Update tz74.xml

  • Loading branch information...
dav76df committed Jun 5, 2018
1 parent ff75c48 commit 50e20b2cfbacb4bdad89e95bf3edde90f22ee5d9
Showing with 15 additions and 6 deletions.
  1. +15 −6 config/wenzhou/tz74.xml
@@ -3,15 +3,24 @@
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Night light" min="0" max="1" value="1">
<Help>The LED on the TZ56D will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 1.</Help>
<Value type="list" genre="config" instance="1" index="1" label="Night light" min="0" max="1" value="1" size="1">
<Help>The LED on the TZ74 will by default, turn ON when the load attached is turned OFF. To make the LED turn ON when the load attached is turned ON instead, set parameter to a value of 0.</Help>
<Item label="The LED is ON when the load is ON" value="0" />
<Item label="The LED is ON when the load is OFF" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Memory Function" min="0" max="1" value="1">
<Help>Stated in the above form,switch by default value is 1,when the value is 0,switch memory function not open; when the value is 1,open switch memory function</Help>

<Value type="list" genre="config" instance="1" index="2" label="Memory Function" min="0" max="1" value="1" size="1">
<Help>switch memory function</Help>
<Item label="no switch memory function" value="0" />
<Item label="The socket status is same as before when power ON" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Invert switch" min="0" max="1" value="0">
<Help>To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1.</Help>

<Value type="list" genre="config" instance="1" index="3" label="Invert switch" min="0" max="1" value="0" size="1">
<Help>Change the top of the switch to OFF or ON , set parameter 4 to 1.</Help>
<Item label="The top of the switch is ON" value="0" />
<Item label="The top of the switch is OFF" value="1" />
</Value>

<Value type="list" genre="config" instance="1" index="4" label="Edge or Pulse mode" min="1" max="3" value="3" size="1">
<Help>switch mode</Help>
<Item label="Edge Mode" value="1" />