diff --git a/package.json b/package.json
index 5dc0970..a8ebe61 100755
--- a/package.json
+++ b/package.json
@@ -19,6 +19,7 @@
"test:corpus:ch-col": "node test/corpus/run_corpus_checks.js --corpus-file-path=test/corpus/dpe_immeuble_chauffage_collectif.csv",
"test:corpus:ch-mix": "node test/corpus/run_corpus_checks.js --corpus-file-path=test/corpus/dpe_immeuble_chauffage_mixte.csv",
"test:corpus:all": "npm run test:corpus && npm run test:corpus:ch-ind && npm run test:corpus:ch-col && npm run test:corpus:ch-mix",
+ "test:corpus:all+database": "npm run test:corpus:all && node test/corpus/corpus_database.js",
"qa:lint": "eslint .",
"qa:lint:fix": "npm run qa:lint -- --fix",
"qa:duplication": "jscpd",
diff --git a/src/14_generateur_ecs.js b/src/14_generateur_ecs.js
index 5ca2c69..f2743de 100644
--- a/src/14_generateur_ecs.js
+++ b/src/14_generateur_ecs.js
@@ -81,20 +81,25 @@ export function calc_Qdw_j(instal_ecs, becs_j) {
const type_installation = requestInput(de, du, 'type_installation');
- const Qdw_ind_vc = calc_Qdw_ind_j(becs_j);
+ const Qdw_ind_vc = calc_Qdw_ind_j(instal_ecs, becs_j);
const Qdw_coll_vc = calc_Qdw_col_j(instal_ecs, becs_j, type_installation);
- return (Qdw_ind_vc + Qdw_coll_vc) * 0.48;
+ return Qdw_ind_vc + Qdw_coll_vc;
}
// 15.2.3
-export function calc_Qdw_ind_j(becs_j) {
- return (0.1 * becs_j) / 8760.0;
+/**
+ * @param instal_ecs {InstallationEcsItem}
+ * @param becs_j {number}
+ */
+export function calc_Qdw_ind_j(instal_ecs, becs_j) {
+ const Rat_ecs = instal_ecs.generateur_ecs_collection.generateur_ecs.length > 1 ? 0.5 : 1;
+ return 0.1 * Rat_ecs * becs_j;
}
export function calc_Qdw_col_j(instal_ecs, becs_j, type_installation) {
if (type_installation.includes('installation collective')) {
- return (0.112 * becs_j) / 8760.0;
+ return 0.112 * becs_j;
}
return 0;
}
diff --git a/src/9_besoin_ch.js b/src/9_besoin_ch.js
index 68f1384..4be1e05 100644
--- a/src/9_besoin_ch.js
+++ b/src/9_besoin_ch.js
@@ -1,6 +1,5 @@
import enums from './enums.js';
import tvs from './tv.js';
-import { calc_Qdw_j } from './14_generateur_ecs.js';
import { calc_besoin_ecs_j } from './11_besoin_ecs.js';
import { calc_Qrec_gen_j } from './9_generateur_ch.js';
import { calc_ai_j, calc_as_j } from './6.1_apport_gratuit.js';
@@ -18,7 +17,9 @@ export default function calc_besoin_ch(
instal_ecs,
instal_ch,
bv,
- ets
+ ets,
+ th,
+ nbLogements
) {
const ca = enums.classe_altitude[ca_id];
const zc = enums.zone_climatique[zc_id];
@@ -48,10 +49,8 @@ export default function calc_besoin_ch(
* 11.4 Plusieurs systèmes d’ECS (limité à 2 systèmes différents par logement)
* Les besoins en ECS pour chaque générateur sont / 2
*/
- const prorataEcs = instal_ecs.length > 1 ? 0.5 : 1;
+ const prorataEcs = instal_ecs.length > 1 ? 1 / instal_ecs.length : 1;
- let Qdw_total_ecs = 0;
- let Qdw_total_ecs_dep = 0;
let Qgw_total_ecs = 0;
instal_ecs.forEach((instal_ecs) => {
let Qgw;
@@ -78,15 +77,16 @@ export default function calc_besoin_ch(
Qgw_total_ecs += (0.48 * Qgw * (instal_ecs.donnee_entree.rdim || 1)) / 8760;
});
- for (const mois of mois_liste) {
- // en kw/h
- const becsj = calc_besoin_ecs_j(ca, mois, zc, nadeq, false) * prorataEcs;
- // en kw/h
- const becs_j_dep = calc_besoin_ecs_j(ca, mois, zc, nadeq, true) * prorataEcs;
-
- Qdw_total_ecs += instal_ecs.reduce((acc, ecs) => acc + calc_Qdw_j(ecs, becsj), 0);
- Qdw_total_ecs_dep += instal_ecs.reduce((acc, ecs) => acc + calc_Qdw_j(ecs, becs_j_dep), 0);
- }
+ const { Qrec, Qrec_dep, sumNref19, sumNref21 } = calc_qrec(
+ instal_ecs,
+ nadeq,
+ prorataEcs,
+ ilpa,
+ ca,
+ zc,
+ th,
+ nbLogements
+ );
/**
* Création de la liste des générateurs de chauffage pour lesquels il y a une récupération d'énergie
@@ -144,8 +144,8 @@ export default function calc_besoin_ch(
pertes_generateur_ch_recup += gen_recup;
pertes_generateur_ch_recup_depensier += gen_recup_dep;
- const pertes_distribution_ecs_recup_j = nref19 * Qdw_total_ecs * 1000;
- const pertes_distribution_ecs_recup_j_dep = nref21 * Qdw_total_ecs_dep * 1000;
+ const pertes_distribution_ecs_recup_j = (Qrec * nref19) / sumNref19;
+ const pertes_distribution_ecs_recup_j_dep = (Qrec_dep * nref21) / sumNref21;
pertes_distribution_ecs_recup += pertes_distribution_ecs_recup_j;
pertes_distribution_ecs_recup_depensier += pertes_distribution_ecs_recup_j_dep;
@@ -153,6 +153,7 @@ export default function calc_besoin_ch(
pertes_stockage_ecs_recup += pertes_stockage_ecs_recup_j;
const pertes_stockage_ecs_recup_j_dep = nref21 * Qgw_total_ecs;
+ // Normalement en wh
besoin_ch_mois[mois] = bvj * dh19j;
besoin_ch_mois_dep[mois] = bvj_dep * dh21j;
besoin_ch_mois[mois] -=
@@ -160,8 +161,9 @@ export default function calc_besoin_ch(
besoin_ch_mois_dep[mois] -=
pertes_distribution_ecs_recup_j_dep + pertes_stockage_ecs_recup_j_dep + gen_recup_dep;
besoin_ch_mois[mois] = Math.max(besoin_ch_mois[mois], 0);
- besoin_ch += besoin_ch_mois[mois] / 1000;
+ // Besoin de chauffage final en kwh
+ besoin_ch += besoin_ch_mois[mois] / 1000;
besoin_ch_depensier += besoin_ch_mois_dep[mois] / 1000;
}
@@ -182,6 +184,57 @@ export default function calc_besoin_ch(
};
}
+function calc_qrec(instal_ecs, nadeq, prorataEcs, ilpa, ca, zc, th, nbLogements) {
+ const Nref21 = tvs.nref21[ilpa];
+ const Nref19 = tvs.nref19[ilpa];
+
+ let sumNref19 = 0;
+ let sumNref21 = 0;
+
+ for (const mois of mois_liste) {
+ const nref19 = Nref19[ca][mois][zc];
+ const nref21 = Nref21[ca][mois][zc];
+ sumNref19 += nref19;
+ sumNref21 += nref21;
+ }
+
+ let Qrec = 0;
+ let Qrec_dep = 0;
+ let total_becs_rdim = 0;
+ let total_becs_dep_rdim = 0;
+ instal_ecs.forEach((ecs) => {
+ let becs_int = 0;
+ let becs_dep_int = 0;
+ const isInstallationSimple = ecs.donnee_entree.enum_type_installation_id === '1';
+ const Tau = isInstallationSimple ? 0.1 : 0.212;
+ if (th === 'immeuble' && ecs.donnee_entree.rdim > 1) {
+ prorataEcs = ecs.donnee_entree.rdim / nbLogements;
+ }
+ for (const mois of mois_liste) {
+ // en kwh
+ becs_int += calc_besoin_ecs_j(ca, mois, zc, nadeq, false) * prorataEcs;
+
+ // en kwh
+ becs_dep_int += calc_besoin_ecs_j(ca, mois, zc, nadeq, true) * prorataEcs;
+ }
+
+ if (th !== 'immeuble') {
+ Qrec += ((0.48 * sumNref19 * Tau * becs_int) / 8760) * 1000;
+ Qrec_dep += ((0.48 * sumNref21 * Tau * becs_dep_int) / 8760) * 1000;
+ } else {
+ total_becs_rdim += Tau * becs_int * 1000;
+ total_becs_dep_rdim += Tau * becs_dep_int * 1000;
+ }
+ });
+
+ if (th === 'immeuble') {
+ Qrec = ((0.48 * sumNref19) / 8760) * total_becs_rdim;
+ Qrec_dep = ((0.48 * sumNref21) / 8760) * total_becs_dep_rdim;
+ }
+
+ return { Qrec, Qrec_dep, sumNref19, sumNref21 };
+}
+
function calc_Fj(GV, asj, aij, dhj, inertie) {
if (dhj === 0) return 0;
diff --git a/src/engine.js b/src/engine.js
index 379829f..f8cc590 100644
--- a/src/engine.js
+++ b/src/engine.js
@@ -428,7 +428,9 @@ export function calcul_3cl(dpe) {
ecs,
instal_ch,
bv_list,
- ets
+ ets,
+ th,
+ dpe.logement.caracteristique_generale.nombre_appartement
);
apport_et_besoin = { ...apport_et_besoin, ...besoin_ch };
diff --git a/test/fixtures/2378E0897918K.xml b/test/fixtures/2378E0897918K.xml
new file mode 100644
index 0000000..6b1a490
--- /dev/null
+++ b/test/fixtures/2378E0897918K.xml
@@ -0,0 +1,1357 @@
+
+
+ 2378E0897918K
+ ACTIF
+
+ 2023-02-22
+ 2023-03-03
+
+ 1
+ 2378E0877972G
+ 2.2
+
+ 3752
+ 3.1.1
+ 3cl_tribu_1.4.25.1
+
+
+
+
+
+
+
+
+
+
+ 78133000AD0154
+
+
+
+ 1062L LOGT : 0281 28 RUE DE LA SENTE NOIRE
+ 78240
+ CHAMBOURCY
+ 1062L LOGT : 0281 28 RUE DE LA SENTE NOIRE78240 CHAMBOURCY
+ 1--11-1062L-0281
+ 2023-03-03
+ 2
+
+
+
+
+
+
+ 1948
+ 2
+ 34
+ 79.00
+ 1
+ 4
+ 2.50
+ 1781.60
+ 0
+ 25
+
+
+ 1
+ 1
+ 0
+
+
+
+ 0
+ 0
+ 0
+ 2
+
+
+
+
+ Mur en béton banché Ep <=20cm avec isolant (ITE) Ep=7 cm
+ M01O02
+ 1
+ 1
+ 4
+ 129.1000
+ 115.0200
+ 81
+ 20.00
+ 13
+ 2
+ 0
+ 2
+ 4
+ 2
+ 7.00
+ 3
+
+
+ 1.000
+ 0.4651
+ 2.5000
+
+
+
+
+ Mur en béton banché Ep <=20cm avec isolant (ITE) Ep=7 cm
+ M01O03
+ 1
+ 1
+ 3
+ 107.7000
+ 93.6200
+ 81
+ 20.00
+ 13
+ 2
+ 0
+ 2
+ 4
+ 2
+ 7.00
+ 3
+
+
+ 1.000
+ 0.4651
+ 2.5000
+
+
+
+
+ Mur en béton banché Ep <=20cm avec isolant (ITE) Ep=7 cm
+ M01O04
+ 1
+ 1
+ 2
+ 470.0000
+ 315.6800
+ 81
+ 20.00
+ 13
+ 2
+ 0
+ 2
+ 4
+ 2
+ 7.00
+ 3
+
+
+ 1.000
+ 0.4651
+ 2.5000
+
+
+
+
+ Mur en béton banché Ep <=20cm non isolé
+ M02O01
+ 1
+ 1
+ 1
+ 509.3000
+ 157.5200
+ 81
+ 20.00
+ 13
+ 2
+ 0
+ 2
+ 2
+ 1
+
+
+ 1.000
+ 2.5000
+ 2.5000
+
+
+
+
+
+
+ Dalle de béton (ITE) Ep=5,5 cm
+ S01
+ 6
+ 6
+ 458.6000
+ 9
+ 9
+ 2
+ 4
+ 2
+ 5.50
+ 3
+ 1
+ 121.100
+ 458.600
+ 0.295
+
+
+ 1.000
+ 2.000
+ 0.295
+ 2.000
+
+
+
+
+ Dalle de béton non isolé
+ S02
+ 1
+ 1
+ 7.4100
+ 9
+ 9
+ 2
+ 2
+ 1
+ 0
+
+
+ 1.000
+ 2.000
+ 2.000
+ 2.000
+
+
+
+
+
+
+ Dalle de béton isolé à partir de 2013
+ T01O05
+ 1
+ 1
+ 441.000000000
+ 8
+ 8
+ 2
+ 4
+ 9
+ 92
+ 7
+
+
+ 1.000
+ 0.140
+ 2.500
+
+
+
+
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F01O01
+ M02O01
+ 1
+ 1
+ 184.8000000
+ 24
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 410
+ 5
+ 7
+ 0
+ 1.300
+ 0.390
+ 1
+ 6
+ 2
+ 0
+ 5
+ 126
+ 2
+ 1
+ 6
+ 6
+
+
+ 1.00
+ 1.100
+ 1.300
+ 1.200
+ 1.200
+ 0.390
+ 0.400
+ 0.800
+
+
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F02O01
+ M02O01
+ 1
+ 1
+ 166.9800000
+ 33
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 410
+ 5
+ 7
+ 0
+ 1.300
+ 0.390
+ 1
+ 6
+ 2
+ 0
+ 5
+ 126
+ 2
+ 1
+ 6
+ 6
+
+
+ 1.00
+ 1.100
+ 1.300
+ 1.200
+ 1.200
+ 0.390
+ 0.400
+ 0.800
+
+
+
+
+ Fen.bat./ocil. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F03O04
+ M01O04
+ 1
+ 1
+ 49.9200000
+ 48
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 330
+ 5
+ 4
+ 0
+ 1.400
+ 0.380
+ 1
+ 7
+ 2
+ 1
+ 5
+ 111
+ 2
+ 2
+ 19
+ 3
+
+
+ 1.00
+ 1.100
+ 1.400
+ 1.300
+ 1.300
+ 0.380
+ 1.000
+ 0.500
+
+
+
+
+ Fen.bat./ocil. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F04O04
+ M01O04
+ 1
+ 1
+ 43.6800000
+ 24
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 330
+ 5
+ 4
+ 0
+ 1.400
+ 0.380
+ 1
+ 7
+ 2
+ 1
+ 5
+ 111
+ 2
+ 2
+ 19
+ 3
+
+
+ 1.00
+ 1.100
+ 1.400
+ 1.300
+ 1.300
+ 0.380
+ 1.000
+ 0.500
+
+
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F05O04
+ M01O04
+ 1
+ 1
+ 60.7200000
+ 12
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 410
+ 5
+ 7
+ 0
+ 1.300
+ 0.390
+ 1
+ 6
+ 2
+ 1
+ 5
+ 126
+ 2
+ 2
+ 19
+ 3
+
+
+ 1.00
+ 1.100
+ 1.300
+ 1.200
+ 1.200
+ 0.390
+ 1.000
+ 0.500
+
+
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F06O02
+ M01O02
+ 1
+ 1
+ 14.0800000
+ 4
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 410
+ 5
+ 7
+ 0
+ 1.300
+ 0.390
+ 1
+ 6
+ 2
+ 1
+ 5
+ 126
+ 2
+ 4
+ 19
+ 10
+
+
+ 1.00
+ 1.100
+ 1.300
+ 1.200
+ 1.200
+ 0.390
+ 1.000
+ 0.770
+
+
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ F07O03
+ M01O03
+ 1
+ 1
+ 14.0800000
+ 4
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 410
+ 5
+ 7
+ 0
+ 1.300
+ 0.390
+ 1
+ 6
+ 2
+ 1
+ 5
+ 126
+ 2
+ 3
+ 19
+ 9
+
+
+ 1.00
+ 1.100
+ 1.300
+ 1.200
+ 1.200
+ 0.390
+ 1.000
+ 1.000
+
+
+
+
+
+
+
+
+ Liaison Mur extérieur / Plancher bas
+ i01j01num02
+ M01O04
+ S02
+ 9
+ 7.290
+ 1
+ 1
+ 1.000
+
+
+ 0.490
+
+
+
+
+ Liaison Mur extérieur / Plancher intermédiaire
+ i02j02num01
+ M02O01
+ NC
+ 29
+ 148.350
+ 1
+ 2
+ 0.500
+
+
+ 0.430
+
+
+
+
+ Liaison Mur extérieur / Plancher haut
+ i03j02num01
+ M02O01
+ T01O05
+ 38
+ 49.450
+ 1
+ 3
+ 1.000
+
+
+ 0.400
+
+
+
+
+ Liaison Mur extérieur / Refend
+ i05j02num01
+ M02O01
+ NC
+ 64
+ 70.000
+ 1
+ 4
+ 0.500
+
+
+ 0.365
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num001
+ M02O01
+ F01O01
+ 76
+ 189.600
+ 1
+ 5
+ 1.000
+
+
+ 0.250
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num002
+ M02O01
+ F02O01
+ 76
+ 221.100
+ 1
+ 5
+ 1.000
+
+
+ 0.250
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num003
+ M01O04
+ F03O04
+ 94
+ 201.600
+ 1
+ 5
+ 1.000
+
+
+ 0.200
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num004
+ M01O04
+ F04O04
+ 94
+ 129.600
+ 1
+ 5
+ 1.000
+
+
+ 0.200
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num005
+ M01O04
+ F05O04
+ 94
+ 80.400
+ 1
+ 5
+ 1.000
+
+
+ 0.200
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num006
+ M01O02
+ F06O02
+ 94
+ 24.000
+ 1
+ 5
+ 1.000
+
+
+ 0.200
+
+
+
+
+ Liaison Mur extérieur / Fenêtre et Portes-fenêtre
+ i06num007
+ M01O03
+ F07O03
+ 94
+ 24.000
+ 1
+ 5
+ 1.000
+
+
+ 0.200
+
+
+
+
+
+
+
+ 79.00
+ Ventil01
+
+ 1
+ 11
+ 1
+ 7
+ 7
+ 0
+
+ 0.04434
+
+
+ 1229.304
+ 1.900
+ 0.000
+ 182.587
+ 908.616
+
+
+
+
+
+
+
+ ProdEnR01
+ 0
+ 1
+
+
+ 0.00
+ 0.00
+ 0.00
+
+
+
+
+
+
+ Réseau de chaleur
+ Instal_Ecs01
+ 1
+ 3
+ 1
+ 79.00
+ 0.04434
+ 25.00
+ 1
+ 5
+ 2
+ 0
+
+
+ 0.26
+ 32294.28
+ 45558.00
+ 138009.74
+ 194692.31
+
+
+
+
+
+ I01Gene_Ecs01
+ 119
+ 2
+ 8
+ 1
+ 1
+ 3
+ 0
+ 1000.000
+
+
+ 1.00
+ 0.90000
+ 138009.74
+ 194692.3054
+
+
+
+
+
+
+
+
+ Emission n°1
+ Instal_Ch01
+ 79.00
+ 4
+ 8
+ 1.0000000
+ 3
+ 1
+
+
+ 98944.59
+ 127238.29
+ 129990.24
+ 167161.60
+
+
+
+
+ Radiateur HT sans robinet thermostatique
+ I01Emet_Ch01
+ 79.00
+ 7
+ 8
+ 11
+ 32
+ 164
+ 1
+ 6
+ 2
+ 1
+ 4
+ 1
+ 1
+
+
+ 1.03
+ 0.95
+ 0.87
+ 0.90
+
+
+
+
+
+
+ Raccordement à réseau de chaleur
+ I01Gene_Ch01
+ 142
+ 1
+ 8
+ 0
+ 31
+ 3
+ 1
+ 1
+
+
+ 60000.00
+ 0.97
+ 117084.35
+ 150565.20
+
+
+
+
+ PAC Géothermique
+ I01Gene_Ch02
+ 16
+ 1
+ 1
+ 0
+ 55
+ 3
+ 1
+ 1
+
+
+ 2.20
+ 120000.00
+ 12905.89
+ 16596.39
+
+
+
+
+
+
+
+ 5764.0
+ 6686.3
+ 6119.7
+ 8628.7
+ 43.3
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 138.5
+ 23.1
+ 0.0
+ 0.0
+ 12590.2
+ 159.370229
+
+
+ 6508.0
+ 7549.3
+ 8628.7
+ 6119.7
+ 99.6
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 318.6
+ 53.2
+ 0.0
+ 0.0
+ 14252.7
+ 180.414175
+ E
+
+
+ 2044.0
+ 2371.1
+ 3322.1
+ 2356.1
+ 3.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 8.9
+ 1.5
+ 0.0
+ 0.0
+ 4446.1
+ 56.279413
+ E
+
+
+ 502.8
+ 583.3
+ 481.6
+ 679.1
+ 149.3
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 477.5
+ 79.7
+ 0.0
+ 0.0
+ 1189.4
+
+
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+ 0.0
+
+
+
+ 1
+ 572.275
+ 0.000
+ 638.713
+ 0.000
+ 0.000
+ 4.469
+ 94.216
+ 0.000
+ 323.257
+
+
+ 8
+ 5191.773
+ 6119.650
+ 11311.420
+ 0.000
+ 0.000
+ 0.000
+ 408.613
+ 481.600
+ 890.213
+
+
+
+ 0.851
+ 4
+ 4
+ 2
+ 1
+
+
+ 0.000
+ 182.587
+ 1091.203
+ 637.670
+ 150.291
+ 61.740
+ 650.472
+ 0.000
+ 307.288
+ 2898.663
+
+
+ 772.552
+ 0.000
+ 0.000
+ 30216490.000
+ 56528150.000
+ 0.424
+ 0.424
+ 2172837.000
+ 2172837.000
+ 0.000
+ 0.000
+ 0.000
+ 49.332
+ 2762.581
+ 3897.212
+ 98944.590
+ 14559.000
+ 32294.280
+ 15322.000
+ 0.000
+ 0.000
+
+
+
+
+
+
+ 1062L-0271
+ 1
+ 3
+
+
+
+
+
+ géothermie
+ 5
+
+
+
+
+ Mur en béton banché Ep <=20cm avec isolant (ITE) Ep=7 cm
+ 1
+
+
+ Mur en béton banché Ep <=20cm non isolé
+ 1
+
+
+ Dalle de béton (ITE) Ep=5,5 cm
+ 2
+
+
+ Dalle de béton non isolé
+ 2
+
+
+ Dalle de béton isolé à partir de 2013
+ 3
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ 4
+
+
+ Fen.bat./ocil. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ 4
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ 4
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ 4
+
+
+ PF. sans soub. PVC double vitrage(VIR) argon 20mm Avec ferm.
