<Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0208:000F:0200</MetaDataItem>
<MetaDataItem name="ProductPic">images/hank/hkzw-fld01.png</MetaDataItem>
<MetaDataItem id="000F" name="ZWProductPage" type="0200">https://products.z-wavealliance.org/products/2641/</MetaDataItem>
<MetaDataItem name="Description">Flood Sensor is capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, Flood Sensor can work with your z-wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless.
The features list:
1) Z-Wave Plus certified for wide compatibility (500 serials product).
2) Security 0 and security 2 framework implemented with AES-128 encryption.
3) Contains an extension water detecting probe.
4) Temperature measurement.
5) Vibration sensor.
6) The battery life is up to 1 year.
7) Low battery alert
</MetaDataItem>
<MetaDataItem name="ResetDescription">1)Power on the device,
2) Press and hold the Z button for more than 20 seconds,
3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.
4) The reset feature works only when the device has been included into a Z-Wave network.
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
</MetaDataItem>
<MetaDataItem name="WakeupDescription">Press and hold the Z button for more than 5 seconds and release.</MetaDataItem>
<MetaDataItem name="Name">Flood Sensor</MetaDataItem>
<MetaDataItem name="ExclusionDescription">1) Open the cover.
2) Place the device within the direct range of your Z-Wave controller.
3) Set the main controller remove mode (see the controller’s manual).
4) Triple click the Z-button quickly, the LED indicator should blink fast.
5) Wait for the removing process to end.
6) Successful adding will be confirmed by the Z-Wave controller’s message.
</MetaDataItem>
<MetaDataItem id="000F" name="Identifier" type="0200">HKZW-FLD01</MetaDataItem>
<MetaDataItem name="InclusionDescription">1) Open the cover.
2) Place the device within the direct range of your Z-Wave controller.
3) Set the main controller in add mode (see the controller’s manual).
4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast.
5) Wait for the adding process to end.
6) Successful adding will be confirmed by the Z-Wave controller’s message.
</MetaDataItem>
<MetaDataItem id="000F" name="FrequencyName" type="0200">CEPT (Europe)</MetaDataItem>
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/2641/Flood Sensor Specification Engineering.pdf</MetaDataItem>
<ChangeLog>
<Entry author="Justin Hammond - Justin@dynam.ac" date="02 Jun 2019" revision="2">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2641/xml</Entry>
</ChangeLog>
</MetaData>
<!--
Hank HKZW-FLD01 Flood Sensor
https://products.z-wavealliance.org/products/2641
-->
<!-- Configuration -->
<CommandClass id="112">
<Value genre="config" index="14" instance="1" label="Enable/Disable BASIC SET command" max="1" min="0" size="1" type="list" value="0">
<Help>The Flood sensor can send BASIC SET command to nodes associated with group 2.</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="15" instance="1" label="Value of the BASIC SET" max="1" min="0" size="1" type="list" value="0">
<Help>The Flood sensor can reverse its value of BASIC SET when flooding is triggered.</Help>
<Item label="Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled." value="0"/>
<Item label="Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled." value="1"/>
</Value>
<Value genre="config" index="17" instance="1" label="Enable/Disable flooding alarm" max="1" min="0" size="1" type="list" value="1">
<Help></Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="18" instance="1" label="Enable/Disable shock alarm" max="1" min="0" size="1" type="list" value="0">
<Help></Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="19" instance="1" label="Enable/Disable high temperature alarm" max="1" min="0" size="1" type="list" value="0">
<Help></Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="20" instance="1" label="Set the high temperature alarm trigger value" max="2570" min="-670" size="2" type="short">
<Help>US: -670 - 2570 (-67 - 257 F)
Other: -550 - 1250 (-55 - 125 C)</Help>
</Value>
<Value genre="config" index="21" instance="1" label="Enable/Disable low temperature alarm" max="1" min="0" size="1" type="list" value="0">
<Help></Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="22" instance="1" label="Set the low temperature alarm trigger value" max="2570" min="-670" size="2" type="short" value="0">
<Help>US: -670 - 2570 (-67 - 257 F)
Other: -550 - 1250 (-55 - 125 C)</Help>
</Value>
<Value genre="config" index="24" instance="1" label="Enable/Disable blinking LED when alarm being triggered" max="1" min="0" size="1" type="list" value="1">
<Help></Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value genre="config" index="32" instance="1" label="Level of low battery" max="50" min="10" size="1" type="byte" value="20">
<Help>This parameter defines a battery level as the "low battery".</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" label="Lifeline" max_associations="5"/>
<Group index="2" label="BASIC SET command" max_associations="5"/>
</Associations>
</CommandClass>
</Product>
You can’t perform that action at this time.