Program Version,EnergyPlus, Version 23.2.0-7636e6b3e9, YMD=2024.01.25 16:05, ************* Beginning Zone Sizing Calculations ** Warning ** ProcessScheduleInput: Schedule:Day:Interval="ECONOMIZER MAX OA FRACTION 70 PCT DEFAULT", Blank Schedule Type Limits Name input -- will not be validated. ** Warning ** ProcessScheduleInput: Schedule:Day:Interval="INFILTRATION HVAC OFF SCHEDULE SUMMER DESIGN DAY SCHEDULE", Blank Schedule Type Limits Name input -- will not be validated. ** Warning ** ProcessScheduleInput: Schedule:Day:Interval="INFILTRATION HVAC OFF SCHEDULE WINTER DESIGN DAY SCHEDULE", Blank Schedule Type Limits Name input -- will not be validated. ** Warning ** ProcessScheduleInput: Schedule:Year="ECONOMIZER MAX OA FRACTION 70 PCT", Blank Schedule Type Limits Name input -- will not be validated. ** Warning ** ProcessScheduleInput: Schedule:Constant="ALWAYS ON CONTINUOUS", Blank Schedule Type Limits Name input -- will not be validated. ** Warning ** CheckUsedConstructions: There are 12 nominally unused constructions in input. ** ~~~ ** For explicit details on each unused construction, use Output:Diagnostics,DisplayExtraWarnings; ** Warning ** GetInternalHeatGains: People="WAREHOUSE OFFICE PEOPLE" has comfort related schedules but no thermal comfort model selected. ** ~~~ ** If schedules are specified for air velocity, clothing insulation, and/or work efficiency but no thermal comfort ** ~~~ ** thermal comfort model is selected, the schedules will be listed as unused schedules in the .err file. ** ~~~ ** To avoid these errors, select a valid thermal comfort model or eliminate these schedules in the PEOPLE input. ** Warning ** Calculated design cooling load for zone=ZONE WAREHOUSE BULK A - STORY GROUND is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=ZONE WAREHOUSE BULK A END_A - STORY GROUND is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=ZONE WAREHOUSE BULK B - STORY GROUND is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=ZONE WAREHOUSE BULK B END_A - STORY GROUND is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=ZONE WAREHOUSE BULK C - STORY GROUND is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ** Warning ** Calculated design cooling load for zone=ZONE WAREHOUSE BULK C END_A - STORY GROUND is zero. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs. ************* Beginning System Sizing Calculations ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 1" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE FINE A - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 2" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE FINE A END_B - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 3" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE FINE B - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 4" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE FINE B END_B - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 5" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE FINE C - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 6" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE FINE C END_B - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** GetOAControllerInputs: Controller:MechanicalVentilation="CONTROLLER MECHANICAL VENTILATION 7" ** ~~~ ** Cannot locate a matching DesignSpecification:ZoneAirDistribution object for Zone="ZONE WAREHOUSE OFFICE - STORY GROUND". ** ~~~ ** Using default zone air distribution effectiveness of 1.0 for heating and cooling. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE FINE A - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 15KBTU/HR 9.7SEER 15KBTU/HR 14.0SEER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE FINE A END_B - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 10KBTU/HR 9.7SEER 10KBTU/HR 14.0SEER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE FINE B - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 63KBTU/HR 9.7SEER 66KBTU/HR 11.0EER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE FINE B END_B - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 41KBTU/HR 9.7SEER 42KBTU/HR 14.0SEER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE FINE C - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 14KBTU/HR 9.7SEER 15KBTU/HR 14.0SEER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE FINE C END_B - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 9KBTU/HR 9.7SEER 9KBTU/HR 14.0SEER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** The Standard Ratings is calculated for Coil:Cooling:DX:SingleSpeed = ZONE WAREHOUSE OFFICE - STORY GROUND PSZ-AC 1SPD DX AC CLG COIL 43KBTU/HR 9.7SEER 48KBTU/HR 14.0SEER but not at the AHRI test condition due to curve out of bound. ** ~~~ ** Review the Standard Ratings calculations in the Engineering Reference for this coil type. Also, use Output:Diagnostics, DisplayExtraWarnings for further guidance. ** Warning ** Meter:Custom="TOTALHVAC:ELECTRICITY", invalid Output Variable or Meter Name="PUMPS:ELECTRICITY". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:ELECTRICITY", invalid Output Variable or Meter Name="HEATREJECTION:ELECTRICITY". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:ELECTRICITY", invalid Output Variable or Meter Name="HUMIDIFICATION:ELECTRICITY". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:ELECTRICITY", invalid Output Variable or Meter Name="HEATRECOVERY:ELECTRICITY". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:ELECTRICITY", invalid Output Variable or Meter Name="HEATREJECTION:ELECTRICITY". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="HEATING:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="COOLING:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="FANS:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="PUMPS:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="HEATREJECTION:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="HUMIDIFICATION:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", invalid Output Variable or Meter Name="HEATRECOVERY:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:PROPANE", no items assigned ** ~~~ ** ...will not be shown with the Meter results. This may be caused by a Meter:Custom be assigned to another Meter:Custom. ** Warning ** Meter:Custom="COOLINGHVAC:PROPANE", invalid Output Variable or Meter Name="COOLING:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:PROPANE", invalid Output Variable or Meter Name="HEATREJECTION:PROPANE". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:PROPANE", no items assigned ** ~~~ ** ...will not be shown with the Meter results. This may be caused by a Meter:Custom be assigned to another Meter:Custom. ** Warning ** Meter:Custom="TOTALHVAC:NATURALGAS", invalid Output Variable or Meter Name="COOLING:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:NATURALGAS", invalid Output Variable or Meter Name="FANS:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:NATURALGAS", invalid Output Variable or Meter Name="PUMPS:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:NATURALGAS", invalid Output Variable or Meter Name="HEATREJECTION:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:NATURALGAS", invalid Output Variable or Meter Name="HUMIDIFICATION:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:NATURALGAS", invalid Output Variable or Meter Name="HEATRECOVERY:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:NATURALGAS", invalid Output Variable or Meter Name="COOLING:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:NATURALGAS", invalid Output Variable or Meter Name="HEATREJECTION:NATURALGAS". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:NATURALGAS", no items assigned ** ~~~ ** ...will not be shown with the Meter results. This may be caused by a Meter:Custom be assigned to another Meter:Custom. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="HEATING:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="COOLING:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="FANS:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="PUMPS:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="HEATREJECTION:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="HUMIDIFICATION:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", invalid Output Variable or Meter Name="HEATRECOVERY:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="TOTALHVAC:FUELOILNO2", no items assigned ** ~~~ ** ...will not be shown with the Meter results. This may be caused by a Meter:Custom be assigned to another Meter:Custom. ** Warning ** Meter:Custom="COOLINGHVAC:FUELOILNO2", invalid Output Variable or Meter Name="COOLING:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:FUELOILNO2", invalid Output Variable or Meter Name="HEATREJECTION:FUELOILNO2". ** ~~~ ** ...will not be shown with the Meter results. ** Warning ** Meter:Custom="COOLINGHVAC:FUELOILNO2", no items assigned ** ~~~ ** ...will not be shown with the Meter results. This may be caused by a Meter:Custom be assigned to another Meter:Custom. ** Warning ** Output:Meter: invalid Key Name="HEATING:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATING:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATING:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATING:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATING:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLING:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLING:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLING:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLING:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLING:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLING:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIORLIGHTS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIORLIGHTS:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIORLIGHTS:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIORLIGHTS:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIORLIGHTS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIORLIGHTS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIORLIGHTS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIORLIGHTS:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIORLIGHTS:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIORLIGHTS:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIORLIGHTS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIORLIGHTS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="EXTERIOREQUIPMENT:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="FANS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="FANS:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="FANS:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="FANS:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="FANS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="FANS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="PUMPS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATREJECTION:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="HUMIDIFICATION:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATRECOVERY:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:DISTRICTCOOLING" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:DISTRICTHEATINGWATER" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:WATER" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="GENERATORS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="DISTRICTCOOLING:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="DISTRICTHEATINGWATER:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="WATER:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="FUELOILNO2:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="PROPANE:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="RESPUBLICAREA:INTERIOREQUIPMENT:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="RESPUBLICAREA:INTERIORLIGHTS:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="ELEVATORS:INTERIOREQUIPMENT:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="REFRIGERATION:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:ELECTRICITY" - not found. ** Warning ** Output:Meter: invalid Key Name="PROPANE:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATING:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="TOTALHVAC:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLINGHVAC:PROPANE" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLINGHVAC:NATURALGAS" - not found. ** Warning ** Output:Meter: invalid Key Name="FUELOILNO2:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="HEATING:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="INTERIOREQUIPMENT:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="WATERSYSTEMS:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="TOTALHVAC:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="COOLINGHVAC:FUELOILNO2" - not found. ** Warning ** Output:Meter: invalid Key Name="DISTRICTCOOLING:FACILITY" - not found. ** Warning ** Output:Meter: invalid Key Name="DISTRICTHEATING:FACILITY" - not found. ** Warning ** Output:Meter:MeterFileOnly requested for "Electricity:Facility" (TimeStep), already on "Output:Meter". Will report to both eplusout.eso and eplusout.mtr ************* Testing Individual Branch Integrity ************* All Branches passed integrity testing ************* Testing Individual Supply Air Path Integrity ************* All Supply Air Paths passed integrity testing ************* Testing Individual Return Air Path Integrity ************* All Return Air Paths passed integrity testing ************* No node connection errors were found. ** Severe ** Invalid Actuated Component Unique Name =ZONEWAREHOUSEFINEBSTORYGROUNDPSZACMAXOASCH ** ~~~ ** Entered in EnergyManagementSystem:Actuator=SCH_FRACTION_OA_MAX_1 ** ~~~ ** Component Unique key name not found ** ~~~ ** Use Output:EnergyManagementSystem object to create .edd file for valid component names. ** Severe ** Invalid Actuated Component Control Type =SCHEDULE VALUE ** ~~~ ** Entered in EnergyManagementSystem:Actuator=SCH_FRACTION_OA_MAX_1 ** ~~~ ** Control Type not found ** ~~~ ** Use Output:EnergyManagementSystem object to create .edd file for valid component control types. ** Fatal ** Errors found in processing Energy Management System input. Preceding condition causes termination. ...Summary of Errors that led to program termination: ..... Reference severe error count=2 ..... Last severe error=Invalid Actuated Component Control Type =SCHEDULE VALUE ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning). ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages. ************* ************* ===== Final Error Summary ===== ************* The following error categories occurred. Consider correcting or noting. ************* Nominally Unused Constructions ************* ..The nominally unused constructions warning is provided to alert you to potential conditions that can cause ************* ..extra time during simulation. Each construction is calculated by the algorithm indicated in the HeatBalanceAlgorithm ************* ..object. You may remove the constructions indicated (when you use the DisplayExtraWarnings option). ************* ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. ************* EnergyPlus Sizing Error Summary. During Sizing: 13 Warning; 0 Severe Errors. ************* EnergyPlus Terminated--Fatal Error Detected. 182 Warning; 2 Severe Errors; Elapsed Time=00hr 00min 4.00sec