+ 4
+
+
+ Radiateur HT sans robinet thermostatique
+ 5
+
+
+ Réseau de chaleur
+ 6
+
+
+
+
+ 1
+
+
+ Murs
+ 1
+ type de mesure
+ 1
+
+
+
+
+
+
+ plan
+ 1
+
+
+
+
+ Ne pas obstruer les entrées d'air. Les nettoyer à l'aide d'un chiffon sec -> 1 fois par an
+Nettoyer les bouches d'extraction -> tous les 2 ans
+Entretien des conduits par un professionnel -> tous les 3 à 5 ans
+Veiller à ouvrir les fenêtres de chaque pièce très régulièrement afin de garantir la qualité de l'air intérieur
+
+ 1
+ VMC
+
+
+ Entretien obligatoire par un professionnel -> tous les 2 ans
+Programmer la température de chauffage en fonction de votre présence. Baisser la température la nuit.
+
+ 7
+ Pompe à chaleur
+
+
+ Dépoussiérer les radiateurs régulièrement.
+
+ 3
+ Radiateurs
+
+
+ Faire désembouer le circuit de chauffage par un professionnel -> tous les 10 ans
+Veiller au bon équilibrage de l'installation de chauffage.
+
+ 6
+ Circuit de chauffage
+
+
+ Nettoyer les ampoules et les luminaires.
+
+ 4
+ Eclairage
+
+
+
+
+
+ 1
+ 134
+ 22
+ 58636
+ 79332
+
+
+ Sans
+ 4
+
+ -
+
+
+ Isolation des murs extérieurs par l'extérieur
+En construction récente, ne jamais isoler un mur humide. Avant de poser un isolant, traiter au préalable le problème d'humidité.
+
+En construction ancienne, ne pas poser de matériau étanche ou hydrophile au risque de menacer sa durée de vie, utiliser des isolants perméables à la vapeur d'eau (ou capillaires). Supprimer les travaux antérieurs inadaptés (en cas de prolifération d'algues et de moisissures ou si la conductivité thermique des isolants présents est dégradée).
+
+Ne jamais ventiler la lame d'air entre l'isolant et le mur extérieur par des orifices dans l'isolant donnant sur l'intérieur.
+
+Pour bénéficier de MaPrimRénov' choisir un isolant avec R= 3,7 m².K/W.
+
+
+ 1
+
+ R >= 3,7 m2.K/W
+
+
+ Sans
+ 3
+
+ -
+
+
+ Sans
+ 2
+
+ -
+
+
+ Mise en place VMC Hygro à extract.et entrées d'air hygro(B)
+Eviter pour les constructions anciennes car il y a un risque de contrevenir à la bonne gestion de la vapeur d'eau du sol vers les murs et l'air. Cela risque de créer des problèmes d'humidité et des contre-performances thermiques des maçonneries.
+
+ Prévoir des entrées d'air dans les menuiseries.
+
+ Calfeutrer les défauts d'étanchéité après avoir mis en place des entrées d'air.
+
+
+ 8
+
+ -
+
+
+ Sans
+ 5
+
+ -
+
+
+ Sans
+ 6
+
+ -
+
+
+ Sans
+ 6
+
+ -
+
+
+ Sans
+ 6
+
+ -
+
+
+
+
+ 3
+ 77
+ 9
+ 105386
+ 142582
+
+
+ Sans
+ 4
+
+ -
+
+
+ Isolation des murs extérieurs par l'extérieur
+En construction récente, ne jamais isoler un mur humide. Avant de poser un isolant, traiter au préalable le problème d'humidité.
+
+En construction ancienne, ne pas poser de matériau étanche ou hydrophile au risque de menacer sa durée de vie, utiliser des isolants perméables à la vapeur d'eau (ou capillaires). Supprimer les travaux antérieurs inadaptés (en cas de prolifération d'algues et de moisissures ou si la conductivité thermique des isolants présents est dégradée).
+
+Ne jamais ventiler la lame d'air entre l'isolant et le mur extérieur par des orifices dans l'isolant donnant sur l'intérieur.
+
+Pour bénéficier de MaPrimRénov' choisir un isolant avec R= 3,7 m².K/W.
+
+
+ 1
+
+ -
+
+
+ Sans
+ 3
+
+ -
+
+
+ Sans
+ 2
+
+ -
+
+
+ Mise en place VMC Hygro à extract.et entrées d'air hygro(B)
+Eviter pour les constructions anciennes car il y a un risque de contrevenir à la bonne gestion de la vapeur d'eau du sol vers les murs et l'air. Cela risque de créer des problèmes d'humidité et des contre-performances thermiques des maçonneries.
+
+ Prévoir des entrées d'air dans les menuiseries.
+
+ Calfeutrer les défauts d'étanchéité après avoir mis en place des entrées d'air.
+
+
+ 8
+
+ -
+
+
+ Sans
+ 5
+
+ -
+
+
+ Installation d'un chauffe-eau thermodynamique
+
+
+
+ 6
+
+ -
+
+
+ Sans
+ 6
+
+ -
+
+
+ Sans
+ 6
+
+ -
+
+
+
+
+ -
+
+
\ No newline at end of file
diff --git a/test/fixtures/2431E1275871H.xml b/test/fixtures/2431E1275871H.xml
new file mode 100644
index 0000000..e10f371
--- /dev/null
+++ b/test/fixtures/2431E1275871H.xml
@@ -0,0 +1,4205 @@
+
+ 2431E1275871H
+ ACTIF
+
+ 2.3
+ 2024-03-29
+ 2024-04-09
+ 1
+ log 2.48 (bld 324.5302)
+
+ 15257
+ 4.1.1
+ 3cl_tribu_1.4.25.1
+
+
+
+
+ 14 rue Notre Dame
+ 31000
+ TOULOUSE
+ 14 rue Notre Dame 31000 TOULOUSE
+ 14 rue Notre Dame 31000 TOULOUSE
+ 2
+ 2024-03-29
+
+
+
+
+
+
+
+
+
+
+ 1980
+ 4
+ 6
+ 2
+ 170
+ 2
+ 2.4
+ 8
+
+
+ 6
+ 1
+ 0
+
+
+
+ 0
+ 0
+ 0
+ 3
+
+
+
+
+ Murs Extérieur
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+ 220
+ 5
+ 9.72
+ 9.72
+ 15
+ 2
+ 9.72
+ 6.456
+ 62
+ 20
+ 10
+ 2
+ 0
+ 2
+ 1
+ 15
+ 2
+
+
+ 0.65
+ 0.84
+ 2
+
+
+
+
+ Mur Extérieur
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+ 1
+ 1
+ 2
+ 33.12
+ 26.3
+ 62
+ 20
+ 10
+ 2
+ 0
+ 2
+ 1
+ 15
+ 2
+
+
+ 1
+ 0.84
+ 2
+
+
+
+
+ Mur Extérieur
+ 42be63bf-fe4e-4ea2-8c9e-9ea6ac3ff374
+ 1
+ 1
+ 4
+ 36.24
+ 35.7
+ 62
+ 20
+ 10
+ 2
+ 0
+ 2
+ 1
+ 15
+ 2
+
+
+ 1
+ 0.84
+ 2
+
+
+
+
+ Mur Extérieur
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 1
+ 1
+ 1
+ 32.4
+ 23.381
+ 62
+ 20
+ 10
+ 2
+ 0
+ 2
+ 1
+ 15
+ 2
+
+
+ 1
+ 0.84
+ 2
+
+
+
+
+ Mur Extérieur
+ 13fea784-ed66-416a-8c86-2db533db3b94
+ 1
+ 1
+ 4
+ 9.6
+ 7.968
+ 62
+ 20
+ 10
+ 2
+ 0
+ 2
+ 1
+ 15
+ 2
+
+
+ 1
+ 0.84
+ 2
+
+
+
+
+
+
+ Plancher
+ 4c71a371-f7c3-43ab-a117-22147620a88f
+ 44
+ 4
+ 6.5
+ 6.5
+ 21
+ 6.5
+ 10
+ 10
+ 2
+ 1
+ 15
+ 2
+ 0
+
+
+ 0.95
+ 0.84
+ 0.84
+ 1.6
+
+
+
+
+ Plancher
+ 9a5ea8f2-f9f8-4c68-aa71-556733fae1a4
+ 3
+ 3
+ 75
+ 9
+ 9
+ 2
+ 1
+ 15
+ 2
+ 1
+ 37
+ 75
+ 0.3705
+
+
+ 1
+ 0.84
+ 0.3705
+ 2
+
+
+
+
+
+
+ Plafond
+ 4bc22b47-7ef5-4b7e-b38d-fa9f13a8c23c
+ 1
+ 1
+ 70
+ 12
+ 12
+ 2
+ 3
+ 7
+ 33
+ 8
+
+
+ 1
+ 0.23
+ 2.5
+
+
+
+
+
+
+ Fenêtre
+ d473023c-6007-4695-a15a-dd264ea490a3
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+ 1
+ 1
+ 2.2
+ 1
+ 27
+ 2
+ 3
+ 2
+ 18
+ 0
+ 1
+ 545
+ 3
+ 4
+ 0
+ 1
+ 21
+ 2
+ 0
+ 0
+ 0
+ 5
+ 90
+ 2
+ 2
+ 19
+
+
+ 1
+ 2.6
+ 2.8
+ 2.5
+ 2.5
+ 0.47
+ 1
+ 1
+
+
+
+
+ Fenêtre
+ f50e2d62-3e8a-4c05-9b97-f056805a0b52
+ 42be63bf-fe4e-4ea2-8c9e-9ea6ac3ff374
+ 1
+ 1
+ 0.54
+ 1
+ 21
+ 2
+ 3
+ 2
+ 8
+ 0
+ 1
+ 548
+ 3
+ 4
+ 0
+ 1
+ 0
+ 0
+ 0
+ 5
+ 90
+ 2
+ 4
+ 19
+
+
+ 1
+ 2.9
+ 3
+ 3
+ 0.47
+ 1
+ 1
+
+
+
+
+ Fenêtre
+ 0810a305-cf7e-4971-9aa7-496b37457e87
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 1
+ 1
+ 0.72
+ 2
+ 21
+ 2
+ 3
+ 2
+ 8
+ 0
+ 1
+ 548
+ 3
+ 4
+ 0
+ 1
+ 0
+ 0
+ 0
+ 5
+ 90
+ 2
+ 1
+ 19
+
+
+ 1
+ 2.9
+ 3
+ 3
+ 0.47
+ 1
+ 1
+
+
+
+
+ Fenêtre
+ 32d6f631-9049-42ae-be00-e95a046d2bfe
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 1
+ 1
+ 2.479
+ 1
+ 25
+ 2
+ 3
+ 2
+ 15
+ 0
+ 1
+ 65
+ 6
+ 5
+ 0
+ 3
+ 143
+ 4
+ 0
+ 0
+ 0
+ 5
+ 140
+ 2
+ 1
+ 19
+
+
+ 1
+ 2.6
+ 3.2
+ 2.6
+ 2.6
+ 0.52
+ 1
+ 1
+
+
+
+
+ Fenêtre
+ c34e4113-2edf-48b8-abe6-5cc413344c3c
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 1
+ 1
+ 2.62
+ 2
+ 27
+ 2
+ 3
+ 2
+ 18
+ 0
+ 1
+ 545
+ 3
+ 4
+ 0
+ 3
+ 139
+ 4
+ 0
+ 0
+ 0
+ 5
+ 90
+ 2
+ 1
+ 19
+
+
+ 1
+ 2.6
+ 2.8
+ 2.3
+ 2.3
+ 0.47
+ 1
+ 1
+
+
+
+
+ Fenêtre
+ aee4742d-d13a-4366-828d-bb61586efbf3
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+ 1
+ 1
+ 4.62
+ 4
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 530
+ 3
+ 4
+ 0
+ 1
+ 9
+ 2
+ 0
+ 0
+ 0
+ 5
+ 91
+ 2
+ 2
+ 19
+
+
+ 1
+ 1.1
+ 1.6
+ 1.5
+ 1.5
+ 0.4
+ 1
+ 1
+
+
+
+
+
+
+ Porte
+ 5edc5353-e30d-4040-9ee9-8007b41fe2bf
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+ 220
+ 5
+ 9.72
+ 9.72
+ 15
+ 1.632
+ 1
+ 1
+ 5
+ 1
+ 5
+ 0
+ 0
+ 2
+
+
+ 3.5
+ 0.65
+
+
+
+
+ Porte
+ f9a7cef3-d015-4453-bbb9-397edcdb73a9
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+ 220
+ 5
+ 9.72
+ 9.72
+ 15
+ 1.632
+ 1
+ 1
+ 1
+ 1
+ 5
+ 0
+ 0
+ 2
+
+
+ 3.5
+ 0.65
+
+
+
+
+ Porte
+ b118341f-3a09-4bbb-97ba-b768803b1c16
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 1
+ 1
+ 1.6
+ 1
+ 1
+ 1
+ 1
+ 5
+ 0
+ 0
+ 2
+
+
+ 3.5
+ 1
+
+
+
+
+ Porte
+ 9e1d8f7b-e54c-4cc8-9916-47a982f911e2
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 1
+ 1
+ 1.6
+ 1
+ 1
+ 1
+ 1
+ 5
+ 0
+ 0
+ 2
+
+
+ 3.5
+ 1
+
+
+
+
+ Porte
+ b44f259c-f698-4936-9d74-609f15c27936
+ 13fea784-ed66-416a-8c86-2db533db3b94
+ 1
+ 1
+ 1.632
+ 11
+ 1
+ 15
+ 1
+ 5
+ 0
+ 0
+ 2
+
+
+ 1.5
+ 1
+
+
+
+
+
+
+
+ Plancher -Murs Extérieur
+ 138aca60-e572-4e26-af8c-508a22cdb4c7
+ 9a5ea8f2-f9f8-4c68-aa71-556733fae1a4
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+ 7
+ 2.45
+ 1
+ 1
+ 1
+
+
+ 0
+
+
+
+
+ Plancher -Mur Extérieur
+ 2b5ad02a-5dda-46bd-96b5-d650007290d1
+ 9a5ea8f2-f9f8-4c68-aa71-556733fae1a4
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+ 7
+ 13.8
+ 1
+ 1
+ 1
+
+
+ 0.71
+
+
+
+
+ Plancher -Mur Extérieur
+ dcb2d145-b624-4f3f-9f0f-702d08a264a8
+ 9a5ea8f2-f9f8-4c68-aa71-556733fae1a4
+ 42be63bf-fe4e-4ea2-8c9e-9ea6ac3ff374
+ 7
+ 15.1
+ 1
+ 1
+ 1
+
+
+ 0.71
+
+
+
+
+ Plancher -Mur Extérieur
+ 8232d28d-8f0e-4ee9-8efd-b9029fdbd0e8
+ 9a5ea8f2-f9f8-4c68-aa71-556733fae1a4
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 7
+ 11.9
+ 1
+ 1
+ 1
+
+
+ 0.71
+
+
+
+
+ Plancher -Mur Extérieur
+ 7e0a715d-0000-4fe5-bad5-5182612908c5
+ 9a5ea8f2-f9f8-4c68-aa71-556733fae1a4
+ 13fea784-ed66-416a-8c86-2db533db3b94
+ 7
+ 3.2
+ 1
+ 1
+ 1
+
+
+ 0.71
+
+
+
+
+ Murs Extérieur (vers le haut)-
+ 9f950b14-60ed-4baf-8d8e-8349a6609d60
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+
+ 30
+ 2.45
+ 1
+ 2
+ 0.5
+
+
+ 0
+
+
+
+
+ Mur Extérieur (vers le haut)-
+ 3723ecb1-2152-4e72-9918-d60c0075727b
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+
+ 30
+ 13.8
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Mur Extérieur (vers le haut)-
+ dbdff327-934b-4709-b940-b2eed5846cb3
+ 42be63bf-fe4e-4ea2-8c9e-9ea6ac3ff374
+
+ 30
+ 15.1
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Mur Extérieur (vers le haut)-
+ 1322d6f2-e65a-4a3a-a3aa-d865f3474744
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+
+ 30
+ 11.9
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Mur Extérieur (vers le haut)-
+ 308d5d13-5829-43fa-8dd1-1ee9f28a8194
+ 13fea784-ed66-416a-8c86-2db533db3b94
+
+ 30
+ 3.2
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Murs Extérieur (vers le bas)-
+ ec9fb506-d31a-445b-95d2-91e4e40e0ed6
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+
+ 30
+ 2.45
+ 1
+ 2
+ 0.5
+
+
+ 0
+
+
+
+
+ Mur Extérieur (vers le bas)-
+ 4e35aa32-d242-4a86-bf05-97895a6804da
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+
+ 30
+ 13.8
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Mur Extérieur (vers le bas)-
+ 63d0387e-8c09-4f98-a073-ef9939a9408e
+ 42be63bf-fe4e-4ea2-8c9e-9ea6ac3ff374
+
+ 30
+ 15.1
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Mur Extérieur (vers le bas)-
+ 5d13f196-8915-43a7-9504-c229ba02053e
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+
+ 30
+ 11.9
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Mur Extérieur (vers le bas)-
+ 590a515d-6cf7-43d5-b7ab-7ef7c8dd996b
+ 13fea784-ed66-416a-8c86-2db533db3b94
+
+ 30
+ 3.2
+ 1
+ 2
+ 0.5
+
+
+ 0.92
+
+
+
+
+ Fenêtre -Mur Extérieur
+ bb2c19b1-0628-4200-b018-0deb010bc170
+ d473023c-6007-4695-a15a-dd264ea490a3
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+ 87
+ 6.4
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Fenêtre -Mur Extérieur
+ 9d5dfcc3-52e3-44fb-8b2b-d04aac201f26
+ f50e2d62-3e8a-4c05-9b97-f056805a0b52
+ 42be63bf-fe4e-4ea2-8c9e-9ea6ac3ff374
+ 87
+ 3
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Fenêtre -Mur Extérieur
+ 3ce3e59b-2123-4749-bcbe-1a97679a56f4
+ 0810a305-cf7e-4971-9aa7-496b37457e87
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 87
+ 4.8
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Fenêtre -Mur Extérieur
+ 266ab02a-08bd-4da3-9e0d-676875f2c8af
+ 32d6f631-9049-42ae-be00-e95a046d2bfe
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 87
+ 6.38
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Fenêtre -Mur Extérieur
+ d754d0a4-9112-4492-a2dd-2848e7fdb317
+ c34e4113-2edf-48b8-abe6-5cc413344c3c
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 87
+ 9.24
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Fenêtre -Mur Extérieur
+ 20c3f380-f750-4a3a-9ec3-253f35cea54e
+ aee4742d-d13a-4366-828d-bb61586efbf3
+ db3fb5c9-f20f-42ef-9ac6-5e5312e8b6c0
+ 87
+ 18.8
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Porte -Murs Extérieur
+ 84f62465-7758-411c-a4a7-0383bf2b4fb0
+ 5edc5353-e30d-4040-9ee9-8007b41fe2bf
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+ 87
+ 4.88
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Porte -Murs Extérieur
+ 831f9db8-533f-4452-9963-aa25d27b00dd
+ f9a7cef3-d015-4453-bbb9-397edcdb73a9
+ c6e41535-8038-49c1-af88-0ba6166ca37d
+ 87
+ 4.88
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Porte -Mur Extérieur
+ 1c3b92d4-b014-4d4d-994c-8d727ac5a019
+ b118341f-3a09-4bbb-97ba-b768803b1c16
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 87
+ 4.8
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Porte -Mur Extérieur
+ 36b5a855-1fda-47e5-ab35-5d7b1cf6d648
+ 9e1d8f7b-e54c-4cc8-9916-47a982f911e2
+ 0e20c1b3-6cc8-430d-af30-a50760fab317
+ 87
+ 4.8
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+ Porte -Mur Extérieur
+ cf385af4-dcfa-4740-8506-8dbca7539ea5
+ b44f259c-f698-4936-9d74-609f15c27936
+ 13fea784-ed66-416a-8c86-2db533db3b94
+ 87
+ 4.88
+ 1
+ 5
+ 1
+
+
+ 0
+
+
+
+
+
+
+
