Skip to content
Permalink
master
Go to file
 
 
Cannot retrieve contributors at this time
798 lines (798 sloc) 33.7 KB
<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export>
<version>2.0</version>
<date>2015-09-15T17:46:26Z</date>
<groups>
<group>
<name>Extra Templates</name>
</group>
</groups>
<templates>
<template>
<template>Template HP E8212zl</template>
<name>Template HP E8212zl</name>
<description/>
<groups>
<group>
<name>Extra Templates</name>
</group>
</groups>
<applications>
<application>
<name>Fan</name>
</application>
<application>
<name>Power Supply</name>
</application>
<application>
<name>System</name>
</application>
<application>
<name>Temperature</name>
</application>
</applications>
<items>
<item>
<name>Device contact details</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>SNMPv2-MIB::sysContact.0</snmp_oid>
<key>sysContact</key>
<delay>3600</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<description>The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.</description>
<inventory_link>23</inventory_link>
<applications>
<application>
<name>System</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item>
<item>
<name>Device description</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>SNMPv2-MIB::sysDescr.0</snmp_oid>
<key>sysDescr</key>
<delay>3600</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<description>A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software.</description>
<inventory_link>14</inventory_link>
<applications>
<application>
<name>System</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item>
<item>
<name>Device location</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>SNMPv2-MIB::sysLocation.0</snmp_oid>
<key>sysLocation</key>
<delay>3600</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<description>The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.</description>
<inventory_link>24</inventory_link>
<applications>
<application>
<name>System</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item>
<item>
<name>Device name</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>SNMPv2-MIB::sysName.0</snmp_oid>
<key>sysName</key>
<delay>3600</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<description>An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.</description>
<inventory_link>3</inventory_link>
<applications>
<application>
<name>System</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item>
<item>
<name>Fan</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.1</snmp_oid>
<key>fan.status</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>Fan</name>
</application>
</applications>
<valuemap>
<name>HP E8212ZL</name>
</valuemap>
<logtimefmt/>
</item>
<item>
<name>Over-temperature Sensor</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.7</snmp_oid>
<key>Over-temperature.Sensor</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>System</name>
</application>
</applications>
<valuemap>
<name>HP E8212ZL</name>
</valuemap>
<logtimefmt/>
</item>
<item>
<name>Power Supply Sensor</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.2</snmp_oid>
<key>Power.Supply.Sensor</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<valuemap>
<name>HP E8212ZL</name>
</valuemap>
<logtimefmt/>
</item>
<item>
<name>Power Supply Sensor 2</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.3</snmp_oid>
<key>Power.Supply2.Sensor</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<valuemap>
<name>HP E8212ZL</name>
</valuemap>
<logtimefmt/>
</item>
<item>
<name>Power Supply Sensor 3</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.4</snmp_oid>
<key>Power.Supply3.Sensor</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<valuemap>
<name>HP E8212ZL</name>
</valuemap>
<logtimefmt/>
</item>
<item>
<name>Power Supply Sensor 4</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.5</snmp_oid>
<key>Power.Supply4.Sensor</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<valuemap>
<name>HP E8212ZL</name>
</valuemap>
<logtimefmt/>
</item>
<item>
<name>Switch Temperature</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.11.2.14.11.1.2.8.1.1.3.0</snmp_oid>
<key>switch.temp</key>
<delay>60</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>4</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>Temperature</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item>
<item>
<name>SysUptime</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>1</multiplier>
<snmp_oid>.1.3.6.1.2.1.1.3.0</snmp_oid>
<key>SysUptime</key>
<delay>300</delay>
<history>7</history>
<trends>60</trends>
<status>0</status>
<value_type>0</value_type>
<allowed_hosts/>
<units>uptime</units>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>0.01</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>System</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item>
</items>
<discovery_rules>
<discovery_rule>
<name>Network interfaces</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>IF-MIB::ifDescr</snmp_oid>
