From 4c76375e96a86e360cf5556e29e58bcc727ddb31 Mon Sep 17 00:00:00 2001 From: Eirik H Date: Mon, 30 Sep 2019 11:52:22 +0200 Subject: [PATCH] Update Idlock 150 config file for 1.6 firmware (#1917) * Set idlock product name as specified in wiki/docs * Use spaces instead of tabs in idlock150.xml * Update formatting of the idlock150.xml metadata section * Update idlock config params * Fix disabled value --- config/idlock/idlock150.xml | 184 +++++++++++++++++-------------- config/manufacturer_specific.xml | 2 +- 2 files changed, 101 insertions(+), 85 deletions(-) diff --git a/config/idlock/idlock150.xml b/config/idlock/idlock150.xml index 3e125fd210..44c85fbe30 100644 --- a/config/idlock/idlock150.xml +++ b/config/idlock/idlock150.xml @@ -1,35 +1,35 @@ - + - http://www.openzwave.com/device-database/0373:0001:0003 - images/idlock/idlock150.png - https://products.z-wavealliance.org/products/2780/ - https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/2780/IDLock150_ZWave_UserManual_v2.1.pdf - Exclusion – (Puts your device in exclusion mode) + ID Lock 150 Z-Wave module + A module enabling your ID Lock digital door lock to a Z-Wave Plus enabled digital door Lock. -• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). -• Release button. -• Enter Master PIN followed by * on touch panel. -• Press digit "2" for settings followed by * on touch panel. -• Press digit “5” on touch panel. +The module is compatible with ID Lock 101 and ID Lock 150. -Exclusion mode starts immediately. LED indicator below logo signals this by flashing blue. +It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications. + http://www.openzwave.com/device-database/0373:0001:0003 + https://idlock.no/z-wave/ + https://idlock.no/kundesenter/ + images/idlock/idlock150.png + https://idlock.no/wp-content/uploads/2019/08/IDLock150_ZWave_UserManual_v3.02.pdf + Activate by touching the touch panel with finger(s), the palm of the hand on the outside unit or by pushing the key button on the inside unit. Inclusion – (Puts your device in inclusion mode) -• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). -• Release button. -• Enter Master PIN followed by * on touch panel. -• Press digit "2" for settings followed by * on touch panel. -• Press digit “5” on touch panel. +• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). +• Release button. +• Enter Master PIN followed by * on touch panel. +• Press digit "2" for settings followed by * on touch panel. +• Press digit “5” on touch panel. Inclusion mode starts immediately. LED indicator below logo signals this by flashing blue. - A module enabling your ID Lock digital door lock to a Z-Wave Plus enabled digital door Lock. + Exclusion – (Puts your device in exclusion mode) -The module is compatible with ID Lock 101 and ID Lock 150. +• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state). +• Release button. +• Enter Master PIN followed by * on touch panel. +• Press digit "2" for settings followed by * on touch panel. +• Press digit “5” on touch panel. -It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications. - CEPT (Europe) - Activate by touching the touch panel with finger(s), the palm of the hand on the outside unit or by pushing the key button on the inside unit. - ID-150 +Exclusion mode starts immediately. LED indicator below logo signals this by flashing blue. Device reset – (This will reset RF interface module to factory default settings) Warning: Please do only proceed with the following reset procedure, if primary network controller is missing or otherwise inoperable. @@ -45,62 +45,57 @@ If the Z-wave module is not included in a Z-wave network the door lock will also FACTORY RESET DOOR LOCK FIRMWARE: -• Push and hold inside lock/unlock button while inserting the fourth battery. -• Receive reset sound. -• Release button. -• Receive confirmation sound. - - ID Lock 150 Z-Wave module +• Push and hold inside lock/unlock button while inserting the fourth battery. +• Receive reset sound. +• Release button. +• Receive confirmation sound. + https://products.z-wavealliance.org/products/2780/ + CEPT (Europe) + ID-150 Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2780/xml + Update as per the 1.4.9/1.6 firmware specification - + - Door Lock Mode - Autolock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode - Default Value : 1 ( Disable Away / Auto Lock Mode ) - - - - - + Door Lock Mode + Autolock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode + Default Value : 1 ( Auto lock, Away off ) + + + + + - + - RFID Registration Configuration - IDLocks can use up to 50 RFID cards. In order to use a RFID, RFID has to be registered by z-wave configuration command class. - - RFID Configuration with Z-wave is only valid for ID Lock 101. - - Configuration Parameters are as below. Default value is 0x05 (Not in progress). - ID Lock 150 will always report 0x05 as this feature is not supported by this door lock model. - - Configuration Set in case of starting to register from gateway - - - - - + RFID Mode + RFID activated + RFID deactivated + Default Value: 5 (RFID activated) + + + - + - Door Hinge Position - Default Value : 0 (Right Handle) - - - + Door Hinge Position + Default Value : 0 (Right hinged operation) + + + - + - Door Audio Volume Level - This parameter is a set only parameter. If the value is changed locally on the door lock, this value will not change. - Default Value : 5 - + Door Audio Volume Level + This parameter is a set only parameter. If the value is changed locally on the door lock, this value will not change. + Default Value : 5 + @@ -111,19 +106,21 @@ FACTORY RESET DOOR LOCK FIRMWARE: - Door ReLock Mode - Default Value: 1 (Enabled) - + Door ReLock Mode + Default Value: 1 (Enabled) + - Service PIN Mode - A configuration get command on this parameter returns the latest set parameter value (set by Z-wave). - This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5, 6 and 7 are for future use on door lock. - Default Value: 0 (Deactivated) - + Service PIN Mode + A configuration get command on this parameter returns the latest set parameter value (set by Z-wave). + This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5 and 6 are for future use on door lock. + Disabled: Disables both PIN and Service PIN menu on door lock + + Default Value: 0 (Deactivated) + @@ -131,29 +128,48 @@ FACTORY RESET DOOR LOCK FIRMWARE: - + + - Door Lock Model Type - This configuration is only accepted by configuration get command - It is a read only parameter. Default value depends on the door lock model type. - + Door Lock Model Type + This configuration is only accepted by configuration get command + It is a read only parameter. Default value depends on the door lock model type. + + + + + Updater Mode + + Enables use of the Updater app. + Default Value: 0 (Off, no sound) + + + + + + + + + Master PIN Unlock Mode + + + - Configuration Report for retriving the RFID information - Byte 1: Para1 (msb) - Byte 2: Para2 - Byte 3: Para3 - Byte 4: Para4 (lsb) - + Configuration Report for retriving the RFID information + Byte 1: Para1 (msb) + Byte 2: Para2 + Byte 3: Para3 + Byte 4: Para4 (lsb) + - diff --git a/config/manufacturer_specific.xml b/config/manufacturer_specific.xml index 58207d5574..496937a7fd 100644 --- a/config/manufacturer_specific.xml +++ b/config/manufacturer_specific.xml @@ -929,7 +929,7 @@ - +