Permalink
Browse files

Add Zooz ZEN07 Mini Plug from DeviantEng

close #998
  • Loading branch information...
nechry committed Oct 5, 2016
1 parent 183a189 commit 55810a9eb615d08497f7d334eefd38c87afc4558
Showing with 71 additions and 0 deletions.
  1. +1 −0 ChangeLog
  2. +3 −0 config/manufacturer_specific.xml
  3. +66 −0 config/zooz/zen07.xml
  4. +1 −0 distfiles.mk
@@ -111,6 +111,7 @@ Version 1.5
- Add FortrezZ WV-01 Automated Water Shut-Off Valve (Nechry)
- Pull Request #992 - Devolo Metering Plug and Permundo Plugs from tobiasgraf (Nechry)
- Add configuration file for First Alert ZCombo Smoke and Carbon Monoxide Detector (Nechry)
- Add Zooz ZEN07 Mini Plug from DeviantEng (Nechry)

Version 1.4
- Released 10th Jan, 2016
@@ -965,6 +965,9 @@
<Product type="0002" id="0002" name="RGBW LED Bulb" config="zipato/RGBBulb.xml" />
<Product type="6131" id="4501" name="Zipato Mini Keypad" config="zipato/MiniKeypad.xml" />
</Manufacturer>
<Manufacturer id="027a" name="Zooz">
<Product type="0003" id="0087" name="ZEN07 Mini Plug" config="zooz/zen07.xml"/>
</Manufacturer>
<Manufacturer id="0021" name="Zykronix">
</Manufacturer>
</ManufacturerSpecificData>
@@ -0,0 +1,66 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Zooz ZEN07 Mini Plug -->

<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="list" genre="config" index="1" label="Metering Reports" size="1" min="0" max="1" value="1">
<Help>Choose if you want the Mini Plug to send metering reports to the controller.</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="short" genre="config" index="2" label="Metering Reports Interval" size="2" min="1" max="65535" value="300" units="seconds">
<Help>Choose how often you want the Mini Plug to send metering reports to the controller, in seconds.</Help>
</Value>
<Value type="byte" genre="config" index="6" label="Power Reporting Percentage Threshold" unit="%" size="1" min="1" max="100" value="5" units="percentage">
<Help>Percentage change of elecricity, voltage, power consumption, or energy before report is sent.
Defaults to 5%.</Help>
</Value>
<Value type="byte" genre="config" index="3" label="Overload Protection" unit="Amperes" size="1" min="1" max="16" value="13" units="Amperes">
<Help>Use this parameter to adjust the max amount of electricity you want your Mini Plug to handle, by Amperes.
Defaults to 13A.</Help>
</Value>
<Value type="byte" genre="config" index="4" label="LED Notifications - Heavy Load" unit="Amperes" size="1" min="1" max="13" value="12" units="Amperes">
<Help>Use this parameter to adjust the LED Notification for Heavy Load by setting a threshold of Amperes.
Must be lower than Parameter #3.
Defaults to 12A</Help>
</Value>
<Value type="list" genre="config" index="5" label="LED Notifications" size="1" min="0" max="1" value="1">
<Help>Use this parameter to turn LED notifications on or off.</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="list" genre="config" index="7" label="On/Off Status After Power Failure" size="1" min="0" max="1" value="1">
<Help>Choose the recovery state for the Mini Plug if power outage occurs. Off sets the state to "OFF" once power is restored.
Resume sets the state to the previous state prior to the outage.
Defaults to Resume.</Help>
<Item label="Off" value="0"/>
<Item label="Resume" value="1"/>
</Value>
<Value type="list" genre="config" index="8" label="Auto Turn-Off Timer" size="1" min="0" max="1" value="0">
<Help>Use this parameter to enable or disable the auto turn-off timer function.
If enabled, the Mini Plug will automatically turn off after a fixed period of time, set in Parameter #9.
Defaults to Disabled.</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="short" genre="config" index="9" label="Auto Turn-Off Timer Interval" unit="minutes" size="2" min="1" max="65535" value="150">
<Help>Use this parameter to set the time, in minutes, after which the Mini Plug should turn off if Auto Turn-Off Timer is Enabled (Parameter #8).
Defaults to 150 minutes.</Help>
</Value>
<Value type="list" genre="config" index="10" label="Manual Control" size="1" min="0" max="1" value="1">
<Help>Choose if you want the Z-Wave button to turn the Mini Plug on or off manually, or if you want to disable this function. Defaults to Enabled.</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
</CommandClass>

<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" max_associations="5" label="Lifeline"/>
<Group index="2" max_associations="5" label="Status"/>
<Group index="3" max_associations="5" label="Notifications"/>
</Associations>
</CommandClass>
</Product>
@@ -305,6 +305,7 @@ DISTFILES = .gitignore \
config/widom/WDS.xml \
config/zipato/MiniKeypad.xml \
config/zipato/RGBBulb.xml \
config/zooz/zen07.xml \
config/zwave.me/ZME_05431.xml \
config/zwave.me/ZME_06433.xml \
config/zwave.me/ZME_06436.xml \

0 comments on commit 55810a9