<key>ifDescription</key>
<delay>30</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>
<evaltype>0</evaltype>
<formula/>
<conditions/>
</filter>
<lifetime>30</lifetime>
<description>You may also consider using IF-MIB::ifType or IF-MIB::ifAlias for discovery depending on your filtering needs.&#13;
&#13;
{$SNMP_COMMUNITY} is a global macro.</description>
<item_prototypes>
<item_prototype>
<name>CRC errors on interface $1</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>RMON-MIB::etherStatsCRCAlignErrors.{#SNMPINDEX}</snmp_oid>
<key>CRC.Errors[{#SNMPVALUE}]</key>
<delay>120</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>CRC Errors</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template HP E8212zl:CRC.Errors[{#SNMPVALUE}].change()}&gt;1</expression>
<name>CRC Errors on on {HOST.NAME} interface {#SNMPVALUE}</name>
<url>http://h20564.www2.hp.com/hpsc/doc/public/display?docId=emr_na-c02597187</url>
<status>0</status>
<priority>3</priority>
<description>A Cyclic Redundancy Check (CRC) are a hash function designed to detect accidental changes to raw computer data. A CRC is a short binary sequence present on each block of data. When a block of data is read or received, the device repeats the calculation to check for a match. If the new CRC does not match the original CRC, then a data error is logged and the device can attempt to correct the data error by re-reading or requesting the block of data.</description>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
</discovery_rules>
<macros>
<macro>
<macro>{$SNMP_COMMUNITY}</macro>
<value>HP_switches@Public$</value>
</macro>
</macros>
<templates>
<template>
<name>Template ICMP Ping</name>
</template>
<template>
<name>Template SNMP Interfaces</name>
</template>
</templates>
<screens/>
</template>
</templates>
<triggers>
<trigger>
<expression>{Template HP E8212zl:Power.Supply2.Sensor.last()}=2</expression>
<name>Power Supply 2 on {HOST.HOST} is in Status BAD</name>
<url/>
<status>0</status>
<priority>4</priority>
<description>Bad Power supply in Switch</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply2.Sensor.last()}=3</expression>
<name>Power Supply 2 on {HOST.HOST} is in Status Warning</name>
<url/>
<status>0</status>
<priority>3</priority>
<description>likely to be a power supply in error state</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply2.Sensor.last()}=5</expression>
<name>Power Supply 2 on {HOST.HOST} is not connected</name>
<url/>
<status>0</status>
<priority>1</priority>
<description>Power Supply is not connected</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply3.Sensor.last()}=2</expression>
<name>Power Supply 3 on {HOST.HOST} is in Status BAD</name>
<url/>
<status>0</status>
<priority>4</priority>
<description>Bad Power supply in Switch</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply3.Sensor.last()}=3</expression>
<name>Power Supply 3 on {HOST.HOST} is in Status Warning</name>
<url/>
<status>0</status>
<priority>3</priority>
<description>likely to be a power supply in error state</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply3.Sensor.last()}=5</expression>
<name>Power Supply 3 on {HOST.HOST} is not connected</name>
<url/>
<status>0</status>
<priority>1</priority>
<description>Power Supply is not connected</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply4.Sensor.last()}=2</expression>
<name>Power Supply 4 on {HOST.HOST} is in Status BAD</name>
<url/>
<status>0</status>
<priority>4</priority>
<description>Bad Power supply in Switch</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply4.Sensor.last()}=3</expression>
<name>Power Supply 4 on {HOST.HOST} is in Status Warning</name>
<url/>
<status>0</status>
<priority>3</priority>
<description>likely to be a power supply in error state</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply4.Sensor.last()}=5</expression>
<name>Power Supply 4 on {HOST.HOST} is not connected</name>
<url/>
<status>0</status>
<priority>1</priority>
<description>Power Supply is not connected</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply.Sensor.last()}=2</expression>
<name>Power Supply on {HOST.HOST} is in Status BAD</name>
<url/>
<status>0</status>
<priority>4</priority>
<description>Bad Power supply in Switch</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply.Sensor.last()}=3</expression>
<name>Power Supply on {HOST.HOST} is in Status Warning</name>
<url/>
<status>0</status>
<priority>3</priority>
<description>likely to be a power supply in error state</description>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template HP E8212zl:Power.Supply.Sensor.last()}=5</expression>
<name>Power Supply on {HOST.HOST} is not connected</name>
<url/>
<status>0</status>
<priority>1</priority>
<description>Power Supply is not connected</description>
<type>0</type>
<dependencies/>
</trigger>
</triggers>
</zabbix_export>
You can’t perform that action at this time.