02=Fahrenheit)
2. The calibration value (high byte) contains one decimal point.
E.g. if the value is set to 20 (0x1401), the calibration value is 2.0C (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0F (US version)
3. The calibration value (high byte) = standard value - measure value.
E.g. If measure value =25.3C and the standard value = 23.2C, so the calibration value= 23.2C - 25.3C= -2.1C (0xEB).
If the measure value =30.1C and the standard value = 33.2C, so the calibration value= 33.2C - 30.1C=3.1C (0x1F).
Default value: 1 for EU/AU version, 2 for US version.
</Help>
</Value>
@@ -2,6 +2,7 @@
<!--
Aeotec ZW111 Nano Dimmer, base on Engineering Spec 12/07/2016
Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
https://aeotec.freshdesk.com/helpdesk/attachments/6048080397
-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
@@ -135,19 +136,21 @@ Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
<Value type="int" index="113" genre="config" label="Send Interval for Reporting Group 3" units="seconds" min="0" max="2147483647" value="600">
<Help>Defines the time interval when the defined report for group 3 is sent.</Help>
</Value>
<Value type="list" index="120" genre="config" label="Set the external switch mode for S1" units="" min="0" max="3" size="1" value="0">
<Value type="list" index="120" genre="config" label="Set the external switch mode for S1" units="" min="0" max="4" size="1" value="0">
<Help>When the mode is determined, this mode value will not be reset after exclusion</Help>
<Item label="Enter automatic identification mode" value="0"/>
<Item label="Momentary button mode" value="1"/>
<Item label="3-way switch mode" value="2"/>
<Item label="2-state switch mode" value="3"/>
<Item label="Unidentified" value="0"/>
<Item label="2-state switch" value="1"/>
<Item label="3-way switch" value="2"/>
<Item label="Momentary button" value="3"/>
<Item label="Enter automatic identification" value="4"/>
</Value>
<Value type="list" index="121" genre="config" label="Set the external switch mode for S2" units="" min="0" max="3" size="1" value="0">
<Value type="list" index="121" genre="config" label="Set the external switch mode for S2" units="" min="0" max="4" size="1" value="0">
<Help>When the mode is determined, this mode value will not be reset after exclusion</Help>
<Item label="Enter automatic identification mode" value="0"/>
<Item label="Momentary button mode" value="1"/>
<Item label="3-way switch mode" value="2"/>
<Item label="2-state switch mode" value="3"/>
<Item label="Unidentified" value="0"/>
<Item label="2-state switch" value="1"/>
<Item label="3-way switch" value="2"/>
<Item label="Momentary button" value="3"/>
<Item label="Enter automatic identification" value="4"/>
</Value>
<Value type="list" index="122" genre="config" label="Touch panel port state" units="" min="0" max="5" size="1" value="0" read_only="true">
<Help>Get the state of touch panel port</Help>
@@ -21,14 +21,14 @@ http://products.z-wavealliance.org/products/2437
Available rang is 8 to 127 seconds.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="9" label="Current power mode" min="0" max="255" size="2" value="0" read_only="true">
<Value type="list" genre="config" instance="1" index="9" label="Current power mode" min="0" max="258" size="2" value="0" read_only="true">
<Help>Report the current power mode and the product state for battery power mode</Help>
<Item label="USB power, sleeping mode after re-power on" value="0"/>
<Item label="USB power, keep awake for 10 minutes after re-power on" value="256"/>
<Item label="USB power, always awake state" value="512"/>
<Item label="Battery power, sleeping mode after re-power on" value="1"/>
<Item label="USB power, keep awake for 10 minutes after re-power on" value="1"/>
<Item label="USB power, always awake state" value="2"/>
<Item label="Battery power, sleeping mode after re-power on" value="256"/>
<Item label="Battery power, keep awake for 10 minutes after re-power on" value="257"/>
<Item label="Battery power, always awake state" value="513"/>
<Item label="Battery power, always awake state" value="258"/>
</Value>
<Value type="int" genre="config" instance="1" index="10" label="Alarm time for the Buzzer" min="655360" max="2147483647" value="1968650" size="4">
<Help>
@@ -0,0 +1,26 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Dome Door/Window Sensor
https://docs.domeha.com/#configuration-command-class-parameters
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="short" genre="config" instance="1" index="1" label="Configuring the OFF Delay" units="second" value="0" min="0" max="65536" size="2">
<Help>This parameter sets the delay time from when the Door/Window Sensor sends the BASIC_SET command to Association Group 2 and when the BASIC_SET(0) is sent.,It accepts a value up to 65,535, in seconds.</Help>
</Value>

<Value type="byte" genre="config" instance="1" index="2" label="Basic Set Level" value="255" min="0" max="255" size="1">
<Help>This parameter sets the value sent by the BASIC_SET command to Association Group 2.</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" max_associations="5" label="Lifeline" />
<Group index="2" max_associations="5" label="Control Commands" />
<Group index="3" max_associations="5" label="Send Notification Report" />
<Group index="4" max_associations="5" label="Send Binary Sensor Report" />
</Associations>
</CommandClass>
</Product>