@@ -31,7 +31,7 @@
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="short" index="4" genre="config" label="C-Wire/Battery Status" read_only="true" units="" min="0" max="31" value="0" size="1">
<Value type="short" index="4" genre="config" label="C-Wire/Battery Status" read_only="true" units="" min="0" max="31" value="0" size="2">
<Help>
Read-only parameter
1 -> C-Wire
@@ -80,7 +80,7 @@
<Item label="Fast" value="1"/>
<Item label="Economy" value="2"/>
</Value>
<Value type="short" index="10" genre="config" label="Temperature Reporting Filter" units="F" min="0" max="124" value="124" size="1">
<Value type="short" index="10" genre="config" label="Temperature Reporting Filter" units="F" min="0" max="124" value="124" size="2">
<Help>
The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting. The thermostat will not report ambient temperature changes if the ambient temperature falls between these bounds. For example, if the upper bound is 80F and the lower bound is 60F, the thermostat will not send SENSOR_MULTI_LEVEL_REPORTS for ambient temperature values between 60F and 80F. The thermostat will only send ambient temperature changes if the
thermostat has been added to an association group (see Command Class Association) and the temperature reporting threshold is non-zero (see Temperature Reporting Threshold).
@@ -9,13 +9,13 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584516
<Value type="int" index="1" genre="config" label="Motor start delay time" units="ms" size="4" value="0">
<Help>Motor start delay time (ms)</Help>
</Value>
<Value type="short" index="5" genre="config" label="Opening time" units="ms" size="4" value="5000">
<Value type="short" index="5" genre="config" label="Opening time" units="ms" size="2" value="5000">
<Help>
Total time from endpoint of close go to endpoint of opening (ms).
This value set 0x00000000, will use the time of last calibration.
Default 5 seconds</Help>
</Value>
<Value type="short" index="6" genre="config" label="Closing time" units="ms" size="4" value="5000">
<Value type="short" index="6" genre="config" label="Closing time" units="ms" size="2" value="5000">
<Help>
Total time from endpoint of opening go to endpoint of close (ms).
This value set 0x00000000, will use the time of last calibration.
@@ -36,14 +36,14 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584701
<Item label="When the state of the Switch changes, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds." value="1"/>
<Item label="Night Light Mode" value="2" />
</Value>
<Value type="int" index="83" genre="config" label="Night Light Color" units="" min="0" max="16777215" size="3" value="14524637" read_only="true">
<Value type="int" index="83" genre="config" label="Night Light Color" units="" min="0" max="16777215" size="4" value="14524637" read_only="true">
<Help>Configure the RGB Value when in Night Light Mode.
Byte 1: Red Color
Byte 2: Green Color
Byte 3: Blue Color
</Help>
</Value>
<Value type="int" index="84" genre="config" label="RGB Brightness in Energy Mode" units="" min="0" max="16777215" size="3" value="5263440" read_only="true">
<Value type="int" index="84" genre="config" label="RGB Brightness in Energy Mode" units="" min="0" max="16777215" size="4" value="5263440" read_only="true">
<Help>Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode.
Byte 1: Red Color
Byte 2: Green Color
@@ -0,0 +1,190 @@
<?xml version="1.0" encoding="utf-8"?>
<!--
Aeotec ZW122 Water Sensor 6
http://products.z-wavealliance.org/products/2437
-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Basic get not supported -->
<CommandClass id="32" getsupported="false"/>
<!-- COMMAND_CLASS_BINARY_SENSOR. This class is in the list reported by the device, but it does not respond to requests-->
<CommandClass id="48" action="remove"/>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="list" genre="config" instance="1" index="2" label="Waking up for 10 minutes when re-power on" min="0" max="1" size="1" value="0">
<Help>Enable/Disable waking up for 10 minutes when re-power on (battery mode) the Water Sensor.</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="8" label="Timeout of awake after the Wake Up CC is sent out" min="8" max="127" units="seconds" value="30" size="1">
<Help>
Set the timeout of awake after the Wake Up CC is sent out.
Available rang is 8 to 127 seconds.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="9" label="Current power mode" min="0" max="255" size="2" value="0" read_only="true">
<Help>Report the current power mode and the product state for battery power mode</Help>
<Item label="USB power, sleeping mode after re-power on" value="0"/>
<Item label="USB power, keep awake for 10 minutes after re-power on" value="256"/>
<Item label="USB power, always awake state" value="512"/>
<Item label="Battery power, sleeping mode after re-power on" value="1"/>
<Item label="Battery power, keep awake for 10 minutes after re-power on" value="257"/>
<Item label="Battery power, always awake state" value="513"/>
</Value>
<Value type="int" genre="config" instance="1" index="10" label="Alarm time for the Buzzer" min="655360" max="2147483647" value="1968650" size="4">
<Help>
Set the alarm time for the Buzzer when the sensor is triggered.