+ 170
+
+ 0d73dffa-be41-4ace-b072-08a42a985786
+ 0
+ 3
+ 1
+ 5
+ 5
+ 0
+
+
+ 0
+ 1.5
+ 1
+ 1.27809183910363
+ 86.7
+
+
+
+
+
+
+
+ Chauffe-eau vertical Electrique
+ Ecs_420b09c1-cb56-4967-9219-4c8774c7f931
+ 1
+ 1
+ 4
+ 1
+ 170
+ 8
+ 8
+ 2
+ 1
+ 1
+
+
+ 0.93
+ 716544.36175
+ 1010839.36746875
+ 8089.47090416667
+ 10621.0408458333
+
+
+
+
+ Chauffe-eau vertical
+ E420b09c1-cb56-4967-9219-4c8774c7f931
+ 70
+ 2
+ 1
+ 1
+ 3
+ 2
+ 1
+ 50
+ 1
+
+
+ 1
+ 1
+ 8089.47090416667
+ 10621.0408458333
+ 0.761956194624774
+
+
+
+
+
+
+
+
+ Chauffage sans solaire
+ Installation 1
+ 56.6666683554649
+ 3
+ 2.66666674613953
+ 2
+ 1
+ 1
+ 4
+
+
+ 3092.89251040572
+ 4038.27552955298
+ 3009.52137652857
+ 3929.42091896613
+
+
+
+
+ Convecteur électrique NF**
+ Emet_3d459af5-23aa-407a-87f4-809963639300
+ 56.6666683554649
+ 1
+ 1
+ 1
+ 1
+ 102
+ 1
+ 0
+ 2
+ 1
+ 1
+ 1
+
+
+ 0.9
+ 0.95
+ 1
+ 0.99
+
+
+
+
+
+
+ Convecteur électrique NF**
+ Gbaaaa6fd-e3ed-4b6c-9ca0-d0abcdc5b348
+ 98
+ 1
+ 1
+ 1
+ 29
+ 1
+ 1
+
+
+ 1
+ 3009.52137652857
+ 3929.42091896613
+
+
+
+
+
+
+ Chauffage sans solaire
+ Installation 2
+ 113.33333671093
+ 5
+ 5.33333349227905
+ 2
+ 1
+ 1
+ 4
+
+
+ 6185.78502081144
+ 8076.55105910596
+ 5632.94149971097
+ 7354.72369025275
+
+
+
+
+ Radiateur électrique NF**
+ Emet_20abccd7-3144-407d-ba1d-68a5f222d720
+ 113.33333671093
+ 2
+ 1
+ 2
+ 3
+ 138
+ 4
+ 0
+ 2
+ 1
+ 1
+ 1
+
+
+ 0.86
+ 0.97
+ 1
+ 0.99
+
+
+
+
+
+
+ Radiateur électrique NF**
+ G679a0024-874e-44c3-b004-662718832e16
+ 100
+ 1
+ 1
+ 1
+ 29
+ 1
+ 1
+
+
+ 1
+ 5632.94149971097
+ 7354.72369025275
+
+
+
+
+
+
+
+ 1.27809183910363
+ 86.7
+ 87.9780918391036
+ 81.938136
+ 32.9745
+ 16.1
+ 28.6814
+ 21.0736
+ 71.72
+ 340.465091839104
+
+
+ 52.882408
+ 0
+ 0
+ 2170447.87422
+ 6400538.43392857
+ 0.410684460339341
+ 0.367065280698569
+ 156642.486884263
+ 229928.568889659
+ 526203.219606164
+ 0
+ 0
+ 9.6875
+ 542.5
+ 765.3125
+ 9278.67725469103
+ 12114.826227609
+ 5732.354894
+ 8086.71493975
+ 0
+ 0
+
+
+ 8642.46287623954
+ 11284.1446092189
+ 8089.47090416667
+ 10621.0408458333
+ 335.4372
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 1027.548
+ 1027.548
+ 0
+ 0
+ 18094.9189804062
+ 106.440699884742
+
+
+ 19877.6646153509
+ 25953.5326012034
+ 18605.7830795833
+ 24428.3939454167
+ 771.505544005108
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 2363.36035100269
+ 2363.36035100269
+ 0
+ 0
+ 41618.3136549343
+ 244.813609734907
+ D
+
+
+ 682.75459864591
+ 891.447465156125
+ 525.815589484032
+ 690.367629656632
+ 23.1451662201852
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 65.7630751235783
+ 65.7630751235783
+ 0
+ 0
+ 1297.1
+ 7.63
+ B
+
+
+ 1785
+ 2186
+ 1671
+ 2057
+ 69
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 212
+ 212
+ 0
+ 0
+ 3737
+
+
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+
+
+
+ 8642.46287623954
+ 8089.47090416667
+ 18094.9189804062
+ 1
+ 682.75459864591
+ 525.815589484032
+ 1297.47842947371
+ 1785
+ 1671
+ 3737
+
+
+
+ 0.881587829651433
+ 4
+ 4
+ 2
+ 2
+ 3
+
+
+
+
+
+
+ Logement 1 Appartement dont le plancher bas donne sur un terre-plein
+ 1
+ 1
+ 13
+
+
+ Logement 7 Appartement situé entièrement sous une toiture (combles, terrasse, local non
+ chauffé, mixte combles / terrasse)
+
+ 3
+ 1
+ 25
+
+
+ Logement 6 Appartement situé entièrement sous une toiture (combles, terrasse, local non
+ chauffé, mixte combles / terrasse)
+
+ 3
+ 1
+ 25
+
+
+ Logement 2 Appartement dont le plancher bas donne sur un terre-plein
+ 1
+ 1
+ 11
+
+
+ Logement 5 Appartement situé entièrement sous une toiture (combles, terrasse, local non
+ chauffé, mixte combles / terrasse)
+
+ 3
+ 1
+ 22
+
+
+
+
+
+
+ Mur Extérieur Ouest Briques creuses donnant sur Extérieur, isolation inconnue
+ Mur Extérieur Nord Briques creuses donnant sur Extérieur, isolation inconnue
+ Mur Extérieur Sud Briques creuses donnant sur Extérieur, isolation inconnue
+
+ 1
+
+
+ Plancher Dalle béton donnant sur Vide-sanitaire, isolation inconnue
+ Plancher Bois sur solives bois donnant sur Local non chauffé, isolation inconnue
+
+ 2
+
+
+ Plafond Combles aménagés sous rampants donnant sur Extérieur, isolé
+ 3
+
+
+ Fenêtres coulissantes, Menuiserie métallique à rupture de pont thermique - double vitrage
+ vertical (e = 15 mm) avec Fermeture
+ Fenêtres battantes, Menuiserie Bois - double vitrage vertical (e = 18 mm) avec Fermeture
+ Fenêtres battantes, Menuiserie Bois VIR - double vitrage vertical (e = 20 mm) avec Fermeture
+ Fenêtres battantes, Menuiserie Bois - double vitrage vertical (e = 8 mm)
+ Porte PVC Opaque pleine
+ Porte Bois Opaque pleine
+ Porte isolée avec double vitrage
+
+ 4
+
+
+ Radiateur électrique NF** Electrique, installation en 2022, individuel
+ Convecteur électrique NF** Electrique, installation en 2010, individuel
+
+ 5
+
+
+ Chauffe-eau vertical Electrique installation en 2020, individuel, production par
+ semi-accumulation
+
+ 6
+
+
+ VMC SF Auto réglable de 2001 à 2012 et Ventilation naturelle avec des grilles
+ 8
+
+
+ Convecteur électrique NF** :
+ avec régulation pièce par pièce, absence d'équipements d'intermittence
+ Radiateur électrique NF** :
+ avec régulation pièce par pièce, intermittence par pièce avec minimum de température
+
+ 9
+
+
+
+
+ 1
+
+
+ Surface
+ 6.46 m²
+
+ 2
+
+
+ Matériau mur
+ Briques creuses
+
+ 2
+
+
+ Epaisseur mur
+ 20 cm
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Bâtiment construit en matériaux anciens
+ Non
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Type de local non chauffé adjacent
+ Circulations communes avec ouverture directe sur l'extérieur
+
+ 2
+
+
+ Surface Aiu
+ 9.72 m²
+
+ 2
+
+
+ Surface Aue
+ 9.72 m²
+
+ 2
+
+
+ Etat isolation des parois du local non chauffé
+ Oui
+
+ 1
+
+
+ Doublage
+ absence de doublage
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface
+ 26.3 m²
+
+ 2
+
+
+ Matériau mur
+ Briques creuses
+
+ 2
+
+
+ Epaisseur mur
+ 20 cm
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Bâtiment construit en matériaux anciens
+ Non
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Doublage
+ absence de doublage
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface
+ 35.7 m²
+
+ 2
+
+
+ Matériau mur
+ Briques creuses
+
+ 2
+
+
+ Epaisseur mur
+ 20 cm
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Bâtiment construit en matériaux anciens
+ Non
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Doublage
+ absence de doublage
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface
+ 23.38 m²
+
+ 2
+
+
+ Matériau mur
+ Briques creuses
+
+ 2
+
+
+ Epaisseur mur
+ 20 cm
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Bâtiment construit en matériaux anciens
+ Non
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Doublage
+ absence de doublage
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface
+ 7.97 m²
+
+ 2
+
+
+ Matériau mur
+ Briques creuses
+
+ 2
+
+
+ Epaisseur mur
+ 20 cm
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Bâtiment construit en matériaux anciens
+ Non
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Doublage
+ absence de doublage
+
+ 2
+
+
+
+
+ 2
+
+
+ Surface
+ 6.5 m²
+
+ 2
+
+
+ Type de plancher bas
+ Bois sur solives bois
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Type d’adjacence
+ Autres dépendances
+
+ 2
+
+
+ Surface Aiu
+ 6.5 m²
+
+ 2
+
+
+ Surface Aue
+ 6.5 m²
+
+ 2
+
+
+ Etat isolation des parois du local non chauffé
+ Non
+
+ 1
+
+
+
+
+ 2
+
+
+ Surface
+ 75 m²
+
+ 2
+
+
+ Type de plancher bas
+ Dalle béton
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Inconnue
+
+ 2
+
+
+ Périmètre plancher déperditif sur terre-plein, vide sanitaire ou sous-sol non chauffé
+
+ 37 m
+
+ 2
+
+
+ Surface plancher sur terre-plein, vide sanitaire ou sous-sol non chauffé
+ 75 m²
+
+ 2
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+ Type d’adjacence
+ Vide-sanitaire
+
+ 2
+
+
+
+
+ 3
+
+
+ Surface
+ 70 m²
+
+ 2
+
+
+ Type
+ Combles aménagés sous rampants
+
+ 2
+
+
+ Isolation : oui / non / inconnue
+ Oui
+
+ 2
+
+
+ Année isolation
+ 2001 à 2005
+
+ 1
+
+
+ Inertie
+ Légère
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies
+ 2.2 m²
+
+ 2
+
+
+ Type de vitrage
+ Double vitrage vertical
+
+ 2
+
+
+ Epaisseur lame air
+ 18 mm
+
+ 2
+
+
+ Présence couche peu émissive
+ Non
+
+ 2
+
+
+ Gaz de remplissage
+ Argon ou Krypton
+
+ 2
+
+
+ Double fenêtre
+ Non
+
+ 2
+
+
+ Inclinaison vitrage
+ Verticale (Inclinaison ≥ 75°)
+
+ 2
+
+
+ Type menuiserie
+ Menuiserie Bois
+
+ 2
+
+
+ Positionnement de la menuiserie
+ Nu intérieur
+
+ 2
+
+
+ Type ouverture
+ Fenêtres battantes
+
+ 2
+
+
+ Type volets
+ Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout
+ métal, volets battants ou persiennes avec ajours fixes
+
+
+ 2
+
+
+ Orientation des baies
+ Nord
+
+ 2
+
+
+ Type de masque proches
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains
+ Absence de masque lointain
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies
+ 0.54 m²
+
+ 2
+
+
+ Type de vitrage
+ Double vitrage vertical
+
+ 2
+
+
+ Epaisseur lame air
+ 8 mm
+
+ 2
+
+
+ Présence couche peu émissive
+ Non
+
+ 2
+
+
+ Gaz de remplissage
+ Argon ou Krypton
+
+ 2
+
+
+ Double fenêtre
+ Non
+
+ 2
+
+
+ Inclinaison vitrage
+ Verticale (Inclinaison ≥ 75°)
+
+ 2
+
+
+ Type menuiserie
+ Menuiserie Bois
+
+ 2
+
+
+ Positionnement de la menuiserie
+ Nu intérieur
+
+ 2
+
+
+ Type ouverture
+ Fenêtres battantes
+
+ 2
+
+
+ Type volets
+ Sans
+
+ 2
+
+
+ Orientation des baies
+ Ouest
+
+ 2
+
+
+ Type de masque proches
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains
+ Absence de masque lointain
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies
+ 0.72 m²
+
+ 2
+
+
+ Type de vitrage
+ Double vitrage vertical
+
+ 2
+
+
+ Epaisseur lame air
+ 8 mm
+
+ 2
+
+
+ Présence couche peu émissive
+ Non
+
+ 2
+
+
+ Gaz de remplissage
+ Argon ou Krypton
+
+ 2
+
+
+ Double fenêtre
+ Non
+
+ 2
+
+
+ Inclinaison vitrage
+ Verticale (Inclinaison ≥ 75°)
+
+ 2
+
+
+ Type menuiserie
+ Menuiserie Bois
+
+ 2
+
+
+ Positionnement de la menuiserie
+ Nu intérieur
+
+ 2
+
+
+ Type ouverture
+ Fenêtres battantes
+
+ 2
+
+
+ Type volets
+ Sans
+
+ 2
+
+
+ Orientation des baies
+ Sud
+
+ 2
+
+
+ Type de masque proches
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains
+ Absence de masque lointain
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies
+ 2.48 m²
+
+ 2
+
+
+ Type de vitrage
+ Double vitrage vertical
+
+ 2
+
+
+ Epaisseur lame air
+ 15 mm
+
+ 2
+
+
+ Présence couche peu émissive
+ Non
+
+ 2
+
+
+ Gaz de remplissage
+ Argon ou Krypton
+
+ 2
+
+
+ Double fenêtre
+ Non
+
+ 2
+
+
+ Inclinaison vitrage
+ Verticale (Inclinaison ≥ 75°)
+
+ 2
+
+
+ Type menuiserie
+ Menuiserie métallique à rupture de pont thermique
+
+ 2
+
+
+ Positionnement de la menuiserie
+ Nu intérieur
+
+ 2
+
+
+ Type ouverture
+ Fenêtres coulissantes
+
+ 2
+
+
+ Type volets
+ Volet roulant PVC ou bois (épaisseur tablier ≤ 12mm)
+
+ 2
+
+
+ Orientation des baies
+ Sud
+
+ 2
+
+
+ Type de masque proches
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains
+ Absence de masque lointain
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies
+ 2.62 m²
+
+ 2
+
+
+ Type de vitrage
+ Double vitrage vertical
+
+ 2
+
+
+ Epaisseur lame air
+ 18 mm
+
+ 2
+
+
+ Présence couche peu émissive
+ Non
+
+ 2
+
+
+ Gaz de remplissage
+ Argon ou Krypton
+
+ 2
+
+
+ Double fenêtre
+ Non
+
+ 2
+
+
+ Inclinaison vitrage
+ Verticale (Inclinaison ≥ 75°)
+
+ 2
+
+
+ Type menuiserie
+ Menuiserie Bois
+
+ 2
+
+
+ Positionnement de la menuiserie
+ Nu intérieur
+
+ 2
+
+
+ Type ouverture
+ Fenêtres battantes
+
+ 2
+
+
+ Type volets
+ Volet roulant PVC ou bois (épaisseur tablier ≤ 12mm)
+
+ 2
+
+
+ Orientation des baies
+ Sud
+
+ 2
+
+
+ Type de masque proches
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains
+ Absence de masque lointain
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies
+ 4.62 m²
+
+ 2
+
+
+ Type de vitrage
+ Double vitrage vertical
+
+ 2
+
+
+ Epaisseur lame air
+ 20 mm
+
+ 2
+
+
+ Présence couche peu émissive
+ Oui
+
+ 2
+
+
+ Gaz de remplissage
+ Argon ou Krypton
+
+ 2
+
+
+ Double fenêtre
+ Non
+
+ 2
+
+
+ Inclinaison vitrage
+ Verticale (Inclinaison ≥ 75°)
+
+ 2
+
+
+ Type menuiserie
+ Menuiserie Bois
+
+ 2
+
+
+ Positionnement de la menuiserie
+ Nu intérieur
+
+ 2
+
+
+ Type ouverture
+ Fenêtres battantes
+
+ 2
+
+
+ Type volets
+ Jalousie accordéon, fermeture à lames orientables y compris les vénitiens extérieurs tout
+ métal, volets battants ou persiennes avec ajours fixes
+
+
+ 2
+
+
+ Orientation des baies
+ Nord
+
+ 2
+
+
+ Type de masque proches
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains
+ Absence de masque lointain
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 5
+
+
+ Type de menuiserie
+ PVC
+
+ 2
+
+
+ Type de porte
+ Opaque pleine
+
+ 2
+
+
+ Surface
+ 1.63 m²
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 5
+
+
+ Type de menuiserie
+ Bois
+
+ 2
+
+
+ Type de porte
+ Opaque pleine
+
+ 2
+
+
+ Surface
+ 1.63 m²
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 5
+
+
+ Type de menuiserie
+ Bois
+
+ 2
+
+
+ Type de porte
+ Opaque pleine
+
+ 2
+
+
+ Surface
+ 1.6 m²
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 5
+
+
+ Type de menuiserie
+ Bois
+
+ 2
+
+
+ Type de porte
+ Opaque pleine
+
+ 2
+
+
+ Surface
