<Product Revision="8" xmlns="https://github.com/OpenZWave/open-zwave">
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/019B:0001:0001</MetaDataItem>
<MetaDataItem name="ProductPic">images/thermofloor/heatit021.png</MetaDataItem>
<MetaDataItem id="0001" name="ZWProductPage" type="0001">https://products.z-wavealliance.org/products/1234/</MetaDataItem>
<MetaDataItem name="Description">Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that
can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others.
The display will show the actual room temperature. By pressing the buttons, the display will show the set value.
Heatit Z-Wave is equipped with a single-pole switch.
The thermostat can handle loads up to 16A/3600Wat 230V. If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors.
FUNCTIONS
• Room sensor
• Floor sensor
• Temperature limiter
• Power regulator
• Z-Wave chip 500 series
• Week program/setback temperature via gateway
• Setback mode
• 7-segment LCD-screen
• Can be used in connection with diff erent NTC-sensors
• Lock mode/child lock
• Backlight
• Calibration
• 8 scenarios
CONNECTION CLAMPS
Use 1,5 mm² or 2,5 mm² cables according to power need.
TECHNICAL DATA
Rated voltage: 230V 50/60Hz
Max. load: 3600W
Max. current: 16A
Power consumption: 1,5W
Protection class: IP21
Min/Max installation temp: -20°C to 40°C
Min/Max operating temp: 5°C to 40°C
Temperature intervals: Floor sensor 5°C to 40°C
Room sensor 5°C to 40°C
Hysteresis: 0,5°C
Sensor values: 0°C 29,1 kOhm
10°C 18,6 kOhm
15°C 15,1 kOhm
20°C 12,2 kOhm
25°C 10,0 kOhm
Switch: Single-pole</MetaDataItem>
<MetaDataItem name="ExclusionDescription">INCLUSION/EXCLUSION
To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.
The display will show OFF. Press Right (down) 4 times till you see Con in the display.
Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately
2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion
fails, Err (error) will appear.
Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings.</MetaDataItem>
<MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/1234/Manual_Multireg Z-Wave_Ver2015-A.pdf</MetaDataItem>
<MetaDataItem id="0001" name="FrequencyName" type="0001">CEPT (Europe)</MetaDataItem>
<MetaDataItem name="Name">Heatit Z-Wave</MetaDataItem>
<MetaDataItem id="0001" name="Identifier" type="0001">TF021</MetaDataItem>
<MetaDataItem name="ResetDescription">FACTORY RESET - RES
By pressing buttons Left and Center (up and confirm) for 20 seconds, the thermostat will perform a complete factory reset.
NB! Please use this procedure only when the primary controller is missing or otherwise inoperable.</MetaDataItem>
<MetaDataItem name="InclusionDescription">INCLUSION/EXCLUSION
To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.
The display will show OFF. Press Right (down) 4 times till you see Con in the display.
Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately
2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion
fails, Err (error) will appear.
Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings.</MetaDataItem>
<MetaDataItem name="WakeupDescription">If Er2 appears in the display, touch any button to restart the display.</MetaDataItem>
<ChangeLog>
<Entry author="Justin Hammond - Justin@dynam.ac" date="08 May 2019" revision="7">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1182/xml</Entry>
<Entry author="Justin Hammond - Justin@dynam.ac" date="08 May 2019" revision="8">Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1234/xml</Entry>
</ChangeLog>
</MetaData>
<CommandClass id="64">
<Value genre="user" index="0" instance="1" label="Mode" max="0" min="0" read_only="false" size="1" type="list" units="" value="0" write_only="false">
<Item label="Off" value="0"/>
<Item label="Heat (Default)" value="1"/>
<Item label="Cool" value="2"/>
<Item label="Energy Heat" value="11"/>
</Value>
<SupportedModes>
<Mode index="0" label="Off"/>
<Mode index="1" label="Heat"/>
<Mode index="2" label="Cool"/>
<Mode index="11" label="Energy Heat"/>
</SupportedModes>
<Compatibility/>
</CommandClass>
<CommandClass id="67">
<Instance index="1"/>
<Value genre="user" index="1" instance="1" label="Heating" max="40" min="5" read_only="false" type="decimal" units="C" value="20" write_only="false"/>
<Value genre="user" index="2" instance="1" label="Cooling" max="40" min="5" read_only="false" type="decimal" units="C" value="21" write_only="false"/>
<Value genre="user" index="11" instance="1" label="Energy Heat" max="40" min="5" read_only="false" type="decimal" units="C" value="16" write_only="false"/>
<Compatibility>
<Base>0</Base>
<CreateVars>true</CreateVars>
</Compatibility>
</CommandClass>
<CommandClass id="112">
<Value genre="config" index="1" label="Operation mode" size="1" type="list" value="1">
<Item label="Off" value="0"/>
<Item label="Heat" value="1"/>
<Item label="Cool" value="2"/>
<Item label="Energy save heat" value="11"/>
</Value>
<Value genre="config" index="2" label="Temperature sensor" size="1" type="list" value="1">
<Item label="F - Floor mode" value="0"/>
<Item label="A - Room temperature mode" value="1"/>
<Item label="AF - Room mode w/floor limitations" value="2"/>
<Item label="A2 - Room temperature mode" value="3"/>
<Item label="P - Power regulator" value="4"/>
<Item label="FP - Floor mode with minimum power limitation" value="5"/>
</Value>
<Value genre="config" index="3" label="Floor sensor type" size="1" type="list" value="0">
<Item label="10k ntc" value="0"/>
<Item label="12k ntc" value="1"/>
<Item label="15k ntc" value="2"/>
<Item label="22k ntc" value="3"/>
<Item label="33k ntc" value="4"/>
<Item label="47k ntc" value="5"/>
</Value>
<Value genre="config" index="4" label="DIFF l. Temperature control Hysteresis" max="30" min="3" size="2" type="short" value="5">
<Help>3-30 (0.3C - 3.0C)</Help>
</Value>
<Value genre="config" index="5" label="FLo: Floor min limit" max="400" min="50" size="2" type="short" value="50">
<Help>50-400 (5.0C - 40.0C)</Help>
</Value>
<Value genre="config" index="6" label="FHi: Floor max limit" max="400" min="50" size="2" type="short" value="400">
<Help>50-400 (5.0C - 40.0C)</Help>
</Value>
<Value genre="config" index="7" label="ALo: Air min limit" max="400" min="50" size="2" type="short" value="50">
<Help>50-400 (5.0C - 40.0C)</Help>
</Value>
<Value genre="config" index="8" label="AHi: Air max limit" max="400" min="50" size="2" type="short" value="400">
<Help>50-400 (5.0C - 40.0C)</Help>
</Value>
<Value genre="config" index="9" label="PLo: Min temperature in Power Reg Mode" max="9" min="0" size="1" type="byte" value="0">
<Help>0-9. Min temperature in Power Regulator Mode (setting 2. Temperature sensor - P)</Help>
</Value>
<Value genre="config" index="10" instance="1" label="CO mode setpoint" max="400" min="50" size="2" type="short" value="210">
<Help>50-400 (5.0C - 40.0C)</Help>
</Value>
<Value genre="config" index="11" instance="1" label="ECO mode setpoint" max="400" min="50" size="2" type="short" value="180">
<Help>50-400 (5.0C - 40.0C)</Help>
</Value>
<Value genre="config" index="12" label="P setting" max="10" min="0" size="2" type="short" value="2">
<Help>0-10</Help>
</Value>
<Value genre="config" index="13" instance="1" label="COOL setpoint" max="400" min="50" size="2" type="short" value="180">
<Help>
Only if cooling is enabled.
50-400 (5.0C - 40.0C)
</Help>
</Value>
<Compatibility/>
</CommandClass>
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" label="Lifeline" max_associations="1"/>
<Group index="2" label="On/Off control" max_associations="8"/>
</Associations>
<Compatibility/>
</CommandClass>