1 to 255 Repeated cycle of Buzzer alarm.
256 to 65535 the time of Buzzer keeping ON state (MSB).
65536 to 2147483647 The time of Buzzer keeping OFF state.
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="39" label="Set the low battery value" min="10" max="50" value="20" units="%" size="1">
<Help>10% to 50%</Help>
</Value>
<Value type="list" genre="config" instance="1" index="48" label="Sensor report" min="0" max="1" size="1" value="1">
<Help>Enable/disable the sensor report</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="int" genre="config" instance="1" index="49" label="Upper limit value" size="4" min="65536" max="2147483647" value="26214400">
<Help>
Set the upper limit value (overheat).
0 Celsius unit
1 Fahrenheit unit
65536 to 2147483647 Temperature value.
Default: 0x01900000 => 40.0C
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="50" label="Lower limit value" size="4" min="65536" max="2147483647" value="0">
<Help>
Set the lower limit value (under heat).
0 Celsius unit
1 Fahrenheit unit
65536 to 2147483647 Temperature value
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="57" label="Recover limit value of temperature sensor" min="100" max="4080" value="5120" size="2">
<Help>
Set the recover limit value of temperature sensor.
Note:
1. When the current measurement less than or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit.
After that the upper limit report would be disabled again until the measurement less than or equal (Upper limit - Recover limit).
2. When the current measurement greater than or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit.
After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).
3. High byte is the recover limit value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit).
4. Recover limit range: 1.0 to 25.5 C/F (0x0100 to 0xFF00 or 0x0101 to 0xFF01).
E.g. The default recover limit value is 2.0 C/F (0x1400/0x1401), when the measurement is less than (Upper limit - 2), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 2), the lower limit report would be enabled one time.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="64" label="Unit of the automatic temperature report" min="0" max="1" size="1" value="0">
<Help>Set the default unit of the automatic temperature report in parameter 101-103</Help>
<Item label="Celsius" value="0"/>
<Item label="Fahrenheit" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="84" label="Get the state of tilt sensor" min="0" max="1" size="1" value="0" read_only="true">
<Help>Get the state of tilt sensor</Help>
<Item label="Horizontal" value="0"/>
<Item label="Vertical" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="86" label="Buzzer" min="0" max="1" size="1" value="1">
<Help>Enable/ disable the buzzer.</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="87" label="Sensor is triggered the buzzer will alarm" size="1" min="0" max="55" value="55">
<Help>
To set which sensor is triggered the buzzer will alarm.
1 If the Water leak is triggered, the buzzer will alarm.
2 If the vibration is triggered, the buzzer will alarm.
4 If the tilt sensor is triggered, the buzzer will alarm.
16 If the under heat is triggered, the buzzer will alarm.
32 If the overheat is triggered, the buzzer will alarm.
Note: if the value = 1+2+4+16+32=55, which means if any sensor is triggered, the buzzer will alarm.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="88" label="Probe 1 Basic Set on grp 3" min="0" max="2" size="1" value="0">
<Help>To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered.</Help>
<Item label="Send nothing" value="0"/>
<Item label="Presence/absence of water 0xFF/0x00" value="1"/>
<Item label="Presence/absence of water 0x00/0xFF" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="89" label="Probe 2 Basic Set on grp 4" min="0" max="2" size="1" value="0">
<Help>To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered.</Help>
<Item label="Send nothing" value="0"/>
<Item label="Presence/absence of water 0xFF/0x00" value="1"/>
<Item label="Presence/absence of water 0x00/0xFF" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="94" label="Battery report selection" min="0" max="1" size="1" value="0">
<Help>To set which power source level is reported via the Battery CC.</Help>
<Item label="USB power level" value="0"/>
<Item label="CR123A battery level" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="101" label="Unsolicited report" size="1" min="0" max="3" value="3">
<Help>
To set what unsolicited report would be sent to the Lifeline group.
