@@ -172,7 +172,7 @@ Default setting: 15</Help>
<Value type="list" genre="config" instance="1" index="37" label="Behaviour of the Dimmer after OVERCURRENT or SURGE" size="1" value="1">
<Help>Behaviour of the Dimmer after OVERCURRENT or SURGE</Help>
<Item label="device permanently disabled until re-enabling by comand or external switch" value="0" />
<Item label="three atempts to turn on the load" value="1" />
<Item label="three attempts to turn on the load" value="1" />
</Value>
<Value type="short" genre="config" instance="1" index="38" label="Brightness level correction for flickering loads" min="0" max="255" value="255">
<Help>Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable lEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Available settings: 0 - automatic correction disabled 1-254 - duration of correction in seconds 255 - automatic correction always enabled Default setting: 255</Help>
@@ -34,7 +34,7 @@
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="15" label="Second channel - operating mode" value="0" size="1">
<Help>This parameter allows to choose operating for the 2st channel controlled by the S2 switch.</Help>
<Help>This parameter allows to choose operating for the 2nd channel controlled by the S2 switch.</Help>
<Item label="Standard operation" value="0"/>
<Item label="Delay On" value="1"/>
<Item label="Delay Off" value="2"/>
@@ -139,7 +139,7 @@
<Item label="illumination turned off completely" value="9" />
</Value>

<Value type="short" genre="config" instance="1" index="70" label="Oveload safety switch" value="65535" size="2">
<Value type="short" genre="config" instance="1" index="70" label="Overload safety switch" value="65535" size="2">
<Help>This function allows for turning off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if "always on" function is active (parameter 1). Controlled device can be turned back on via B-button or sending a control frame. By default this function is inactive. Default setting: 65535 (6553,5W) Available settings: 10 - 65535 (1W - 6553,5W). Value higher than 32000 (3200W) turns the overload safety switch off, i.e. this functionality is turned off by default. Default setting: 65535 (6553,5W)</Help>
</Value>
</CommandClass>
@@ -0,0 +1,15 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>

<!-- https://products.z-wavealliance.org/products/1787 -->
<!-- No configuration parameters -->
<!-- Association Groups -->

<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="1" label="Lifeline"/>
<Group index="2" max_associations="12" label="Slave Shades"/>
</Associations>
</CommandClass>

</Product>
@@ -0,0 +1,15 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>

<!-- https://products.z-wavealliance.org/products/17876-->
<!-- No configuration parameters -->
<!-- Association Groups -->

<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="1" label="Lifeline"/>
<Group index="2" max_associations="12" label="Slave Shades"/>
</Associations>
</CommandClass>

</Product>
@@ -0,0 +1,54 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Hank HKZW-MS02 Multisensor
http://products.z-wavealliance.org/products/2578
https://products.z-wavealliance.org/ProductManual/File?folder=&filename=Manuals/2578/HKZW-MS02-ProductManual.pdf
Config capabilities: https://products.z-wavealliance.org/products/2578/configs
-->
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="12" label="Motion sensor's sensitivity" units="%" size="1" min="0" max="8" value="8">
<Help>
Level 1 to 8. The higher the value, the more sensitive the PIR sensor.
0 Disabled.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="14" label="Enable/disable basic set command" size="1" min="0" max="1" value="0">
<Help>Enable/disable basic set command</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="15" label="Value of the basic set" size="1" min="0" max="1" value="0">
<Help>
Send basic set value = 255 to nodes associated with group 2 when motion alarm is triggered. Send basic set value = 0 to nodes associated with group 2 when motion alarm is canceled.
Send basic set value = 0 to nodes associated with group 2 when motion alarm is triggered. Send basic set value = 255 to nodes associated with group 2 when motion alarm is canceled.</Help>
<Item label="Basic On" value="0"/>
<Item label="Basic Off" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="17" label="Enable/disable shock alarm" size="1" min="0" max="1" value="0">
<Help>when the value is 0, the product will not sends a vibration alarm after moving or shaking; when the value is 1, the product will sends a vibration alarm after moving or shaking</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value type="short" genre="config" instance="1" index="18" label="Motion alarm cancellation delay" units="lux" size="2" min="0" max="65535" value="200">
<Help>
0 Reports are not sent.
1 to 65535 the change in luminance level resulting in luminance report being sent to the main controller.
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="32" label="Level of low battery" units="%" size="1" min="10" max="50" value="20">
<Help>The low level from 10% to 50%</Help>
</Value>

</CommandClass>

<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="5" label="Lifeline"/>
<Group index="2" max_associations="5" label="Basic set command"/>
</Associations>
</CommandClass>