+ 1.6 m²
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 5
+
+
+ Type de porte
+ Porte isolée avec double vitrage
+
+ 2
+
+
+ Surface
+ 1.63 m²
+
+ 2
+
+
+ Présence de joints
+ Non
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher bas - Mur
+
+ 2
+
+
+ Type isolation
+ Plancher : ITE
+ Murs Extérieur : ITI
+
+
+ 1
+
+
+ Longueur du pont thermique
+ 2.45 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher bas - Mur
+
+ 2
+
+
+ Type isolation
+ Plancher : ITE
+ Mur Extérieur : ITI
+
+
+ 1
+
+
+ Longueur du pont thermique
+ 13.8 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher bas - Mur
+
+ 2
+
+
+ Type isolation
+ Plancher : ITE
+ Mur Extérieur : ITI
+
+
+ 1
+
+
+ Longueur du pont thermique
+ 15.1 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher bas - Mur
+
+ 2
+
+
+ Type isolation
+ Plancher : ITE
+ Mur Extérieur : ITI
+
+
+ 1
+
+
+ Longueur du pont thermique
+ 11.9 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher bas - Mur
+
+ 2
+
+
+ Type isolation
+ Plancher : ITE
+ Mur Extérieur : ITI
+
+
+ 1
+
+
+ Longueur du pont thermique
+ 3.2 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 2.45 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 13.8 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 15.1 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 11.9 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 3.2 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 2.45 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 13.8 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 15.1 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 11.9 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Plancher intermédiaire lourd - Mur lourd
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 3.2 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 6.4 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 3 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 4.8 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 6.38 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 9.24 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 18.8 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 4.88 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 4.88 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 4.8 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 4.8 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique
+ Menuiseries - Mur
+
+ 2
+
+
+ Type isolation
+ ITI
+
+ 1
+
+
+ Longueur du pont thermique
+ 4.88 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp
+ 5 cm
+
+ 2
+
+
+ Retour isolation autour menuiserie
+ Non
+
+ 2
+
+
+ Position menuiseries
+ Nu intérieur
+
+ 2
+
+
+
+
+ 7
+
+
+ Type d’installation de chauffage
+ Installation de chauffage sans solaire
+
+ 2
+
+
+ Type générateur
+ Convecteur électrique NF**
+
+ 2
+
+
+ Nombre de générateurs
+ 4
+
+ 2
+
+
+ Surface chauffée
+ 85 m²
+
+ 2
+
+
+ Année d'installation
+ 2010
+
+ 2
+
+
+ Energie utilisée
+ Electricité
+
+ 2
+
+
+ Présence d'une ventouse
+ Non
+
+ 2
+
+
+ Présence d'une veilleuse
+ Non
+
+ 2
+
+
+ Type émetteur
+ Convecteur électrique NF**
+
+ 2
+
+
+ Surface chauffée par émetteur
+ 85 m²
+
+ 2
+
+
+ Type de chauffage
+ Divisé
+
+ 2
+
+
+ Equipement d'intermittence
+ Absent
+
+ 2
+
+
+ Présence de comptage
+ Non
+
+ 2
+
+
+
+
+ 7
+
+
+ Type d’installation de chauffage
+ Installation de chauffage sans solaire
+
+ 2
+
+
+ Type générateur
+ Radiateur électrique NF**
+
+ 2
+
+
+ Nombre de générateurs
+ 4
+
+ 2
+
+
+ Surface chauffée
+ 85 m²
+
+ 2
+
+
+ Année d'installation
+ 2022
+
+ 2
+
+
+ Energie utilisée
+ Electricité
+
+ 2
+
+
+ Présence d'une ventouse
+ Non
+
+ 2
+
+
+ Présence d'une veilleuse
+ Non
+
+ 2
+
+
+ Type émetteur
+ Radiateur électrique NF**
+
+ 2
+
+
+ Surface chauffée par émetteur
+ 85 m²
+
+ 2
+
+
+ Type de chauffage
+ Divisé
+
+ 2
+
+
+ Equipement d'intermittence
+ Par pièce avec minimum de température
+
+ 2
+
+
+ Présence de comptage
+ Non
+
+ 2
+
+
+
+
+ 8
+
+
+ Type générateur
+ Chauffe-eau vertical Electrique
+
+ 2
+
+
+ Année installation
+ 2020
+
+ 2
+
+
+ Energie utilisée
+ Electricité
+
+ 2
+
+
+ Type production ECS
+ Individuel
+
+ 2
+
+
+ Isolation du réseau de distribution
+ Non
+
+ 2
+
+
+ Pièces alimentées contiguës
+ Oui
+
+ 2
+
+
+ Production en volume habitable
+ Oui
+
+ 2
+
+
+ Volume de stockage
+ 50 L
+
+ 2
+
+
+ Type de ballon
+ Chauffe-eau vertical
+
+ 2
+
+
+ Catégorie de ballon
+ B ou 2 étoiles
+
+ 2
+
+
+
+
+ 10
+
+
+ Type de ventilation
+ VMC SF Auto réglable de 2001 à 2012
+
+ 2
+
+
+ Année installation
+ 2012
+
+ 1
+
+
+ Plusieurs façades exposées
+ Non
+
+ 2
+
+
+ Menuiseries avec joints
+ Oui
+
+ 2
+
+
+
+
+ 11
+
+
+ Département
+ 31 - Haute Garonne
+
+ 2
+
+
+ Altitude
+ 146
+
+ 4
+
+
+ Type de bien
+ Immeuble collectif
+
+ 2
+
+
+ Année de construction
+ 1980
+
+ 5
+
+
+ Surface habitable du logement
+ 170
+
+ 2
+
+
+ Surface habitable de l’immeuble
+ 170
+
+ 2
+
+
+ Nombre de niveaux de l’immeuble
+ 2
+
+ 2
+
+
+ Hauteur moyenne sous plafond
+ 2.4
+
+ 2
+
+
+ Nb. de logements du bâtiment
+ 8
+
+ 2
+
+
+
+
+
+
+
+ 13
+ Faire vérifier et compléter les isolants par un professionnel
+ isolation
+
+
+ 9
+ Vérifier la température d'eau du ballon (55°C -60°C) pour éviter le risque de
+ développement de la légionelle (en dessous de 50°C) .
+
+ chauffe-eau
+
+
+ 5
+ Fermer les volets de chaque pièce pendant la nuit
+ vitrages
+
+
+ 4
+ Eteindre les lumières lorsque personne n'utilise la pièce.
+ éclairage
+
+
+ 3
+ Ne jamais placer un meuble devant un émetteur de chaleur
+ radiateur
+
+
+ 1
+ Ne jamais boucher les entrées d'air
+ ventilation
+
+
+
+ Des travaux peuvent vous permettre d'améliorer significativement l’efficacité
+ énergétique de votre logement et ainsi de faire des économies d’énergie, d’améliorer son confort, de le
+ valoriser et de le rendre plus écologique. Le pack de travaux vous permet de réaliser les travaux
+ prioritaires, et le pack d’aller vers un logement très performant.
+
+
+
+ 1
+ 147.210223565222
+ 3800
+ 11000
+
+
+ 5
+ PAC Air Air : Installation d'une pompe à chaleur air / air
+
+
+ SCOP 4.5
+
+
+ 8
+ Installer une VMC Hygroréglable type B : Installer une VMC Hygroréglable
+ type B
+
+
+
+
+
+
+
+ 2
+ 134.300435384306
+ 11065
+ 22721
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 3
+ Isolation des combles : Isolation des combles
+ Ménager impérativement une lame d'air de plus de 2 cm pour la
+ ventilation de la charpente
+
+ R = 6 m².K/W
+
+
+
+
+ 3
+ 134.300435384306
+ 14865
+ 33721
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 1
+ Isolation des murs par l'extérieur : Si un ravalement de façade est
+ prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au
+ niveau des tableaux des baies quand cela est possible.
+ Envisager prioritairement une isolation des murs par l'extérieur, elle permet de
+ limiter les ponts thermiques.
+ Mise en place d'un isolant avec une résistance de 6m²k/W
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ R = 3.7m².K/W
+
+
+ 3
+ Isolation des combles : Isolation des combles
+ Ménager impérativement une lame d'air de plus de 2 cm pour la
+ ventilation de la charpente
+
+ R = 6 m².K/W
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Isolation thermique des portes d'entrée donnant sur l'extérieur.
+ : Isolation thermique des portes d'entrée donnant sur l'extérieur.
+
+ Travaux pouvant nécessiter une autorisation d'urbanisme
+
+ Ud < 2 W/m².K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 4
+ Remplacement menuiserie et vitrage peu émissif : Remplacement des fenêtres
+ et portes- fenêtres par des menuiseries avec double-vitrage peu émissif.
+ (Pour bénéficier du crédit d'impôt pour dépenses d'équipement de l'habitation
+ principale, choisir un Uw ≤1,3 W/m².K et un facteur de transmission solaire Sw ≥ 0,3 ou un
+ Uw ≤ 1,7 W/m².K et un facteur de transmission solaire Sw ≥ 0,36.
+ Montant estimé par fenêtre
+
+ Lors du changement des fenêtres et s'il n'y a pas d'entrées
+ d'air par ailleurs, prévoir des fenêtres avec des entrées d'air intégrées pour
+ assurer le renouvellement de l'air
+
+ Uw <1,7W/m²K
+
+
+ 8
+ Installer une VMC Hygroréglable type B : Installer une VMC Hygroréglable
+ type B
+
+
+
+
+
+ 5
+ PAC Air Air : Installation d'une pompe à chaleur air / air
+
+
+ SCOP 4.5
+
+
+
+
+
+
diff --git a/test/fixtures/2574E0561248M.xml b/test/fixtures/2574E0561248M.xml
new file mode 100644
index 0000000..9c9bd02
--- /dev/null
+++ b/test/fixtures/2574E0561248M.xml
@@ -0,0 +1,2895 @@
+
+
+ 2574E0561248M
+ ACTIF
+
+
+ 25/IMO/0388
+
+
+ 2.4
+ 2025-02-17
+
+
+
+ 2025-02-19
+ 1
+
+ 26615
+ LICIEL Diagnostics v4 [Version XML:308]
+ 3cl_tribu_2024.6.1.0
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ 27A avenue Anna De Nouailles
+ 74500
+ EVIAN LES BAINS
+ 27A avenue Anna De Nouailles 74500 EVIAN LES BAINS
+ 27A avenue Anna De Nouailles 74500 EVIAN LES BAINS ODM 10874017
+ 1
+ 2025-02-19
+ 74119_0750
+
+ Avenue Anna De Noailles 74500 Évian-les-Bains
+
+ Avenue Anna De Noailles
+ 74119
+ 74500
+ Évian-les-Bains
+ street
+ 0.47081999999999996
+ 975063.21
+ 6595050.11
+
+ 25/IMO/0388
+ 0
+
+ ODM 10874017
+
+
+
+
+
+
+
+
+
+
+
+ 2
+ 6
+ 1
+ 4
+ 2.7
+ 237
+ 3
+
+
+ 3
+ 391
+ 1
+ 0
+
+
+
+ 0
+ 0
+ 1
+ 3
+
+
+
+
+ Mur 1 Nord - Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur l'extérieur
+ 2025_02_19_11_16_45_489525200796829
+
+ 1
+ 1
+ 2
+ 64
+ 64
+ 3
+ 25
+ 2
+ 20
+ 2
+ 2
+ 1
+
+ 1
+ 2.5
+ 2.5
+
+
+
+
+ Mur 2 Est sur Immeuble - Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur un local chauffé
+ 2025_02_19_11_18_23_8381495009745888
+
+ 283
+ 22
+ 3
+ 81
+ 81
+ 3
+ 25
+ 2
+ 20
+ 2
+ 2
+ 1
+
+ 0
+ 2.5
+ 2.5
+
+
+
+
+ Mur 3 Sud - Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur l'extérieur
+ 2025_02_19_11_18_22_9018093005464076
+
+ 1
+ 1
+ 1
+ 46.92
+ 46.92
+ 3
+ 25
+ 2
+ 20
+ 2
+ 2
+ 1
+
+ 1
+ 2.5
+ 2.5
+
+
+
+
+ Mur 3 Sud sur PC - Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur un hall d'entrée sans dispositif de fermeture automatique
+ 2025_02_19_11_39_30_0508690006460652
+ LNC2025_02_19_11_39_30_0508690006460652
+ 107
+ 20
+ 30
+ 2
+ 18
+ 1
+ 15.62
+ 15.62
+ 3
+ 25
+ 2
+ 20
+ 2
+ 2
+ 1
+
+ 0.75
+ 2.5
+ 2.5
+
+
+
+
+ Mur 5 Ouest - Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur l'extérieur
+ 2025_02_19_11_18_21_88532900007362056
+
+ 1
+ 1
+ 4
+ 42.93
+ 42.93
+ 3
+ 25
+ 2
+ 20
+ 2
+ 2
+ 1
+
+ 1
+ 2.5
+ 2.5
+
+
+
+
+ Mur 6 Ouest - Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur un local chauffé
+ 2025_02_19_11_23_45_2416581008881045
+
+ 283
+ 22
+ 4
+ 58.5
+ 58.5
+ 3
+ 25
+ 2
+ 20
+ 2
+ 2
+ 1
+
+ 0
+ 2.5
+ 2.5
+
+
+
+
+
+
+ Plancher 1 - Plancher inconnu non isolé donnant sur un local non chauffé non accessible
+ 2025_02_19_11_28_07_5258242008621107
+
+ 7
+ 1
+ 7
+ 60
+ 1
+ 1
+ 2
+ 2
+ 1
+ 0
+
+ 0.95
+ 2
+ 2
+ 2
+
+
+
+
+ Plancher 2 - Plancher inconnu non isolé donnant sur un hall d'entrée sans dispositif de fermeture automatique
+ 2025_02_19_11_33_45_7648068004553817
+ LNC2025_02_19_11_33_45_7648068004553817
+ 107
+ 20
+ 30
+ 2
+ 18
+ 19
+ 1
+ 1
+ 2
+ 2
+ 1
+ 0
+
+ 0.75
+ 2
+ 2
+ 2
+
+
+
+
+
+
+ Plafond - Plafond entre solives bois avec ou sans remplissage non isolé donnant sur un comble fortement ventilé
+ 2025_02_19_11_25_33_9215156009677172
+ LNC2025_02_19_11_25_33_9215156009677172
+ 124
+ 90
+ 97.2
+ 2
+ 11
+ 90
+ 4
+ 4
+ 2
+ 2
+ 1
+
+ 0.8
+ 1.2
+ 1.2
+
+
+
+
+
+
+ Porte-fenêtre 1 Nord - Portes-fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ 2025_02_19_11_43_21_3922254004183078
+ 2025_02_19_11_16_45_489525200796829
+
+ 1
+ 1
+ 16.56
+ 1
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 411
+ 5
+ 7
+ 0
+ 1.3
+ 0.39
+ 1
+ 7
+ 2
+ 0
+ 0
+ 0
+ 10
+ 126
+ 3
+ 2
+ 19
+
+
+ 1
+ 1.1
+ 1.3
+ 1.2
+ 1.2
+ 0.39
+ 1
+ 1
+
+
+
+
+
+ Porte-fenêtre 2 Sud - Portes-fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 2025_02_19_11_47_42_8163159005161511
+ 2025_02_19_11_18_22_9018093005464076
+
+ 1
+ 1
+ 4.6
+ 1
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 411
+ 5
+ 7
+ 0
+ 1.3
+ 0.39
+ 1
+ 7
+ 2
+ 0
+ 0
+ 0
+ 10
+ 126
+ 3
+ 1
+ 19
+
+
+ 1
+ 1.1
+ 1.3
+ 1.2
+ 1.2
+ 0.39
+ 1
+ 1
+
+
+
+
+
+ fenêtre 3 Sud - Portes-fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 2025_02_19_11_49_03_2269762006678058
+ 2025_02_19_11_18_22_9018093005464076
+
+ 1
+ 1
+ 6.8
+ 1
+ 37
+ 2
+ 3
+ 2
+ 20
+ 1
+ 1
+ 411
+ 5
+ 7
+ 0
+ 1.3
+ 0.39
+ 1
+ 7
+ 2
+ 0
+ 0
+ 0
+ 10
+ 126
+ 3
+ 1
+ 19
+
+
+ 1
+ 1.1
+ 1.3
+ 1.2
+ 1.2
+ 0.39
+ 1
+ 1
+
+
+
+
+
+
+
+ Porte - Porte(s) bois avec 30-60% de vitrage simple
+ 2025_02_19_11_40_39_7492414005617245
+ 2025_02_19_11_39_30_0508690006460652
+ LNC2025_02_19_11_40_39_7492414005617245
+ 2
+ 18
+ 107
+ 20
+ 30
+ 2.2
+ 3
+ 1
+ 3
+ 1
+ 5
+ 0
+ 0
+ 2
+
+ 4.5
+ 0.75
+
+
+
+
+
+
+
+ Mur 1 Nord / Porte-fenêtre 1 Nord
+ PT_2
+ 2025_02_19_11_43_21_3922254004183078
+ 2025_02_19_11_16_45_489525200796829
+ 74
+ 1
+ 34.8
+ 1
+ 5
+
+ 0.19
+
+
+
+
+ Mur 3 Sud / Porte-fenêtre 2 Sud
+ PT_3
+ 2025_02_19_11_47_42_8163159005161511
+ 2025_02_19_11_18_22_9018093005464076
+ 74
+ 1
+ 11.2
+ 1
+ 5
+
+ 0.19
+
+
+
+
+ Mur 3 Sud / fenêtre 3 Sud
+ PT_4
+ 2025_02_19_11_49_03_2269762006678058
+ 2025_02_19_11_18_22_9018093005464076
+ 74
+ 1
+ 17.6
+ 1
+ 5
+
+ 0.19
+
+
+
+
+ Mur 1 Nord / Plancher Int.
