<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Hank HKZW-FLD01 Flood Sensor
https://products.z-wavealliance.org/products/2641
-->

<!-- Configuration -->
<CommandClass id="112">
<Value type="list" genre="config" instance="1" index="14" label="Enable/Disable BASIC SET command" size="1" min="0" max="1" value="0">
<Help>The Flood sensor can send BASIC SET command to nodes associated with group 2.</Help>
<Item value="0" label="Disable"/>
<Item value="1" label="Enable"/>
</Value>
<Value type="list" genre="config" instance="1" index="15" label="Value of the BASIC SET" size="1" min="0" max="1" value="0">
<Help>The Flood sensor can reverse its value of BASIC SET when flooding is triggered.</Help>
<Item value="0" label="Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled."/>
<Item value="1" label="Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled."/>
</Value>
<Value type="list" genre="config" instance="1" index="17" label="Enable/Disable flooding alarm" size="1" min="0" max="1" value="1">
<Help></Help>
<Item value="0" label="Disable"/>
<Item value="1" label="Enable"/>
</Value>
<Value type="list" genre="config" instance="1" index="18" label="Enable/Disable shock alarm" size="1" min="0" max="1" value="0">
<Help></Help>
<Item value="0" label="Disable"/>
<Item value="1" label="Enable"/>
</Value>
<Value type="list" genre="config" instance="1" index="19" label="Enable/Disable high temperature alarm" size="1" min="0" max="1" value="0">
<Help></Help>
<Item value="0" label="Disable"/>
<Item value="1" label="Enable"/>
</Value>
<!-- what default value? -->
<Value type="short" genre="config" instance="1" index="20" label="Set the high temperature alarm trigger value" size="2" min="-670" max="2570">
<Help>US: -670 - 2570 (-67 - 257 F)
Other: -550 - 1250 (-55 - 125 C)</Help>
</Value>
<Value type="list" genre="config" instance="1" index="21" label="Enable/Disable low temperature alarm" size="1" min="0" max="1" value="0">
<Help></Help>
<Item value="0" label="Disable"/>
<Item value="1" label="Enable"/>
</Value>
<Value type="short" genre="config" instance="1" index="22" label="Set the low temperature alarm trigger value" size="2" min="-670" max="2570" value="0">
<Help>US: -670 - 2570 (-67 - 257 F)
Other: -550 - 1250 (-55 - 125 C)</Help>
</Value>
<Value type="list" genre="config" instance="1" index="24" label="Enable/Disable blinking LED when alarm being triggered" size="1" min="0" max="1" value="1">
<Help></Help>
<Item value="0" label="Disable"/>
<Item value="1" label="Enable"/>
</Value>
<Value type="byte" genre="config" instance="1" index="32" label="Level of low battery" size="1" min="10" max="50" value="20">
<Help>This parameter defines a battery level as the "low battery".</Help>
</Value>
</CommandClass>

<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="5" label="Lifeline"/>
<Group index="2" max_associations="5" label="BASIC SET command"/>
</Associations>
</CommandClass>

</Product>
@@ -638,6 +638,7 @@
<Product type="0100" id="0004" name="HKZW-RGB01 RGB bulb" config="hank/hkzw-rgb01.xml"/>
<Product type="0101" id="0004" name="HKZW-RGB01 RGB bulb" config="hank/hkzw-rgb01.xml"/>
<Product type="0101" id="000a" name="HKZW-SO03 Smart Plug" config="hank/hkzw-so03.xml"/>
<Product type="0200" id="000f" name="HKZW-FLD01 Flood Sensor" config="hank/hkzw-fld01.xml"/>
</Manufacturer>
<Manufacturer id="0260" name="Heiman">
<Product type="0168" id="0168" name="Door Sensor HS1DS-Z" config="heiman/HS1DS-Z.xml"/>
@@ -251,6 +251,7 @@ DISTFILES = .gitignore \
config/greenwave/powernode1.xml \
config/greenwave/powernode6.xml \
config/hank/hkzw-dws01.xml \
config/hank/hkzw-fld01.xml \
config/hank/hkzw-ms01.xml \
config/hank/hkzw-rgb01.xml \
config/hank/hkzw-so01-smartplug.xml \

0 comments on commit be34693

Please sign in to comment.
You can’t perform that action at this time.