</Help>
<Item label="Send Nothing" value="0"/>
<Item label="Battery Report" value="1"/>
<Item label="Multilevel sensor report for temperature" value="2"/>
<Item label="Battery Report and Multilevel sensor report for temperature" value="3"/>
</Value>
<Value type="int" genre="config" instance="1" index="111" label="Unsolicited report interval time" size="4" min="5" max="2678400" units="seconds" value="3600">
<Help>
To set the interval time of sending reports in Report group 1
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="135" label="Water leak event report selection" min="0" max="3" size="1" value="1">
<Help>To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device.</Help>
<Item label="Send nothing" value="0"/>
<Item label="Send notification report to association group 1" value="1"/>
<Item label="Send configuration 0x88 report to association group 2" value="2"/>
<Item label="Send notification report to association group 1 and Send configuration 0x88 report to association group 2" value="3"/>
</Value>
<Value type="list" genre="config" instance="1" index="136" label="Report Type to Send" size="1" min="0" max="2" value="0" read_only="true">
<Help>
When the parameter 0x87 is set to 2 or 3, it can get the sensor probes status through this configuration value.
</Help>
<Item label="Absence of water is triggered by probe 1 and 2" value="0"/>
<Item label="Presence of water is triggered by probe 1" value="1"/>
<Item label="Presence of water is triggered by probe 2" value="2"/>
<Item label="Presence of water is triggered by probe 1 and 2" value="3"/>
</Value>
<Value type="short" genre="config" instance="1" index="201" label="Temperature sensor calibration" size="2" value="0">
<Help>
Temperature calibration (the available value range is [-128, 127] or [-12.8C, 12.7C]).
Note:
1. High byte is the calibration value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit).
2. The calibration value (high byte) contains one decimal point. E.g.
if the value is set to 20 (0x1400), the calibration value is 2.0 C (EU/AU version) or if the value is set to 20 (0x1401), the calibration value is 2.0 F(US version).
3. The calibration value (high byte) = standard value - measure value.
E.g. If measure value =25.3C and the standard value = 23.2C, so the calibration value= 23.2C - 25.3C= -2.1C (0xEB).
If the measure value =30.1C and the standard value = 33.2C, so the calibration value= 33.2C - 30.1C=3.1C (0x1F).
</Help>
</Value>
<Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" size="1" value="0">
<Help>Lock/ unlock all configuration parameters</Help>
<Item label="Unlock" value="0"/>
<Item label="Lock" value="1"/>
</Value>
<Value type="list" index="255" genre="config" label="Reset To Factory Defaults" size="4" value="1" write_only="true">
<Help>Reset to factory defaults</Help>
<Item label="Normal" value="0"/>
<Item label="Reset to factory default setting" value="1"/>
<Item label="Reset to factory default setting and removed from the z-wave network" value="1431655765"/>
</Value>
</CommandClass>

<!-- Map endpoints to instances -->
<CommandClass id="96" mapping="endpoints"/>
<CommandClass id="142" ForceInstances="true"/>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" max_associations="5" label="Lifeline"/>
<Group index="2" max_associations="5" label="Send the configuration parameter 0x88"/>
<Group index="3" max_associations="5" label="Send Basic Set when the Sensor probe 1 is triggered"/>
<Group index="4" max_associations="5" label="Send Basic Set when the Sensor probe 2 is triggered"/>
</Associations>
</CommandClass>

</Product>
@@ -30,9 +30,8 @@
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="5" label="Group #1" />
<Group index="255" max_associations="1" label="Group #255" />
<Associations num_groups="1">
<Group index="255" max_associations="1" label="Group #255" auto="true"/>
</Associations>
</CommandClass>
</Product>
@@ -2,7 +2,12 @@

<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- This thermostat's setpoint descriptions are 0 based, not 1 -->
<CommandClass id="67" base="0" />
<CommandClass base="0" override_precision="2" request_flags="4" version="1" name="COMMAND_CLASS_THERMOSTAT_SETPOINT" id="67">
<Instance index="1"/>
<Value index="1" value="0.0" max="0" min="0" verify_changes="false" write_only="false" read_only="false" units="C" label="Heating" instance="1" genre="user" type="decimal"/>
<Value index="2" value="0.0" max="0" min="0" verify_changes="false" write_only="false" read_only="false" units="C" label="Cooling" instance="1" genre="user" type="decimal"/>
<Value index="3" value="0.0" max="0" min="0" verify_changes="false" write_only="false" read_only="false" units="C" label="Unused" instance="1" genre="user" type="decimal"/>
</CommandClass>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="short" index="1" genre="config" label="Temperature Threshold" min="1" max="100" value="5">
@@ -0,0 +1,11 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Danfoss Devolo Connect Z v1.05 014G0801
http://products.z-wavealliance.org/products/1506
-->
<!-- COMMAND_CLASS_BASIC does not respond to requests -->
<CommandClass id="32" action="remove"/>
<!-- This thermostat's setpoint descriptions are 0 based -->
<CommandClass id="67" base="0" override_precision="2"/>
</Product>