+ PT_6
+ Plancher_int
+ 2025_02_19_11_16_45_489525200796829
+ 29
+ 1
+ 30
+ 1
+ 2
+
+ 0.86
+
+
+
+
+ Mur 3 Sud / Plancher Int.
+ PT_8
+ Plancher_int
+ 2025_02_19_11_18_22_9018093005464076
+ 29
+ 1
+ 30
+ 1
+ 2
+
+ 0.86
+
+
+
+
+
+
+
+ 237
+ VMC SF Auto réglable de 1982 à 2000
+ 2025_02_19_11_12_18_8336759002623525
+
+ 1
+ 2
+ 1
+ 4
+ 4
+ 0
+
+
+ 179.883
+ 2
+ 1576
+ 36.30764
+ 132.957
+
+
+
+
+
+
+
+
+ Ballon électrique à accumulation horizontal, contenance ballon 200 L
+ 2025_02_19_11_57_59_7546336002514822
+ 1
+ 1
+ 1
+ 79
+ 1
+ 1
+ 1
+ 1
+ 1
+
+ 0.93
+ 1321.3424560475999
+ 1864.03667906715
+ 2484.05833983613
+ 3067.60051512597
+
+
+
+
+ Electrique - Ballon électrique à accumulation horizontal
+ Generateur:2025_02_19_11_57_59_7546336002514822
+
+
+ 68
+
+ 2
+ 1
+ 1
+ 5
+
+ 3
+ 1
+ 200
+
+ 1
+ 1
+ 2484.05833983613
+ 3067.60051512597
+ 0.571967
+
+
+
+
+
+
+ Combiné au système de chauffage, contenance ballon 70 L
+ 2025_02_19_12_01_20_2338101009479271
+ 1
+ 1
+ 1
+ 79
+ 1
+ 1
+ 1
+ 1
+ 1
+
+ 0.93
+ 1321.3424560475999
+ 1864.03667906715
+ 2639.30046175816
+ 3271.83035348609
+
+
+
+
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Generateur:2025_02_19_12_01_20_2338101009479271
+
+ Generateur:2025_02_19_11_56_34_05241200007768059#1
+ 56
+
+ 3
+ 2
+ 12
+ 1
+
+ 3
+ 0
+ 70
+ 1
+
+ 18000
+ 180
+ 0.922553
+ 1
+ 0.538324
+ 2639.30046175816
+ 3271.83035348609
+
+
+
+
+
+
+ Ballon électrique à accumulation vertical (autres catégorie ou inconnue), contenance ballon 300 L
+ 2025_02_19_12_02_36_8260629008812211
+ 1
+ 1
+ 1
+ 79
+ 1
+ 1
+ 1
+ 3
+ 1
+
+ 0.83
+ 1321.3424560475999
+ 1864.03667906715
+ 2655.23886270795
+ 3309.08732417729
+
+
+
+
+ Electrique - Ballon électrique à accumulation vertical (autres catégorie ou inconnue)
+ Generateur:2025_02_19_12_02_36_8260629008812211
+
+
+ 69
+
+ 2
+ 1
+ 1
+ 10
+
+ 3
+ 0
+ 300
+
+ 1
+ 1
+ 2655.23886270795
+ 3309.08732417729
+ 0.599561
+
+
+
+
+
+
+
+
+ Générateur à air chaud à combustion à condensation installé à partir de 2006 régulée (système individuel)
+ 2025_02_19_11_52_37_65637710009929979
+ 79
+ 1
+ 1
+ 1
+ 1
+ 1
+
+ 14242.3900001625
+ 17330.0708602249
+ 21793.2313076143
+ 26446.5021305705
+
+
+
+
+
+ Emetteur:2025_02_19_11_52_37_65637710009929979#1
+ 79
+ 4
+ 2
+ 14
+ 5
+ 109
+ 0
+ 1
+ 1
+ 1
+ 2
+ 4
+ 1
+
+ 0.95
+ 0.95
+ 0.8
+ 0.96
+
+
+
+
+
+
+ Gaz Naturel - Générateur à air chaud à combustion à condensation installé à partir de 2006
+ Generateur:2025_02_19_11_52_37_65637710009929979#1
+
+
+ Sans Objet
+ 52
+ 1
+ 2
+ 1
+ 73
+
+ 1
+ 1
+ 1
+ 1
+
+ 18000
+ 190.728022
+ 0.9
+ 0.83
+ 0.815655
+ 21793.2313076143
+ 26446.5021305705
+
+
+
+
+
+
+ Convecteur électrique NFC, NF** et NF*** (système individuel)
+ 2025_02_19_11_55_16_9033501001511937
+ 79
+ 1
+ 1
+ 1
+ 1
+ 1
+
+ 14242.3900001625
+ 17330.0708602249
+ 13063.9024178617
+ 15896.0929036505
+
+
+
+
+
+ Emetteur:2025_02_19_11_55_16_9033501001511937#1
+ 79
+ 1
+ 1
+ 1
+ 1
+ 102
+ 0
+ 1
+ 2
+ 1
+ 1
+ 1
+ 1
+
+ 0.9
+ 0.95
+ 1
+ 0.99
+
+
+
+
+
+
+ Electrique - Convecteur électrique NFC, NF** et NF***
+ Generateur:2025_02_19_11_55_16_9033501001511937#1
+
+ Sans Objet
+ 98
+ 1
+ 1
+ 1
+ 29
+
+ 1
+ 1
+
+ 1
+ 13063.9024178617
+ 15896.0929036505
+
+
+
+
+
+
+ Chaudière individuelle gaz à condensation installée entre 2001 et 2015 régulée. Emetteur(s): radiateur bitube sans robinet thermostatique
+ 2025_02_19_11_56_34_05241200007768059
+ 79
+ 1
+ 1
+ 1
+ 1
+ 1
+
+ 14242.3900001625
+ 17330.0708602249
+ 18544.464712549
+ 22587.0553898377
+
+
+
+
+
+ Emetteur:2025_02_19_11_56_34_05241200007768059#1
+ 79
+ 7
+ 5
+ 11
+ 34
+ 110
+ 0
+ 1
+ 1
+ 1
+ 2
+ 4
+ 1
+
+ 0.96
+ 0.95
+ 0.88
+ 0.9
+
+
+
+
+
+
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Generateur:2025_02_19_11_56_34_05241200007768059#1
+
+ Generateur:2025_02_19_12_01_20_2338101009479271
+ Sans Objet
+ 96
+ 3
+ 2
+ 0
+ 12
+
+ 1
+ 1
+ 1
+ 1
+
+ 18000
+ 180
+ 38
+ 80
+ 0.922553
+ 0.982553
+ 0.939285
+ 18544.464712549
+ 22587.0553898377
+
+
+
+
+
+
+
+ 132.95700000000002
+ 36.30764056414791
+ 169.26464056414792
+ 413.9125
+ 142.5
+ 86.4
+ 33.552
+ 7.425
+ 63.684
+ 916.7381405641479
+
+
+ 90.035712
+ 0
+ 0
+ 3560.4115185600003
+ 6617.155875
+ 0.18019851110854293
+ 0.15857242359283319
+ 113.16483609876155
+ 165.373248606993
+ 503.39783490983444
+ 0
+ 0
+ 6.1635
+ 345.156
+ 486.9165
+ 42727.170000487589
+ 51990.212580674663
+ 3964.0273681428
+ 5592.11003720145
+ 0
+ 0
+
+
+ 53401.598438025
+ 64929.650424058695
+ 7778.5976643022395
+ 9648.51819278935
+ 440.76312
+ 95.582261778868542
+ 211.88629288526664
+ 420.39786570439543
+ 3.5823062141734927
+ 5.0536105521376067
+ 0
+ 1575.77508
+ 2095.3375136974373
+ 0
+ 0
+ 63716.296736024684
+ 268
+
+
+ 70384.671581245231
+ 70384.671581245231
+ 14459.684027609543
+ 14459.684027609543
+ 1013.755176
+ 219.83920209139762
+ 219.83920209139762
+ 966.91509112010942
+ 8.2393042925990319
+ 8.2393042925990319
+ 0
+ 3624.2826839999993
+ 4819.2762815041051
+ 0
+ 0
+ 90677.38706635889
+ 382
+ F
+
+
+ 10188.705287588142
+ 10188.705287588142
+ 933.17552298446731
+ 933.17552298446731
+ 30.412655280000003
+ 6.1172647538475866
+ 6.1172647538475866
+ 26.905463405081306
+ 0.22926759770710353
+ 0.22926759770710353
+ 0
+ 100.84960511999999
+ 134.10160087663598
+ 0
+ 0
+ 11286.395066729248
+ 47
+ D
+
+
+ 7141.5731121045246
+ 7141.5731121045246
+ 1386.1918070892291
+ 1386.1918070892291
+ 94.532095198045724
+ 20.49988091046394
+ 20.49988091046394
+ 90.164283848937146
+ 0.76831045226016037
+ 0.76831045226016037
+ 0
+ 337.96230472564969
+ 449.39477993731094
+ 0
+ 0
+ 9071.6917943291119
+
+
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+
+
+
+ 2
+ 40337.69602016329
+ 2639.3004617581591
+ 42976.996481921451
+ 9156.6569965770668
+ 599.1212048191021
+ 9755.77820139617
+ 4339.7096825524259
+ 283.9477436522813
+ 4623.657426204707
+
+
+ 1
+ 13063.902417861715
+ 5139.29720254408
+ 20739.300254103233
+ 1032.0482910110754
+ 334.0543181653652
+ 1530.6168653330767
+ 2801.8634295520988
+ 1102.2440634369477
+ 4448.034368124403
+
+
+
+
+ 2.0284
+ 4
+ 4
+ 4
+ 1
+
+
+
+
+
+
+
+ Apt 1
+ 1
+ 4
+ 79
+
+
+ Apt 2
+ 2
+ 4
+ 79
+
+
+ Apt 3
+ 3
+ 4
+ 79
+
+
+
+
+
+
+ VMC SF Auto réglable de 1982 à 2000
+ 8
+
+
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur l'extérieur
+ 1
+
+
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur un local chauffé
+ 1
+
+
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur l'extérieur
+ 1
+
+
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur un hall d'entrée sans dispositif de fermeture automatique
+ 1
+
+
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur l'extérieur
+ 1
+
+
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu d'épaisseur 25 cm non isolé donnant sur un local chauffé
+ 1
+
+
+ Plafond entre solives bois avec ou sans remplissage non isolé donnant sur un comble fortement ventilé
+ 3
+
+
+ Plancher inconnu non isolé donnant sur un local non chauffé non accessible
+ 2
+
+
+ Plancher inconnu non isolé donnant sur un hall d'entrée sans dispositif de fermeture automatique
+ 2
+
+
+ Porte(s) bois avec 30-60% de vitrage simple
+ 4
+
+
+ Portes-fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ 4
+
+
+ Portes-fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Portes-fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Générateur à air chaud à combustion à condensation installé à partir de 2006 régulée (système individuel)
+ 5
+
+
+ Générateur à air chaud à combustion à condensation installé à partir de 2006 régulée (système individuel)
+ 9
+
+
+ Convecteur électrique NFC, NF** et NF*** (système individuel)
+ 5
+
+
+ Convecteur électrique NFC, NF** et NF*** (système individuel)
+ 9
+
+
+ Chaudière individuelle gaz à condensation installée entre 2001 et 2015 régulée. Emetteur(s): radiateur bitube sans robinet thermostatique
+ 5
+
+
+ Chaudière individuelle gaz à condensation installée entre 2001 et 2015 régulée. Emetteur(s): radiateur bitube sans robinet thermostatique
+ 9
+
+
+ Ballon électrique à accumulation horizontal, contenance ballon 200 L
+ 6
+
+
+ Combiné au système de chauffage, contenance ballon 70 L
+ 6
+
+
+ Ballon électrique à accumulation vertical (autres catégorie ou inconnue), contenance ballon 300 L
+ 6
+
+
+
+
+ 11
+
+
+ Département: 74 Haute Savoie
+ 74 Haute Savoie
+
+ 2
+
+
+ Altitude: 391 m
+ 391 m
+
+ 4
+
+
+ Type de bien: Immeuble Complet
+ Immeuble Complet
+
+ 2
+
+
+ Année de construction: 1948 - 1974
+ 1948 - 1974
+
+ 5
+
+
+ Surface de référence de l'immeuble: 237 m²
+ 237 m²
+
+ 2
+
+
+ Nombre de niveaux du logement: -
+ -
+
+ 2
+
+
+ Nombre de niveaux de l'immeuble: 4
+ 4
+
+ 2
+
+
+ Hauteur moyenne sous plafond: 2,7 m
+ 2,7 m
+
+ 2
+
+
+ Nb. de logements du bâtiment: 3
+ 3
+
+ 2
+
+
+ Liste des logements visités: Apt__1, Apt__2, Apt__3
+ Apt__1, Apt__2, Apt__3
+
+ 2
+
+
+ Type de répartition du chauffage: Système de chauffage individuel géré de manière non homogène
+ Système de chauffage individuel géré de manière non homogène
+
+ 2
+
+
+ Type de répartition de l'eau chaude sanitaire: Système d'ecs individuel géré de manière non homogène
+ Système d'ecs individuel géré de manière non homogène
+
+ 2
+
+
+ Menuiseries, systèmes de ventilation et chauffage similaires sur tous les appartements: Non
+ Non
+
+ 2
+
+
+ Coef IFC: 1
+ 1
+
+ 3
+
+
+
+
+ 1
+
+
+ Surface du mur: 64 m²
+ 64 m²
+
+ 2
+
+
+ Type d'adjacence: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+
+ 2
+
+
+ Epaisseur mur: 25 cm
+ 25 cm
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface du mur: 81 m²
+ 81 m²
+
+ 2
+
+
+ Type d'adjacence: un local chauffé
+ un local chauffé
+
+ 2
+
+
+ Matériau mur: Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+
+ 2
+
+
+ Epaisseur mur: 25 cm
+ 25 cm
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface du mur: 46,92 m²
+ 46,92 m²
+
+ 2
+
+
+ Type d'adjacence: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+
+ 2
+
+
+ Epaisseur mur: 25 cm
+ 25 cm
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface du mur: 15,62 m²
+ 15,62 m²
+
+ 2
+
+
+ Type d'adjacence: un hall d'entrée sans dispositif de fermeture automatique
+ un hall d'entrée sans dispositif de fermeture automatique
+
+ 2
+
+
+ Surface Aiu: 20 m²
+ 20 m²
+
+ 2
+
+
+ Etat isolation des parois Aiu: non isolé
+ non isolé
+
+ 2
+
+
+ Surface Aue: 30 m²
+ 30 m²
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Matériau mur: Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+
+ 2
+
+
+ Epaisseur mur: 25 cm
+ 25 cm
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface du mur: 42,93 m²
+ 42,93 m²
+
+ 2
+
+
+ Type d'adjacence: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+
+ 2
+
+
+ Epaisseur mur: 25 cm
+ 25 cm
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface du mur: 58,5 m²
+ 58,5 m²
+
+ 2
+
+
+ Type d'adjacence: un local chauffé
+ un local chauffé
+
+ 2
+
+
+ Matériau mur: Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+ Mur en pierre de taille et moellons constitué d'un seul matériau ou inconnu
+
+ 2
+
+
+ Epaisseur mur: 25 cm
+ 25 cm
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 2
+
+
+ Surface de plancher bas: 60 m²
+ 60 m²
+
+ 2
+
+
+ Type d'adjacence: un local non chauffé non accessible
+ un local non chauffé non accessible
+
+ 2
+
+
+ Type de pb: Plancher inconnu
+ Plancher inconnu
+
+ 2
+
+
+ Isolation : oui / non / inconnue: non
+ non
+
+ 2
+
+
+
+
+ 2
+
+
+ Surface de plancher bas: 19 m²
+ 19 m²
+
+ 2
+
+
+ Type d'adjacence: un hall d'entrée sans dispositif de fermeture automatique
+ un hall d'entrée sans dispositif de fermeture automatique
+
+ 2
+
+
+ Surface Aiu: 20 m²
+ 20 m²
+
+ 2
+
+
+ Etat isolation des parois Aiu: non isolé
+ non isolé
+
+ 2
+
+
+ Surface Aue: 30 m²
+ 30 m²
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Type de pb: Plancher inconnu
+ Plancher inconnu
+
+ 2
+
+
+ Isolation : oui / non / inconnue: non
+ non
+
+ 2
+
+
+
+
+ 3
+
+
+ Surface de plancher haut: 90 m²
+ 90 m²
+
+ 2
+
+
+ Type d'adjacence: un comble fortement ventilé
+ un comble fortement ventilé
+
+ 2
+
+
+ Surface Aiu: 90 m²
+ 90 m²
+
+ 2
+
+
+ Etat isolation des parois Aiu: non isolé
+ non isolé
+
+ 2
+
+
+ Surface Aue: 97,2 m²
+ 97,2 m²
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Type de ph: Plafond entre solives bois avec ou sans remplissage
+ Plafond entre solives bois avec ou sans remplissage
+
+ 2
+
+
+ Isolation: non
+ non
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 6,8 m²
+ 6,8 m²
+
+ 2
+
+
+ Constaté dans les logements: Apt__1 (Qté 2), Apt__2 (Qté 1), Apt__3 (Qté 1)
+ Apt__1 (Qté 2), Apt__2 (Qté 1), Apt__3 (Qté 1)
+
+ 2
+
+
+ Placement: Mur 3 Sud
+ Mur 3 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Portes-fenêtres battantes
+ Portes-fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 20 mm
+ 20 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Argon / Krypton
+ Argon / Krypton
+
+ 2
+
+
+ Longueur Pont Thermique: 17,6 m
+ 17,6 m
+
+ 2
+
+
+ Positionnement de la menuiserie: en tunnel
+ en tunnel
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 10 cm
+ Lp: 10 cm
+
+ 2
+
+
+ Type volets: Vénitiens extérieurs tout métal
+ Vénitiens extérieurs tout métal
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Absence de masque lointain
+ Absence de masque lointain
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 16,56 m²
+ 16,56 m²
+
+ 2
+
+
+ Constaté dans les logements: Apt__1 (Qté 2), Apt__2 (Qté 2), Apt__3 (Qté 2)
+ Apt__1 (Qté 2), Apt__2 (Qté 2), Apt__3 (Qté 2)
+
+ 2
+
+
+ Placement: Mur 1 Nord
+ Mur 1 Nord
+
+ 2
+
+
+ Orientation des baies: Nord
+ Nord
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Portes-fenêtres battantes
+ Portes-fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 20 mm
+ 20 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Argon / Krypton
+ Argon / Krypton
+
+ 2
+
+
+ Longueur Pont Thermique: 34,8 m
+ 34,8 m
+
+ 2
+
+
+ Positionnement de la menuiserie: en tunnel
+ en tunnel
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 10 cm
+ Lp: 10 cm
+
+ 2
+
+
+ Type volets: Vénitiens extérieurs tout métal
+ Vénitiens extérieurs tout métal
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Absence de masque lointain
+ Absence de masque lointain
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 4,6 m²
+ 4,6 m²
+
+ 2
+
+
+ Constaté dans les logements: Apt__2 (Qté 1), Apt__3 (Qté 1)
+ Apt__2 (Qté 1), Apt__3 (Qté 1)
+
+ 2
+
+
+ Placement: Mur 3 Sud
+ Mur 3 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Portes-fenêtres battantes
+ Portes-fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 20 mm
+ 20 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Argon / Krypton
+ Argon / Krypton
+
+ 2
+
+
+ Longueur Pont Thermique: 11,2 m
+ 11,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: en tunnel
+ en tunnel
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 10 cm
+ Lp: 10 cm
+
+ 2
+
+
+ Type volets: Vénitiens extérieurs tout métal
+ Vénitiens extérieurs tout métal
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Absence de masque lointain
+ Absence de masque lointain
+
+ 2
+
+
+
+
+ 5
+
+
+ Surface de porte: 2,2 m²
+ 2,2 m²
+
+ 2
+
+
+ Placement: Mur 3 Sud sur PC
+ Mur 3 Sud sur PC
+
+ 2
+
+
+ Type d'adjacence: un hall d'entrée sans dispositif de fermeture automatique
+ un hall d'entrée sans dispositif de fermeture automatique
+
+ 2
+
+
+ Surface Aiu: 20 m²
+ 20 m²
+
+ 2
+
+
+ Etat isolation des parois Aiu: non isolé
+ non isolé
+
+ 2
+
+
+ Surface Aue: 30 m²
+ 30 m²
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Nature de la menuiserie: Porte simple en bois
+ Porte simple en bois
+
+ 2
+
+
+ Type de porte: Porte avec 30-60% de vitrage simple
+ Porte avec 30-60% de vitrage simple
+
+ 2
+
+
+ Présence de joints d'étanchéité: non
+ non
+
+ 2
+
+
+ Longueur Pont Thermique: 5,4 m
+ 5,4 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique: Mur 1 Nord / Porte-fenêtre 1 Nord
+ Mur 1 Nord / Porte-fenêtre 1 Nord
+
+ 2
+
+
+ Type isolation: non isolé
+ non isolé
+
+ 2
+
+
+ Longueur du PT: 34,8 m
+ 34,8 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp: Lp: 10 cm
+ Lp: 10 cm
+
+ 2
+
+
+ Position menuiseries: en tunnel
+ en tunnel
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique: Mur 3 Sud / Porte-fenêtre 2 Sud
+ Mur 3 Sud / Porte-fenêtre 2 Sud
+
+ 2
+
+
+ Type isolation: non isolé
+ non isolé
+
+ 2
+
+
+ Longueur du PT: 11,2 m
+ 11,2 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp: Lp: 10 cm
+ Lp: 10 cm
+
+ 2
+
+
+ Position menuiseries: en tunnel
+ en tunnel
+
+ 2
+
+
+
+
+ 6
+
+
+ Type de pont thermique: Mur 3 Sud / fenêtre 3 Sud
+ Mur 3 Sud / fenêtre 3 Sud
+
+ 2
+
+
+ Type isolation: non isolé
+ non isolé
+
+ 2
+
+
+ Longueur du PT: 17,6 m
+ 17,6 m
+
+ 2
+
+
+ Largeur du dormant menuiserie Lp: Lp: 10 cm
+ Lp: 10 cm
+
+ 2
+
+
+ Position menuiseries: en tunnel
+ en tunnel
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 1 Nord / Plancher Int.