</Product>
@@ -0,0 +1,59 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
HomeSeer Motion Sensor HS-MS100+
https://products.z-wavealliance.org/products/2729
-->
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="list" index="12" genre="config" label="Motion Sensor Sensitivity" min="0" max="8" size="1" value="8">
<Help>Motion Sensor Sensitivity. 0 - Sensor is OFF, 8 - Max sensitivity.</Help>
<Item label="OFF" value="0"/>
<Item label="1" value="1"/>
<Item label="2" value="2"/>
<Item label="3" value="3"/>
<Item label="4" value="4"/>
<Item label="5" value="5"/>
<Item label="6" value="6"/>
<Item label="7" value="7"/>
<Item label="8" value="8"/>
</Value>
<Value type="list" index="14" genre="config" label="Basic Set Command" min="0" max="1" size="1" value="0">
<Help>Enable / disable the basic set command send to group 2</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="list" index="15" genre="config" label="Value for Basic Set Command" units="" min="0" max="1" size="1" value="0">
<Help>
Define BASIC SET VALUE to nodes associated with group 2 when motion alarm is triggered and is canceled.
</Help>
<Item label="255 alarm is triggered, 0 alarm is canceled" value="0"/>
<Item label="0 alarm is triggered, 255 alarm is canceled" value="1"/>
</Value>
<Value type="list" index="17" genre="config" label="Shock Sensor" min="0" max="1" size="1" value="0">
<Help>when the value is Disable, the product will not sends a vibration alarm after moving or shaking;
when the value is Enable, the product will sends a vibration alarm after moving or shaking</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="short" index="18" genre="config" label="Motion Timeout Interval" units="seconds" min="0" max="65525" value="600">
<Help>Motion Timeout Interval, seconds</Help>
</Value>
<Value type="list" index="32" genre="config" label="Low battery threshold" units="%" min="0" max="50" size="1" value="20">
<Help>Low battery reporting threshold, %</Help>
<Item label="0" value="0"/>
<Item label="10" value="10"/>
<Item label="20" value="20"/>
<Item label="30" value="30"/>
<Item label="40" value="40"/>
<Item label="50" value="50"/>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="5" label="Lifeline"/>
<Group index="2" max_associations="5" label="Basic Set"/>
</Associations>
</CommandClass>
</Product>
18 config/inovelli/nzw31.xml 100755 → 100644
@@ -1,12 +1,13 @@
<?xml version="1.0" encoding="utf-8"?>
<!-- Inovelli Dimmer NZW31 -->
<Product xmlns="http://code.google.com/p/open-zwave/">
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value genre="config" index="1" label="Dimming/Brightening Step Level" min="1" max="99" value="1" size="1" type="byte">
<Help>Each step of the dimming process will increase or decrease the brightness by this percentage. Increasing this will make the transition time quicker.</Help>
<Value genre="config" index="1" label="Dimming/Brightening Step Level" min="1" max="99" units="%" value="1" size="1" type="byte">
<Help>Each step of the dimming process will increase or decrease the brightness by this percentage. Increasing this will make the transition time quicker. Range 1-99%</Help>
</Value>
<Value genre="config" index="2" label="Minimum Dimming Level" min="1" max="99" value="1" size="1" type="byte">
<Help>This is the minimum value to which the switch will dim. Useful for CFL or LED lights that otherwise won't come on or come on but flicker/buzz.</Help>
<Value genre="config" index="2" label="Minimum Dimming Level" min="1" max="99" units="%" value="1" size="1" type="byte">
<Help>This is the minimum value to which the switch will dim. Useful for CFL or LED lights that otherwise won't come on or come on but flicker/buzz. Range 1-99%</Help>
</Value>
<Value genre="config" index="3" value="0" label="LED Indicator Control" units="" size="1" min="0" max="255" type="list">
<Help>Choose if you want the LED indicator to turn on when switch is on or off or disable completely.</Help>
@@ -20,7 +21,7 @@
<Item value="1" label="Inverted"/>
</Value>
<Value genre="config" index="5" value="0" label="Automatically turn switch off after interval" units="seconds" size="2" min="0" max="32767" type="short">
<Help>Automatically turn the switch off after this many seconds. 0 is disabled</Help>
<Help>Automatically turn the switch off after this many seconds. 0 is disabled, or up to 32767 seconds</Help>
</Value>
<Value genre="config" index="8" value="0" label="Default value when turned on at switch" min="0" max="99" size="1" type="byte">
<Help>Default brightness when switch is turned on locally. 0 is previous. Firmware 1.02+"</Help>
@@ -36,5 +37,10 @@
<Group index="1" label="Lifeline" max_associations="5" />
</Associations>
</CommandClass>

<CommandClass id="91" name="COMMAND_CLASS_CENTRAL_SCENE" version="1" request_flags="4" scenecount="0">
<Instance index="1" />
<Value type="int" genre="system" instance="1" index="0" label="Scene Count" units="" read_only="true" write_only="false" verify_changes="false" min="-2147483648" max="2147483647" value="2" />
<Value type="int" genre="user" instance="1" index="1" label="Bottom Button Scene" units="" read_only="false" write_only="false" verify_changes="false" min="-2147483648" max="2147483647" value="1" />
<Value type="int" genre="user" instance="1" index="2" label="Top Button Scene" units="" read_only="false" write_only="false" verify_changes="false" min="-2147483648" max="2147483647" value="1" />
</CommandClass>
</Product>