+ Mur 1 Nord / Plancher Int.
+
+ 2
+
+
+ Type isolation: non isolé / non isolé
+ non isolé / non isolé
+
+ 2
+
+
+ Longueur du PT: 30 m
+ 30 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 3 Sud / Plancher Int.
+ Mur 3 Sud / Plancher Int.
+
+ 2
+
+
+ Type isolation: non isolé / non isolé
+ non isolé / non isolé
+
+ 2
+
+
+ Longueur du PT: 30 m
+ 30 m
+
+ 2
+
+
+
+
+ 10
+
+
+ Type de ventilation: VMC SF Auto réglable de 1982 à 2000
+ VMC SF Auto réglable de 1982 à 2000
+
+ 2
+
+
+ Année installation: 2000 (estimée en fonction de la marque et du modèle)
+ 2000 (estimée en fonction de la marque et du modèle)
+
+ 2
+
+
+ Energie utilisée: Electrique
+ Electrique
+
+ 2
+
+
+ Façades exposées: plusieurs
+ plusieurs
+
+ 2
+
+
+ Logement Traversant: oui
+ oui
+
+ 2
+
+
+ Commentaires: Une VMC est presente dans les combles, mais elle ne semble pas fonctionner dans les logements. Présence d'humidité dans les logements.
+ Une VMC est presente dans les combles, mais elle ne semble pas fonctionner dans les logements. Présence d'humidité dans les logements.
+
+ 2
+
+
+
+
+ 7
+
+
+ Constaté dans les logements: Apt__3
+ Apt__3
+
+ 2
+
+
+ Type d'installation de chauffage: Installation de chauffage simple
+ Installation de chauffage simple
+
+ 2
+
+
+ Surface chauffée: 79 m²
+ 79 m²
+
+ 2
+
+
+ Type générateur: Gaz Naturel - Générateur à air chaud à combustion à condensation installé à partir de 2006
+ Gaz Naturel - Générateur à air chaud à combustion à condensation installé à partir de 2006
+
+ 2
+
+
+ Année installation générateur: 2006
+ 2006
+
+ 2
+
+
+ Energie utilisée: Gaz Naturel
+ Gaz Naturel
+
+ 2
+
+
+ Cper (présence d'une ventouse): oui
+ oui
+
+ 2
+
+
+ Présence d'une veilleuse: non
+ non
+
+ 2
+
+
+ Présence d'une régulation/Ajust,T° Fonctionnement: oui
+ oui
+
+ 2
+
+
+ Présence ventilateur / dispositif circulation air dans circuit combustion: non
+ non
+
+ 2
+
+
+ Type émetteur: Générateur à air chaud à combustion à condensation installé à partir de 2006
+ Générateur à air chaud à combustion à condensation installé à partir de 2006
+
+ 2
+
+
+ Température de distribution: supérieur à 65°C
+ supérieur à 65°C
+
+ 2
+
+
+ Année installation émetteur: Inconnue
+ Inconnue
+
+ 2
+
+
+ Type de chauffage: central
+ central
+
+ 2
+
+
+ Equipement intermittence: Sans système d'intermittence
+ Sans système d'intermittence
+
+ 2
+
+
+
+
+ 7
+
+
+ Constaté dans les logements: Apt__2
+ Apt__2
+
+ 2
+
+
+ Type d'installation de chauffage: Installation de chauffage simple
+ Installation de chauffage simple
+
+ 2
+
+
+ Surface chauffée: 79 m²
+ 79 m²
+
+ 2
+
+
+ Type générateur: Electrique - Convecteur électrique NFC, NF** et NF***
+ Electrique - Convecteur électrique NFC, NF** et NF***
+
+ 2
+
+
+ Année installation générateur: 1948 - 1974
+ 1948 - 1974
+
+ 1
+
+
+ Energie utilisée: Electrique
+ Electrique
+
+ 2
+
+
+ Type émetteur: Convecteur électrique NFC, NF** et NF***
+ Convecteur électrique NFC, NF** et NF***
+
+ 2
+
+
+ Année installation émetteur: Inconnue
+ Inconnue
+
+ 2
+
+
+ Type de chauffage: divisé
+ divisé
+
+ 2
+
+
+ Equipement intermittence: Sans système d'intermittence
+ Sans système d'intermittence
+
+ 2
+
+
+
+
+ 7
+
+
+ Constaté dans les logements: Apt__1
+ Apt__1
+
+ 2
+
+
+ Type d'installation de chauffage: Installation de chauffage simple
+ Installation de chauffage simple
+
+ 2
+
+
+ Surface chauffée: 79 m²
+ 79 m²
+
+ 2
+
+
+ Nombre de niveaux desservis: 1
+ 1
+
+ 2
+
+
+ Type générateur: Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+
+ 2
+
+
+ Année installation générateur: 2001
+ 2001
+
+ 2
+
+
+ Energie utilisée: Gaz Naturel
+ Gaz Naturel
+
+ 2
+
+
+ Cper (présence d'une ventouse): oui
+ oui
+
+ 2
+
+
+ Présence d'une veilleuse: non
+ non
+
+ 2
+
+
+ Chaudière murale: oui
+ oui
+
+ 2
+
+
+ Présence d'une régulation/Ajust,T° Fonctionnement: oui
+ oui
+
+ 2
+
+
+ Présence ventilateur / dispositif circulation air dans circuit combustion: non
+ non
+
+ 2
+
+
+ Type émetteur: Radiateur bitube sans robinet thermostatique
+ Radiateur bitube sans robinet thermostatique
+
+ 2
+
+
+ Température de distribution: supérieur à 65°C
+ supérieur à 65°C
+
+ 2
+
+
+ Année installation émetteur: Inconnue
+ Inconnue
+
+ 2
+
+
+ Type de chauffage: central
+ central
+
+ 2
+
+
+ Equipement intermittence: Sans système d'intermittence
+ Sans système d'intermittence
+
+ 2
+
+
+
+
+ 8
+
+
+ Constaté dans les logements: Apt__2
+ Apt__2
+
+ 2
+
+
+ Nombre de niveaux desservis: 1
+ 1
+
+ 2
+
+
+ Type générateur: Electrique - Ballon électrique à accumulation horizontal
+ Electrique - Ballon électrique à accumulation horizontal
+
+ 2
+
+
+ Année installation générateur: 2001
+ 2001
+
+ 2
+
+
+ Energie utilisée: Electrique
+ Electrique
+
+ 2
+
+
+ Chaudière murale: non
+ non
+
+ 2
+
+
+ Type de distribution: production en volume habitable alimentant des pièces contiguës
+ production en volume habitable alimentant des pièces contiguës
+
+ 2
+
+
+ Type de production: accumulation
+ accumulation
+
+ 2
+
+
+ Volume de stockage: 200 L
+ 200 L
+
+ 2
+
+
+
+
+ 8
+
+
+ Constaté dans les logements: Apt__3
+ Apt__3
+
+ 2
+
+
+ Nombre de niveaux desservis: 1
+ 1
+
+ 2
+
+
+ Type générateur: Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+
+ 2
+
+
+ Année installation générateur: 2001
+ 2001
+
+ 2
+
+
+ Energie utilisée: Gaz Naturel
+ Gaz Naturel
+
+ 2
+
+
+ Type production ECS: Chauffage et ECS
+ Chauffage et ECS
+
+ 2
+
+
+ Présence d'une veilleuse: non
+ non
+
+ 2
+
+
+ Chaudière murale: oui
+ oui
+
+ 2
+
+
+ Présence d'une régulation/Ajust,T° Fonctionnement: oui
+ oui
+
+ 2
+
+
+ Présence ventilateur / dispositif circulation air dans circuit combustion: non
+ non
+
+ 2
+
+
+ Type de distribution: production en volume habitable alimentant des pièces contiguës
+ production en volume habitable alimentant des pièces contiguës
+
+ 2
+
+
+ Type de production: accumulation
+ accumulation
+
+ 2
+
+
+ Volume de stockage: 70 L
+ 70 L
+
+ 2
+
+
+
+
+ 8
+
+
+ Constaté dans les logements: Apt__1
+ Apt__1
+
+ 2
+
+
+ Nombre de niveaux desservis: 1
+ 1
+
+ 2
+
+
+ Type générateur: Electrique - Ballon électrique à accumulation vertical (autres catégorie ou inconnue)
+ Electrique - Ballon électrique à accumulation vertical (autres catégorie ou inconnue)
+
+ 2
+
+
+ Année installation générateur: 2001
+ 2001
+
+ 2
+
+
+ Energie utilisée: Electrique
+ Electrique
+
+ 2
+
+
+ Chaudière murale: oui
+ oui
+
+ 2
+
+
+ Type de distribution: production hors volume habitable
+ production hors volume habitable
+
+ 2
+
+
+ Type de production: accumulation
+ accumulation
+
+ 2
+
+
+ Volume de stockage: 300 L
+ 300 L
+
+ 2
+
+
+
+
+
+
+ Descriptifs des équipements collectifs - Syndic
+ 7
+
+
+ Plans du logement
+ 1
+
+
+ Notices techniques des équipements
+ 10
+
+
+
+
+ Vérifier la température d'eau du ballon (55°C-60°C) pour éviter le risque de développement de la légionnelle (en dessous de 50°C).
+ 9
+ Chauffe-eau
+
+
+ Eteindre les lumières lorsque personne n'utilise la pièce.
+ 4
+ Eclairage
+
+
+ Faire vérifier les isolants et les compléter tous les 20 ans.
+ 13
+ Isolation
+
+
+ Laisser les robinets thermostatiques en position ouverte en fin de saison de chauffe.
+ 3
+ Radiateur
+
+
+ Ne jamais placer un meuble devant un émetteur de chaleur.
+ 3
+ Radiateur
+
+
+ Purger les radiateurs s'il y a de l'air.
+ 3
+ Radiateur
+
+
+ Nettoyage et réglage de l'installation tous les 3 ans par un professionnel.
+ 1
+ Ventilation
+
+
+ Nettoyer régulièrement les bouches.
+ 1
+ Ventilation
+
+
+ Veiller à ouvrir les fenêtres de chaque pièce très régulièrement
+ 1
+ Ventilation
+
+
+
+
+
+ 1
+ 178
+ 24
+ 100
+ 150
+
+
+ Installer une VMC hygroréglable type B et reprise de l'etanchéité à l'air de l'enveloppe
+ 8
+
+
+
+
+ Isolation des murs par l'extérieur.
+Si un ravalement de façade est prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au niveau des tableaux des baies quand cela est possible.
+ 1
+
+ R > 3,7 m².K/W
+
+
+ Isolation des plafonds par l'extérieur.
+ 3
+
+ R > 6 m².K/W
+
+
+ Remplacer les portes par des menuiseries plus performantes.
+ 4
+
+ Ud = 1,3 W/m².K
+
+
+ Mettre à jour le système d'intermittence / régulation (programmateur, robinets thermostatique, isolation réseau)
+Remplacer le système de chauffage par une pompe à chaleur air/air non réversible (la c
+ 5
+
+ SCOP = 4
+
+
+ Système actualisé en même temps que le chauffage
+ 6
+
+
+
+
+
+
+ 3
+ 39
+ 1
+ 100
+ 150
+
+
+ Isolation des murs par l'extérieur.
+Si un ravalement de façade est prévu, effectuer une isolation par l'extérieur avec des retours d'isolants au niveau des tableaux des baies quand cela est possible.
+ 1
+
+ R > 3,7 m².K/W
+
+
+ Isolation des planchers en sous face.
+ 2
+
+ R > 3 m².K/W
+
+
+ Remplacer le système de chauffage par une pompe à chaleur air/air non réversible (la climatisation n'est pas considérée, en cas de mise en place votre étiquette énergie augmentera sensiblement).
+Remp
+ 5
+
+ SCOP = 4
+
+
+ Remplacer le système actuel par un appareil de type pompe à chaleur.
+Mettre en place un système Solaire
+Système actualisé en même temps que le chauffage
+ 6
+
+ COP = 3VbSimpleCrCOP = 4
+
+
+
+
+
+
+
\ No newline at end of file
diff --git a/test/fixtures/2592E0472851H.xml b/test/fixtures/2592E0472851H.xml
new file mode 100644
index 0000000..81ca772
--- /dev/null
+++ b/test/fixtures/2592E0472851H.xml
@@ -0,0 +1,4674 @@
+
+
+ 2592E0472851H
+ ACTIF
+
+
+ DPESAB08350120240311
+
+
+ 2.4
+ 2025-02-11
+
+
+
+ 2025-02-11
+ 1
+
+ 26615
+ LICIEL Diagnostics v4 [Version XML:308]
+ 3cl_tribu_2024.6.1.0
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ 30 AVENUE DE VERDUN 1916, 28 AVENUE DE VERDUN 1916
+ 92250
+ LA GARENNE COLOMBES
+ 30 AVENUE DE VERDUN 1916, 28 AVENUE DE VERDUN 1916 92250 LA GARENNE COLOMBES
+ 30 AVENUE DE VERDUN 1916, 28 AVENUE DE VERDUN 1916 92250 LA GARENNE COLOMBES
+ 1
+ 2025-02-11
+ 92035_9615_00030
+
+ 30 Avenue de Verdun 1916 92250 La Garenne-Colombes
+ 30
+ Avenue de Verdun 1916
+ 92035
+ 92250
+ La Garenne-Colombes
+ housenumber
+ 0.63523000000000007
+ 643767.09
+ 6867474.6
+
+ DPESAB08350120240311
+ 0
+
+
+
+
+
+
+
+
+
+
+
+
+
+ 2013
+ 9
+ 9
+ 2
+ 7
+ 2.5
+ 4668
+ 70
+
+
+ 1
+ 40
+ 1
+ 0
+
+
+
+ 1
+ 0
+ 0
+ 3
+
+
+
+
+ Mur 1 Nord - Mur en béton banché d'épaisseur ≤ 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 2025_02_11_19_49_29_8034256004663855
+
+ 1
+ 1
+ 2
+ 392
+ 392
+ 81
+ 20
+ 13
+ 20
+ 2
+ 3
+ 9
+ 44
+ 7
+
+ 1
+ 0.22999999999999998
+ 2.5
+
+
+
+
+ Mur 2 Sud - Mur en béton banché d'épaisseur ≤ 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 2025_02_11_19_49_49_5142727004065136
+
+ 1
+ 1
+ 1
+ 573
+ 573
+ 81
+ 20
+ 13
+ 20
+ 2
+ 3
+ 9
+ 44
+ 7
+
+ 1
+ 0.22999999999999998
+ 2.5
+
+
+
+
+ Mur 3 Est - Mur en béton banché d'épaisseur ≤ 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 2025_02_11_19_49_49_219820100629575
+
+ 1
+ 1
+ 3
+ 464
+ 464
+ 81
+ 20
+ 13
+ 20
+ 2
+ 3
+ 9
+ 44
+ 7
+
+ 1
+ 0.22999999999999998
+ 2.5
+
+
+
+
+ Mur 4 Ouest - Mur en béton banché d'épaisseur ≤ 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 2025_02_11_19_49_48_9665570007749274
+
+ 1
+ 1
+ 4
+ 339
+ 339
+ 81
+ 20
+ 13
+ 20
+ 2
+ 3
+ 9
+ 44
+ 7
+
+ 1
+ 0.22999999999999998
+ 2.5
+
+
+
+
+
+
+ Plancher 1 - Dalle béton donnant sur un sous-sol non chauffé avec isolation intrinsèque ou en sous-face (réalisée entre 2013 et 2021)
+ 2025_02_11_19_52_32_3827182009456019
+
+ 6
+ 6
+ 500
+ 9
+ 9
+ 2
+ 4
+ 9
+ 44
+ 7
+ 1
+ 150
+ 500
+ 0.20333333
+
+ 1
+ 0.22999999999999998
+ 0.20333333
+ 2
+
+
+
+
+ Plancher 2 - Dalle béton donnant sur un hall d'entrée sans dispositif de fermeture automatique avec isolation intrinsèque ou en sous-face (réalisée entre 2013 et 2021)
+ 2025_02_11_19_53_07_7304759001971719
+ LNC2025_02_11_19_53_07_7304759001971719
+ 110
+ 100
+ 60
+ 2
+ 18
+ 100
+ 9
+ 9
+ 2
+ 4
+ 9
+ 44
+ 7
+ 0
+
+ 0.5
+ 0.22999999999999998
+ 0.22999999999999998
+ 2
+
+
+
+
+ Plancher 3 - Dalle béton donnant sur l'extérieur avec isolation intrinsèque ou en sous-face (réalisée entre 2013 et 2021)
+ 2025_02_11_19_53_33_2688421005207092
+
+ 1
+ 1
+ 50
+ 9
+ 9
+ 2
+ 4
+ 9
+ 44
+ 7
+ 0
+
+ 1
+ 0.22999999999999998
+ 0.22999999999999998
+ 2
+
+
+
+
+
+
+ Plafond 1 - Plafond structure inconnu (sous combles perdus) donnant sur un comble faiblement ventilé avec isolation intérieure (réalisée entre 2013 et 2021)
+ 2025_02_11_19_51_38_8954459002209767
+ LNC2025_02_11_19_51_38_8954459002209767
+ 108
+ 600
+ 600
+ 2
+ 12
+ 600
+ 1
+ 1
+ 2
+ 3
+ 9
+ 44
+ 7
+
+ 0.7
+ 0.13999999999999999
+ 2.5
+
+
+
+
+ Plafond 2 - Dalle béton donnant sur l'extérieur (terrasse) avec isolation extérieure (réalisée entre 2013 et 2021)
+ 2025_02_11_19_52_14_8035926004787994
+
+ 1
+ 1
+ 50
+ 8
+ 8
+ 2
+ 4
+ 9
+ 92
+ 7
+
+ 1
+ 0.13999999999999999
+ 2.5
+
+
+
+
+
+
+ Fenêtre 1 Sud - Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 2025_02_11_20_17_12_486533600835247
+ 2025_02_11_19_49_49_5142727004065136
+
+ 1
+ 1
+ 39.1
+ 23
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 1
+ 19
+ 5
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Fenêtre 2 Sud - Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 2025_02_11_20_17_50_6338563001249925
+ 2025_02_11_19_49_49_5142727004065136
+
+ 1
+ 1
+ 4.76
+ 2
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 1
+ 19
+ 5
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Fenêtre 3 Sud - Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 2025_02_11_20_18_32_469176200009082437
+ 2025_02_11_19_49_49_5142727004065136
+
+ 1
+ 1
+ 16.32
+ 12
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 1
+ 19
+ 5
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Fenêtre 4 Sud - Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 2025_02_11_20_18_59_1550728001981214
+ 2025_02_11_19_49_49_5142727004065136
+
+ 1
+ 1
+ 67.2
+ 32
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 1
+ 19
+ 5
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F1 Nord [1] - Fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_32_4803410007015261
+ 2025_02_11_19_49_29_8034256004663855
+
+ 1
+ 1
+ 68
+ 40
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 2
+ 19
+ 1
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F3 Nord [2] - Fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_33_1018829007820452
+ 2025_02_11_19_49_29_8034256004663855
+
+ 1
+ 1
+ 8.16
+ 6
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 2
+ 19
+ 1
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto PF1 Nord [3] - Fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_33_6583891006856294
+ 2025_02_11_19_49_29_8034256004663855
+
+ 1
+ 1
+ 31.5
+ 15
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 2
+ 19
+ 1
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F1 Est [4] - Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_34_2262283005031056
+ 2025_02_11_19_49_49_219820100629575
+
+ 1
+ 1
+ 47.6
+ 28
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 3
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F2 Est [5] - Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_34_8006726002773768
+ 2025_02_11_19_49_49_219820100629575
+
+ 1
+ 1
+ 2.38
+ 1
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 3
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F3 Est [6] - Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_35_3720129001222726
+ 2025_02_11_19_49_49_219820100629575
+
+ 1
+ 1
+ 21.76
+ 16
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 3
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto PF1 Est [7] - Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_35_9437456004834593
+ 2025_02_11_19_49_49_219820100629575
+
+ 1
+ 1
+ 29.4
+ 14
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 3
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto PF2 Est [8] - Portes-fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_36_5064202008687408
+ 2025_02_11_19_49_49_219820100629575
+
+ 1
+ 1
+ 35.28
+ 12
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 414
+ 5
+ 7
+ 0
+ 1.5
+ 0.39
+ 5
+ 186
+ 6
+ 0
+ 0
+ 0
+ 5
+ 126
+ 2
+ 3
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.5
+ 1.3
+ 1.3
+ 0.39
+ 1
+ 1
+
+
+
+
+
+ Auto F1 Ouest [9] - Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_37_1337286006501827
+ 2025_02_11_19_49_48_9665570007749274
+
+ 1
+ 1
+ 17
+ 10
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 4
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F2 Ouest [10] - Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_37_76108740006078565
+ 2025_02_11_19_49_48_9665570007749274
+
+ 1
+ 1
+ 2.38
+ 1
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 4
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto F3 Ouest [11] - Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_38_3245026001865664
+ 2025_02_11_19_49_48_9665570007749274
+
+ 1
+ 1
+ 13.6
+ 10
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 4
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto PF1 Ouest [12] - Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_38_9013293005670824
+ 2025_02_11_19_49_48_9665570007749274
+
+ 1
+ 1
+ 10.5
+ 5
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 334
+ 5
+ 4
+ 0
+ 1.6
+ 0.38
+ 5
+ 187
+ 6
+ 0
+ 0
+ 0
+ 5
+ 111
+ 2
+ 4
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.6
+ 1.4
+ 1.4
+ 0.38
+ 1
+ 1
+
+
+
+
+
+ Auto PF2 Ouest [13] - Portes-fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ AutoAddEchantillon2025_02_11_20_20_39_48147070003239173
+ 2025_02_11_19_49_48_9665570007749274
+
+ 1
+ 1
+ 17.64
+ 6
+ 17
+ 2
+ 3
+ 1
+ 16
+ 1
+ 1
+ 414
+ 5
+ 7
+ 0
+ 1.5
+ 0.39
+ 5
+ 186
+ 6
+ 0
+ 0
+ 0
+ 5
+ 126
+ 2
+ 4
+ 19
+ 9
+
+
+ 1
+ 1.4
+ 1.5
+ 1.3
+ 1.3
+ 0.39
+ 1
+ 1
+
+
+
+
+
+
+
+
+
+ Mur 1 Nord / Plancher Int.
+ PT_18
+ Plancher_int
+ 2025_02_11_19_49_29_8034256004663855
+ 30
+ 1
+ 134.4
+ 1
+ 2
+
+ 0.92
+
+
+
+
+ Mur 1 Nord / Refend
+ PT_19
+ Refend
+ 2025_02_11_19_49_29_8034256004663855
+ 65
+ 1
+ 71.590909
+ 1
+ 4
+
+ 0.82
+
+
+
+
+ Mur 2 Sud / Plancher Int.
+ PT_20
+ Plancher_int
+ 2025_02_11_19_49_49_5142727004065136
+ 30
+ 1
+ 196.44
+ 1
+ 2
+
+ 0.92
+
+
+
+
+ Mur 2 Sud / Refend
+ PT_21
+ Refend
+ 2025_02_11_19_49_49_5142727004065136
+ 65
+ 1
+ 100.227273
+ 1
+ 4
+
+ 0.82
+
+
+
+
+ Mur 3 Est / Plancher Int.
+ PT_22
+ Plancher_int
+ 2025_02_11_19_49_49_219820100629575
+ 30
+ 1
+ 159.06
+ 1
+ 2
+
+ 0.92
+
+
+
+
+ Mur 3 Est / Refend
+ PT_23
+ Refend
+ 2025_02_11_19_49_49_219820100629575
+ 65
+ 1
+ 85.909091
+ 1
+ 4
+
+ 0.82
+
+
+
+
+ Mur 4 Ouest / Plancher Int.
+ PT_24
+ Plancher_int
+ 2025_02_11_19_49_48_9665570007749274
+ 30
+ 1
+ 116.22
+ 1
+ 2
+
+ 0.92
+
+
+
+
+ Mur 4 Ouest / Refend
+ PT_25
+ Refend
+ 2025_02_11_19_49_48_9665570007749274
+ 65
+ 1
+ 57.272727
+ 1
+ 4
+
+ 0.82
+
+
+
+
+
+
+
+ 4668
+ VMC SF Hygro B après 2012 (collective)
+ 2025_02_11_19_49_19_2595781004663174
+
+ 1
+ 4
+ 1
+ 15
+ 15
+ 0
+
+
+ 1272.03
+ 1
+ 11143
+ 121.93304
+ 1729.9608
+
+
+
+
+
+
+
+
+ Combiné au système de chauffage
+ 2025_02_11_20_22_25_5128808005549183
+ 1
+ 2
+ 1
+ 4668
+ 1
+ 1
+ 7
+ 6
+ 2
+ 1
+
+ 0.55
+ 88221.108774288
+ 124454.778449442
+ 176895.626519219
+ 247610.989359094
+
+
+
+
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Generateur:2025_02_11_20_22_25_5128808005549183
+
+ Generateur:2025_02_11_20_21_20_4297293009216646#1
+ 56
+
+ 3
+ 2
+ 12
+ 1
+
+ 1
+ 0
+ 1
+ 0
+ 0
+
+ 145000
+ 1450
+ 0.931614
+ 1
+ 0.906761
+ 176895.626519219
+ 247610.989359094
+
+
+
+
+
+
+
+
+ Chaudière collective gaz à condensation installée entre 2001 et 2015 régulée, avec équipement d'intermittence central collectif, réseau isolé. Emetteur(s): radiateur bitube avec robinet thermostatique
+ 2025_02_11_20_21_20_4297293009216646
+ 4668
+ 1
+ 7
+ 1
+ 2
+ 1
+
+ 94462.0514782559
+ 123516.928452823
+ 130783.067183669
+ 171098.708412763
+
+
+
+
+
+ Emetteur:2025_02_11_20_21_20_4297293009216646#1
+ 4668
+ 7
+ 9
+ 12
+ 37
+ 160
+ 1
+ 6
+ 2
+ 3
+ 2
+ 3
+ 1
+
+ 1.01
+ 0.95
+ 0.9
+ 0.95
+
+
+
+
+
+
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Generateur:2025_02_11_20_21_20_4297293009216646#1
+
+ Generateur:2025_02_11_20_22_25_5128808005549183
+ Sans Objet
+ 96
+ 3
+ 2
+ 0
+ 12
+
+ 0
+ 1
+ 1
+ 1
+
+ 145000
+ 1450
+ 32
+ 60
+ 0.931614
+ 0.991614
+ 0.962497
+ 130783.067183669
+ 171098.708412763
+
+
+
+
+
+
+
+ 1729.9608000000003
+ 121.93303867454613
+ 1851.8938386745465
+ 406.64
+ 124.666665
+ 65.8
+ 600.31999999999994
+ 0
+ 815.93040000000008
+ 3865.2509036745469
+
+
+ 1453.955372
+ 0
+ 0
+ 55040.303101560006
+ 150366.69120000003
+ 0.57127323271013419
+ 0.52751417423079217
+ 5935.7288958018262
+ 8578.9099686370228
+ 0
+ 0
+ 0
+ 134.764
+ 7546.7840000000006
+ 10646.356000000002
+ 94462.051478255875
+ 123516.92845282253
+ 88221.108774288
+ 124454.778449442
+ 0
+ 0
+
+
+ 130783.06718366884
+ 171098.70841276317
+ 176895.62651921931
+ 247610.98935909357
+ 8822.52
+ 164.16853084496884
+ 378.83243408711559
+ 4657.1019615780942
+ 153.3222028353143
+ 216.29382185696127
+ 355.05504708384865
+ 11142.982800000003
+ 16472.630542342231
+ 0
+ 0
+ 332973.84424523031
+ 71
+
+
+ 130783.06718366884
+ 130783.06718366884
+ 176895.62651921931
+ 176895.62651921931
+ 20291.796
+ 377.58762094342831
+ 377.58762094342831
+ 10711.334511629615
+ 352.64106652122285
+ 352.64106652122285
+ 816.62660829285187
+ 25628.860440000008
+ 37887.050247387124
+ 0
+ 0
+ 365857.53995027527
+ 78
+ C
+
+
+ 29687.75625069283
+ 29687.75625069283
+ 40155.307219862785
+ 40155.307219862785
+ 608.75388000000009
+ 10.506785974078007
+ 10.506785974078007
+ 298.05452554099804
+ 9.8126209814601157
+ 9.8126209814601157
+ 22.723523013366314
+ 713.15089920000025
+ 1054.2483547099027
+ 0
+ 0
+ 71506.06570526553
+ 15
+ C
+
+
+ 12251.240017955026
+ 12251.240017955026
+ 16570.882036050822
+ 16570.882036050822
+ 3063.2671692000004
+ 33.61270672075603
+ 33.61270672075603
+ 953.5189332418845
+ 31.391973913383083
+ 31.391973913383083
+ 72.695790757996974
+ 2281.471430139849
+ 3372.6908347738695
+ 0
+ 0
+ 35258.080057979714
+
+
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+ 0
+
+
+
+ 2
+ 130783.06718366884
+ 176895.62651921931
+ 307678.69370288815
+ 29687.75625069283
+ 40155.307219862785
+ 69843.063470555615
+ 12251.240017955026
+ 16570.882036050822
+ 28822.122054005849
+
+
+ 1
+ 0
+ 0
+ 25295.150542342231
+ 0
+ 0
+ 1663.002234709903
+ 0
+ 0
+ 6435.95800397387
+
+
+
+
+ 0.5752
+ 1
+ 1
+ 1
+ 1
+
+
+
+
+
+
+
+ DPESAB083516629220240311
+ 1
+ 4
+ 75
+
+
+ DPESAB083516629520240311
+ 2
+ 4
+ 75.4
+
+
+ DPESAB083516629920240311
+ 2
+ 4
+ 75.4
+
+
+ DPESAB083516630920240311
+ 2
+ 4
+ 75.4
+
+
+ DPESAB083516632220240311
+ 3
+ 5
+ 97.1
+
+
+ DPESAB083516634920240311
+ 2
+ 2
+ 45.5
+
+
+ DPESAB083516636020240311
+ 3
+ 3
+ 65.1
+
+
+
+
+
+
+ VMC SF Hygro B après 2012 (collective)
+ 8
+
+
+ Mur en béton banché d'épaisseur 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 1
+
+
+ Mur en béton banché d'épaisseur 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 1
+
+
+ Mur en béton banché d'épaisseur 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 1
+
+
+ Mur en béton banché d'épaisseur 20 cm avec isolation intérieure (réalisée entre 2013 et 2021) donnant sur l'extérieur
+ 1
+
+
+ Plafond structure inconnu (sous combles perdus) donnant sur un comble faiblement ventilé avec isolation intérieure (réalisée entre 2013 et 2021)
+ 3
+
+
+ Dalle béton donnant sur l'extérieur (terrasse) avec isolation extérieure (réalisée entre 2013 et 2021)
+ 3
+
+
+ Dalle béton donnant sur un sous-sol non chauffé avec isolation intrinsèque ou en sous-face (réalisée entre 2013 et 2021)
+ 2
+
+
+ Dalle béton donnant sur un hall d'entrée sans dispositif de fermeture automatique avec isolation intrinsèque ou en sous-face (réalisée entre 2013 et 2021)
+ 2
+
+
+ Dalle béton donnant sur l'extérieur avec isolation intrinsèque ou en sous-face (réalisée entre 2013 et 2021)
+ 2
+
+
+ Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Portes-fenêtres battantes pvc, orientées Sud, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Nord, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ 4
+
+
+ Portes-fenêtres battantes pvc, orientées Est, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ 4
+
+
+ Fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ 4
+
+
+ Portes-fenêtres battantes pvc, orientées Ouest, double vitrage à isolation renforcée
+ 4
+
+
+ Chaudière collective gaz à condensation installée entre 2001 et 2015 régulée, avec équipement d'intermittence central collectif, réseau isolé. Emetteur(s): radiateur bitube avec robinet thermostatique
+ 5
+
+
+ Chaudière collective gaz à condensation installée entre 2001 et 2015 régulée, avec équipement d'intermittence central collectif, réseau isolé. Emetteur(s): radiateur bitube avec robinet thermostatique
+ 9
+
+
+ Combiné au système de chauffage
+ 6
+
+
+
+
+ 11
+
+
+ Département: 92 Hauts de Seine
+ 92 Hauts de Seine
+
+ 2
+
+
+ Altitude: 40 m
+ 40 m
+
+ 4
+
+
+ Type de bien: Immeuble Complet
+ Immeuble Complet
+
+ 2
+
+
+ Année de construction: 2013
+ 2013
+
+ 5
+
+
+ Surface de référence de l'immeuble: 4668 m²
+ 4668 m²
+
+ 2
+
+
+ Nombre de niveaux du logement: -
+ -
+
+ 2
+
+
+ Nombre de niveaux de l'immeuble: 7
+ 7
+
+ 2
+
+
+ Hauteur moyenne sous plafond: 2,5 m
+ 2,5 m
+
+ 2
+
+
+ Nb. de logements du bâtiment: 70
+ 70
+
+ 2
+
+
+ Liste des logements visités: DPESAB08351662922024, DPESAB08351662952024, DPESAB08351662992024, DPESAB08351663092024, DPESAB08351663222024, DPESAB08351663492024, DPESAB08351663602024
+ DPESAB08351662922024, DPESAB08351662952024, DPESAB08351662992024, DPESAB08351663092024, DPESAB08351663222024, DPESAB08351663492024, DPESAB08351663602024
+
+ 2
+
+
+ Type de répartition du chauffage: Système de chauffage collectif sans individualisation des frais
+ Système de chauffage collectif sans individualisation des frais
+
+ 2
+
+
+ Type de répartition de l'eau chaude sanitaire: Système d'ecs collectif
+ Système d'ecs collectif
+
+ 2
+
+
+ Menuiseries, systèmes de ventilation et chauffage similaires sur tous les appartements: Oui
+ Oui
+
+ 2
+
+
+
+
+ 1
+
+
+ Surface du mur: 392 m²
+ 392 m²
+
+ 2
+
+
+ Type de local adjacent: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en béton banché
+ Mur en béton banché
+
+ 2
+
+
+ Epaisseur mur: 20 cm
+ 20 cm
+
+ 2
+
+
+ Isolation: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 1
+
+
+ Surface du mur: 573 m²
+ 573 m²
+
+ 2
+
+
+ Type de local adjacent: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en béton banché
+ Mur en béton banché
+
+ 2
+
+
+ Epaisseur mur: 20 cm
+ 20 cm
+
+ 2
+
+
+ Isolation: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 1
+
+
+ Surface du mur: 464 m²
+ 464 m²
+
+ 2
+
+
+ Type de local adjacent: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en béton banché
+ Mur en béton banché
+
+ 2
+
+
+ Epaisseur mur: 20 cm
+ 20 cm
+
+ 2
+
+
+ Isolation: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 1
+
+
+ Surface du mur: 339 m²
+ 339 m²
+
+ 2
+
+
+ Type de local adjacent: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Matériau mur: Mur en béton banché
+ Mur en béton banché
+
+ 2
+
+
+ Epaisseur mur: 20 cm
+ 20 cm
+
+ 2
+
+
+ Isolation: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 2
+
+
+ Surface de plancher bas: 500 m²
+ 500 m²
+
+ 2
+
+
+ Type de local adjacent: un sous-sol non chauffé
+ un sous-sol non chauffé
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Périmètre plancher bâtiment déperditif: 150 m
+ 150 m
+
+ 2
+
+
+ Surface plancher bâtiment déperditif: 500 m²
+ 500 m²
+
+ 2
+
+
+ Type de pb: Dalle béton
+ Dalle béton
+
+ 2
+
+
+ Isolation : oui / non / inconnue: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 2
+
+
+ Surface de plancher bas: 100 m²
+ 100 m²
+
+ 2
+
+
+ Type de local adjacent: un hall d'entrée sans dispositif de fermeture automatique
+ un hall d'entrée sans dispositif de fermeture automatique
+
+ 2
+
+
+ Surface Aiu: 100 m²
+ 100 m²
+
+ 2
+
+
+ Etat isolation des parois Aiu: non isolé
+ non isolé
+
+ 2
+
+
+ Surface Aue: 60 m²
+ 60 m²
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Type de pb: Dalle béton
+ Dalle béton
+
+ 2
+
+
+ Isolation : oui / non / inconnue: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 2
+
+
+ Surface de plancher bas: 50 m²
+ 50 m²
+
+ 2
+
+
+ Type de local adjacent: l'extérieur
+ l'extérieur
+
+ 2
+
+
+ Type de pb: Dalle béton
+ Dalle béton
+
+ 2
+
+
+ Isolation : oui / non / inconnue: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 3
+
+
+ Surface de plancher haut: 600 m²
+ 600 m²
+
+ 2
+
+
+ Type de local adjacent: un comble faiblement ventilé
+ un comble faiblement ventilé
+
+ 2
+
+
+ Surface Aiu: 600 m²
+ 600 m²
+
+ 2
+
+
+ Etat isolation des parois Aiu: non isolé
+ non isolé
+
+ 2
+
+
+ Surface Aue: 600 m²
+ 600 m²
+
+ 2
+
+
+ Etat isolation des parois Aue: non isolé
+ non isolé
+
+ 2
+
+
+ Type de ph: Plafond structure inconnu (en combles)
+ Plafond structure inconnu (en combles)
+
+ 2
+
+
+ Isolation: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 3
+
+
+ Surface de plancher haut: 50 m²
+ 50 m²
+
+ 2
+
+
+ Type de local adjacent: l'extérieur (terrasse)
+ l'extérieur (terrasse)
+
+ 2
+
+
+ Type de ph: Dalle béton
+ Dalle béton
+
+ 2
+
+
+ Isolation: oui
+ oui
+
+ 2
+
+
+ Année isolation: 2013 - 2021
+ 2013 - 2021
+
+ 3
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,7 m²
+ 1,7 m²
+
+ 2
+
+
+ Placement: Mur 3 Est
+ Mur 3 Est
+
+ 2
+
+
+ Orientation des baies: Est
+ Est
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,4 m
+ 5,4 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,7 m²
+ 1,7 m²
+
+ 2
+
+
+ Placement: Mur 1 Nord
+ Mur 1 Nord
+
+ 2
+
+
+ Orientation des baies: Nord
+ Nord
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,4 m
+ 5,4 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,7 m²
+ 1,7 m²
+
+ 2
+
+
+ Placement: Mur 4 Ouest
+ Mur 4 Ouest
+
+ 2
+
+
+ Orientation des baies: Ouest
+ Ouest
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,4 m
+ 5,4 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,38 m²
+ 2,38 m²
+
+ 2
+
+
+ Placement: Mur 3 Est
+ Mur 3 Est
+
+ 2
+
+
+ Orientation des baies: Est
+ Est
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 6,2 m
+ 6,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,38 m²
+ 2,38 m²
+
+ 2
+
+
+ Placement: Mur 4 Ouest
+ Mur 4 Ouest
+
+ 2
+
+
+ Orientation des baies: Ouest
+ Ouest
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 6,2 m
+ 6,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,36 m²
+ 1,36 m²
+
+ 2
+
+
+ Placement: Mur 3 Est
+ Mur 3 Est
+
+ 2
+
+
+ Orientation des baies: Est
+ Est
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5 m
+ 5 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,36 m²
+ 1,36 m²
+
+ 2
+
+
+ Placement: Mur 1 Nord
+ Mur 1 Nord
+
+ 2
+
+
+ Orientation des baies: Nord
+ Nord
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5 m
+ 5 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,36 m²
+ 1,36 m²
+
+ 2
+
+
+ Placement: Mur 4 Ouest
+ Mur 4 Ouest
+
+ 2
+
+
+ Orientation des baies: Ouest
+ Ouest
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5 m
+ 5 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,1 m²
+ 2,1 m²
+
+ 2
+
+
+ Placement: Mur 3 Est
+ Mur 3 Est
+
+ 2
+
+
+ Orientation des baies: Est
+ Est
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,2 m
+ 5,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,1 m²
+ 2,1 m²
+
+ 2
+
+
+ Placement: Mur 1 Nord
+ Mur 1 Nord
+
+ 2
+
+
+ Orientation des baies: Nord
+ Nord
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,2 m
+ 5,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,1 m²
+ 2,1 m²
+
+ 2
+
+
+ Placement: Mur 4 Ouest
+ Mur 4 Ouest
+
+ 2
+
+
+ Orientation des baies: Ouest
+ Ouest
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,2 m
+ 5,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,94 m²
+ 2,94 m²
+
+ 2
+
+
+ Placement: Mur 3 Est
+ Mur 3 Est
+
+ 2
+
+
+ Orientation des baies: Est
+ Est
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Portes-fenêtres battantes
+ Portes-fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,6 m
+ 5,6 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,94 m²
+ 2,94 m²
+
+ 2
+
+
+ Placement: Mur 4 Ouest
+ Mur 4 Ouest
+
+ 2
+
+
+ Orientation des baies: Ouest
+ Ouest
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Portes-fenêtres battantes
+ Portes-fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,6 m
+ 5,6 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,7 m²
+ 1,7 m²
+
+ 2
+
+
+ Placement: Mur 2 Sud
+ Mur 2 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,4 m
+ 5,4 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,38 m²
+ 2,38 m²
+
+ 2
+
+
+ Placement: Mur 2 Sud
+ Mur 2 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 6,2 m
+ 6,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 1,36 m²
+ 1,36 m²
+
+ 2
+
+
+ Placement: Mur 2 Sud
+ Mur 2 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5 m
+ 5 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,1 m²
+ 2,1 m²
+
+ 2
+
+
+ Placement: Mur 2 Sud
+ Mur 2 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Fenêtres battantes
+ Fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,2 m
+ 5,2 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 4
+
+
+ Surface de baies: 2,94 m²
+ 2,94 m²
+
+ 2
+
+
+ Placement: Mur 2 Sud
+ Mur 2 Sud
+
+ 2
+
+
+ Orientation des baies: Sud
+ Sud
+
+ 2
+
+
+ Inclinaison vitrage: vertical
+ vertical
+
+ 2
+
+
+ Type ouverture: Portes-fenêtres battantes
+ Portes-fenêtres battantes
+
+ 2
+
+
+ Type menuiserie: PVC
+ PVC
+
+ 2
+
+
+ Type de vitrage: double vitrage
+ double vitrage
+
+ 2
+
+
+ Epaisseur lame air: 16 mm
+ 16 mm
+
+ 2
+
+
+ Présence couche peu émissive: oui
+ oui
+
+ 2
+
+
+ Gaz de remplissage: Air
+ Air
+
+ 2
+
+
+ Longueur Pont Thermique: 5,6 m
+ 5,6 m
+
+ 2
+
+
+ Positionnement de la menuiserie: au nu intérieur
+ au nu intérieur
+
+ 2
+
+
+ Largeur du dormant menuiserie: Lp: 5 cm
+ Lp: 5 cm
+
+ 2
+
+
+ Type volets: Volets roulants PVC (tablier > 12mm)
+ Volets roulants PVC (tablier > 12mm)
+
+ 2
+
+
+ Type de masques proches: Absence de masque proche
+ Absence de masque proche
+
+ 2
+
+
+ Type de masques lointains: Masque homogène
+ Masque homogène
+
+ 2
+
+
+ Hauteur a (°): 0 - 15°
+ 0 - 15°
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 1 Nord / Plancher Int.
+ Mur 1 Nord / Plancher Int.
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 134,4 m
+ 134,4 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 1 Nord / Refend
+ Mur 1 Nord / Refend
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 71,6 m
+ 71,6 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 2 Sud / Plancher Int.
+ Mur 2 Sud / Plancher Int.
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 196,4 m
+ 196,4 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 2 Sud / Refend
+ Mur 2 Sud / Refend
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 100,2 m
+ 100,2 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 3 Est / Plancher Int.
+ Mur 3 Est / Plancher Int.
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 159,1 m
+ 159,1 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 3 Est / Refend
+ Mur 3 Est / Refend
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 85,9 m
+ 85,9 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 4 Ouest / Plancher Int.
+ Mur 4 Ouest / Plancher Int.
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 116,2 m
+ 116,2 m
+
+ 2
+
+
+
+
+ 6
+
+
+ Type PT: Mur 4 Ouest / Refend
+ Mur 4 Ouest / Refend
+
+ 2
+
+
+ Type isolation: ITI / non isolé
+ ITI / non isolé
+
+ 2
+
+
+ Longueur du PT: 57,3 m
+ 57,3 m
+
+ 2
+
+
+
+
+ 10
+
+
+ Type de ventilation: VMC SF Hygro B après 2012
+ VMC SF Hygro B après 2012
+
+ 2
+
+
+ Année installation: 2013
+ 2013
+
+ 1
+
+
+ Energie utilisée: Electrique
+ Electrique
+
+ 2
+
+
+ Façades exposées: plusieurs
+ plusieurs
+
+ 2
+
+
+ Logement Traversant: oui
+ oui
+
+ 2
+
+
+
+
+ 7
+
+
+ Constaté dans les logements: DPESAB08351662922024, DPESAB08351662952024, DPESAB08351662992024, DPESAB08351663092024, DPESAB08351663222024, DPESAB08351663492024, DPESAB08351663602024
+ DPESAB08351662922024, DPESAB08351662952024, DPESAB08351662992024, DPESAB08351663092024, DPESAB08351663222024, DPESAB08351663492024, DPESAB08351663602024
+
+ 2
+
+
+ Type d'installation de chauffage: Installation de chauffage simple
+ Installation de chauffage simple
+
+ 2
+
+
+ Surface chauffée: 4 668 m²
+ 4 668 m²
+
+ 2
+
+
+ Nombre de niveaux desservis: 7
+ 7
+
+ 2
+
+
+ Type générateur: Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+
+ 2
+
+
+ Année installation générateur: 2013 (estimée en fonction de la marque et du modèle)
+ 2013 (estimée en fonction de la marque et du modèle)
+
+ 2
+
+
+ Energie utilisée: Gaz Naturel
+ Gaz Naturel
+
+ 2
+
+
+ Cper (présence d'une ventouse): non
+ non
+
+ 2
+
+
+ Présence d'une veilleuse: non
+ non
+
+ 2
+
+
+ Chaudière murale: non
+ non
+
+ 2
+
+
+ Présence d'une régulation/Ajust,T° Fonctionnement: oui
+ oui
+
+ 2
+
+
+ Présence ventilateur / dispositif circulation air dans circuit combustion: non
+ non
+
+ 2
+
+
+ Type émetteur: Radiateur bitube avec robinet thermostatique
+ Radiateur bitube avec robinet thermostatique
+
+ 2
+
+
+ Température de distribution: inférieure à 65°C
+ inférieure à 65°C
+
+ 2
+
+
+ Année installation émetteur: Inconnue
+ Inconnue
+
+ 2
+
+
+ Type de chauffage: central
+ central
+
+ 2
+
+
+ Equipement d'intermittence: Avec intermittence centrale collectif
+ Avec intermittence centrale collectif
+
+ 2
+
+
+ Présence comptage: 0
+ 0
+
+ 2
+
+
+
+
+ 8
+
+
+ Constaté dans les logements: DPESAB08351662922024, DPESAB08351662952024, DPESAB08351662992024, DPESAB08351663092024, DPESAB08351663222024, DPESAB08351663492024, DPESAB08351663602024
+ DPESAB08351662922024, DPESAB08351662952024, DPESAB08351662992024, DPESAB08351663092024, DPESAB08351663222024, DPESAB08351663492024, DPESAB08351663602024
+
+ 2
+
+
+ Surface considérée: 4 668 m²
+ 4 668 m²
+
+ 2
+
+
+ Nombre de niveaux desservis: 7
+ 7
+
+ 2
+
+
+ Type générateur: Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+ Gaz Naturel - Chaudière gaz à condensation installée entre 2001 et 2015
+
+ 2
+
+
+ Année installation générateur: 2013 (estimée en fonction de la marque et du modèle)
+ 2013 (estimée en fonction de la marque et du modèle)
+
+ 2
+
+
+ Energie utilisée: Gaz Naturel
+ Gaz Naturel
+
+ 2
+
+
+ Type production ECS: Chauffage et ECS
+ Chauffage et ECS
+
+ 2
+
+
+ Présence d'une veilleuse: non
+ non
+
+ 2
+
+
+ Chaudière murale: non
+ non
+
+ 2
+
+
+ Présence d'une régulation/Ajust,T° Fonctionnement: oui
+ oui
+
+ 2
+
+
+ Présence ventilateur / dispositif circulation air dans circuit combustion: non
+ non
+
+ 2
+
+
+ Type de distribution: Réseau collectif isolé bouclé sans traçage, majorité des logements avec pièces alimentées contiguës
+ Réseau collectif isolé bouclé sans traçage, majorité des logements avec pièces alimentées contiguës
+
+ 2
+
+
+ Bouclage pour ECS: oui
+ oui
+
+ 2
+
+
+ Type de production: instantanée
+ instantanée
+
+ 2
+
+
+
+
+
+
+ Plans du logement
+ 1
+
+
+ Photographies des travaux
+ 16
+
+
+ Notices techniques des équipements
+ 10
+
+
+
+
+ Eteindre les lumières lorsque personne n'utilise la pièce.
+ 4
+ Eclairage
+
+
+ Faire vérifier les isolants et les compléter tous les 20 ans.
+ 13
+ Isolation
+
+
+ Laisser les robinets thermostatiques en position ouverte en fin de saison de chauffe.
+ 3
+ Radiateur
+
+
+ Ne jamais placer un meuble devant un émetteur de chaleur.
+ 3
+ Radiateur
+
+
+ Purger les radiateurs s'il y a de l'air.
+ 3
+ Radiateur
+
+
+ Nettoyage et réglage de l'installation tous les 3 ans par un professionnel.
+ 1
+ Ventilation
+
+
+ Nettoyer régulièrement les bouches.
+ 1
+ Ventilation
+
+
+ Veiller à ouvrir les fenêtres de chaque pièce très régulièrement
+ 1
+ Ventilation
+
+
+
+
+
+ 3
+ 44
+ 1
+ 100
+ 150
+
+
+ Remplacer le système de chauffage par une pompe à chaleur air/eau double service chauffage et ECS.
+ 5
+
+ SCOP = 4
+
+
+ Système actualisé en même temps que le chauffage
+Mettre en place un système Solaire
+ 6
+
+ COP = 4
+
+
+
+
+
+
+
\ No newline at end of file
diff --git a/test/open3cl-sorties-apport-besoin.spec.js b/test/open3cl-sorties-apport-besoin.spec.js
index 1d1b131..7f8e5b5 100644
--- a/test/open3cl-sorties-apport-besoin.spec.js
+++ b/test/open3cl-sorties-apport-besoin.spec.js
@@ -3,6 +3,7 @@ import corpus from './corpus.json';
import { getAdemeFileJson, getResultFile, saveResultFile } from './test-helpers.js';
import { describe, expect, test, beforeAll, vi } from 'vitest';
import { PRECISION, PRECISION_PERCENT } from './constant.js';
+import { expect_or } from './utils.js';
describe('Test Open3CL engine compliance on corpus', () => {
/**
@@ -50,16 +51,6 @@ describe('Test Open3CL engine compliance on corpus', () => {
});
});
- function expect_or(...tests) {
- if (!tests || !Array.isArray(tests)) return;
- try {
- tests.shift()?.();
- } catch (e) {
- if (tests.length) expect_or(...tests);
- else throw e;
- }
- }
-
describe.each(['besoin_ecs', 'besoin_ecs_depensier', 'besoin_ch', 'besoin_ch_depensier'])(
'check "%s" value',
(attr) => {
diff --git a/test/open3cl-sorties-dpe-immeuble.spec.js b/test/open3cl-sorties-dpe-immeuble.spec.js
index 5e69077..e59793b 100644
--- a/test/open3cl-sorties-dpe-immeuble.spec.js
+++ b/test/open3cl-sorties-dpe-immeuble.spec.js
@@ -1,6 +1,7 @@
import { describe, expect, test } from 'vitest';
import { getAdemeFileJson } from './test-helpers.js';
import { calcul_3cl } from '../src/index.js';
+import { expect_or } from './utils.js';
describe('DPE immeuble unit tests', () => {
test.each([
@@ -62,4 +63,22 @@ describe('DPE immeuble unit tests', () => {
);
}
);
+
+ test.each([{ code: '2574E0561248M' }, { code: '2431E1275871H' }, { code: '2592E0472851H' }])(
+ 'perte distribution ecs recup dpe immeuble: $code',
+ ({ code }) => {
+ /** @type {FullDpe} **/
+ let input = getAdemeFileJson(code);
+
+ /** @type {FullDpe} **/
+ let output = calcul_3cl(structuredClone(input));
+
+ const inputEcsRecup = input.logement.sortie.apport_et_besoin.pertes_distribution_ecs_recup;
+ const outputEcsRecup = output.logement.sortie.apport_et_besoin.pertes_distribution_ecs_recup;
+ expect_or(
+ () => expect(inputEcsRecup).toBeCloseTo(outputEcsRecup),
+ () => expect(inputEcsRecup).toBeCloseTo(outputEcsRecup / 1000)
+ );
+ }
+ );
});
diff --git a/test/utils.js b/test/utils.js
new file mode 100644
index 0000000..30d196a
--- /dev/null
+++ b/test/utils.js
@@ -0,0 +1,9 @@
+export function expect_or(...tests) {
+ if (!tests || !Array.isArray(tests)) return;
+ try {
+ tests.shift()?.();
+ } catch (e) {
+ if (tests.length) expect_or(...tests);
+ else throw e;
+ }
+}