Basic status of the node Enable/Disable LED indicator when plugged in 1~10, other= ignore. A total of 10 levels, level 1 as the weak output power, and so on, 10 for most output power level Lock/ unlock all configuration parameters Reset to the default configuration Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number The Current Level of the Device The Current Level of the Device Increase the Brightness of the Device Increase the Brightness of the Device Decrease the Brightness of the Device Decrease the Brightness of the Device Ignore the Start Level of the Device when increasing/descreasing brightness Ignore the Start Level of the Device when increasing/descreasing brightness Start Level when Changing the Brightness of a Device Start Level when Changing the Brightness of a Device Duration taken when changing the Level of a Device How Many Percent Change when incrementing/decrementing the Level of a Device Increment the Level of a Device Decrement the Level of a Device Switch All Devices On/Off Power Sensor Value ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the User Application Icon File to use for the User Application Parameter is set automatically during the calibration process. Options for changing parameter 1-98. Default 1. Parameter is set automatically during the calibration process. Options for changing parameter 2-99. Default 99. Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. Options for changing parameter 1-99. Default 1. This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. Available settings: 0-255 (0s - 25,5s) Available settings: 1-99 Default: 1 Available settings: 0-255 (0s - 2,55s) Default setting: 1 Available settings: 1-99 Default: 1 Available settings: 0-255 (0s - 2,55s) Default setting: 1 Saving state before power failure. Default 1. Available settings: 0 - Function disabled; 1-32767 - time to turn off measured in seconds (1s - 9,1h) Default setting: 0 Enable/Disable ALL ON/OFF. Default 255. Changing value of this parameter will force the calibration process. This parameter determines operating mode of the Dimmer (automatic/manual settings). Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR. Available settings: 0 - function disabled; 1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb) Default setting: 30 Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer). Available settings: 0 - detection of a burnt out bulb disabled; 1-255 - delay time in seconds; Default setting: 5 If the parameter is active, switching on the Dimmer (S1 single click) will always set this brightness level. Available settings: 0 - function disabled; 1-99 - percentage level of brightness; Default setting: 0 This parameter allows to choose mode of 1st input (IN1). Change it depending on connected device. This parameter allows to choose mode of 2nd input (IN2). Change it depending on connected device. Double-click set lighting at 100%. Default 1. This parameter allows reversing operation of IN1 and IN2 inputs without changing the wiring. Use in case of incorrect wiring. This parameter allows reversing operation of OUT1 and OUT2 inputs without changing the wiring. Use in case of incorrect wiring. Switch no. 2 controls the Dimmer additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch) After smart plug being included into a Z-Wave network, the LED in the device will indicator the state of load. 0 - The LED will follow the status(on/off) of its load 1 - When the state of Switch's load changed, The LED will follow the status(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. SCENE ID depends on the switch type configurations. Default 0. Forced auto-calibration will set this parameter value to 2. Load control mode recognized during auto-calibration. Load control mode recognized during auto-calibration. Dimmability of the load Time required to warm up the filament of halogen bulb. This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc. Behaviour of the Dimmer after OVERCURRENT or SURGE Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable lEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Available settings: 0 - automatic correction disabled 1-254 - duration of correction in seconds 255 - automatic correction always enabled Default setting: 255 Reaching the defined value will result in turning off the load. Additional apparent power limit of 350VA is active by default. Available settings: 0 - functionality disabled; 1-350 - 1W-350W; Default setting: 250 This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 21 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (kvarh), Total Energy (kVAh) This parameter is valid only for Voltage (V of ph1, ph2, ph3), Current (A of ph1, ph2, ph3), Total Power Factor, Total Reactive Power (var) Alarm state may be cancelled earlier, as a result of pressing the switches or sending the Z-Wave command frame. OVERLOAD alarm report (load power consumption too high) LOAD ERROR alarm report (no load, load failure, burnt out bulb) This parameter defines value sent to devices in 2nd association group when IN1 input is triggered (using Basic Command Class). Available settings: 0-255. Default setting: 255. SURGE alarm report (Dimmer output overvoltage) This parameter defines value sent to devices in 2nd association group when IN1 input is deactivated (using Basic Command Class). Available settings: 0-255. Default setting: 255. The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. Available settings: 0 - power reports disabled; 1-100 (1-100%) - power report threshold; Default setting: 10 (10%) This parameter defines value sent to devices in 3rd association group when IN2 input is triggered (using Basic Command Class). Available settings: 0-255. Default setting: 255. Energy level change which will result in sending a new energy report. Available settings: 0 - energy reports disabled; 1-255 (0,01 - 2,55 kWh) - report triggering threshold; Default setting: 10 (0,1 kWh) This parameter defines value sent to devices in 3rd association group when IN2 input is deactivated (using Basic Command Class). Available settings: 0-255. Default setting: 255. This parameter defines how to calculate active power. This parameter is useful in a case of 2-wire connection with light sources other than resistive. The parameter is set to 0 after forced auto-calibration. This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. This parameter works only when parameter 58 has a value other than 0. Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level. Default setting: 0 Heat Alerts Power Management Alerts System Alerts Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Protect a device against unintentional control Z-Wave Library Version Z-Wave Library Version Z-Wave Protocol Version Z-Wave Protocol Version Application Version Application Version Is Communication with Device Encrypted Turn On/Off Device Switch All Devices On/Off Binary Sensor State Binary Sensor State ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the User Application Parameter is set automatically during the calibration process. Options for changing parameter 1-98. Default 1. Parameter is set automatically during the calibration process. Options for changing parameter 2-99. Default 99. Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. Options for changing parameter 1-99. Default 1. Available settings: 0 - Function disabled; 1-32767 - time to turn off measured in seconds (1s - 9,1h) Default setting: 0 Enable/Disable ALL ON/OFF. Default 255. 0 - Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0 Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR. Available settings: 0 - function disabled; 1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb) Default setting: 30 Forced auto-calibration will set this parameter value to 2. This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (kvarh), Total Energy (kVAh) This parameter defines minimal change (from the last reported) of analog input value that results in sending new report. Parameter is relevant only for analog inputs (parameter 20 or 21 set to 4 or 5). Available settings: 0 - (reporting on change disabled). 1-100 (0.1-10V, 0.1V step). Default setting: 5 (0.5V). Set value is added or subtracted to actual measured value by sensor. Available configuration parameters : default value 32536. 32536 offset is 0.0C. From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters : 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Z-Wave Library Version Z-Wave Protocol Version Application Version The Current Level of the Device The Current Level of the Device Increase the Brightness of the Device Increase the Brightness of the Device Decrease the Brightness of the Device Decrease the Brightness of the Device Ignore the Start Level of the Device when increasing/descreasing brightness Ignore the Start Level of the Device when increasing/descreasing brightness Start Level when Changing the Brightness of a Device Start Level when Changing the Brightness of a Device Duration taken when changing the Level of a Device How Many Percent Change when incrementing/decrementing the Level of a Device Increment the Level of a Device Decrement the Level of a Device Switch All Devices On/Off Power Sensor Value ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the User Application Icon File to use for the User Application Parameter is set automatically during the calibration process. Options for changing parameter 1-98. Default 1. Parameter is set automatically during the calibration process. Options for changing parameter 2-99. Default 99. Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources. Options for changing parameter 1-99. Default 1. This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality. Available settings: 0-255 (0s - 25,5s) Available settings: 1-99 Default: 1 Available settings: 0-255 (0s - 2,55s) Default setting: 1 Available settings: 1-99 Default: 1 Available settings: 0-255 (0s - 2,55s) Default setting: 1 Saving state before power failure. Default 1. Available settings: 0 - Function disabled; 1-32767 - time to turn off measured in seconds (1s - 9,1h) Default setting: 0 Enable/Disable ALL ON/OFF. Default 255. Changing value of this parameter will force the calibration process. This parameter determines operating mode of the Dimmer (automatic/manual settings). Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR. Available settings: 0 - function disabled; 1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb) Default setting: 30 Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer). Available settings: 0 - detection of a burnt out bulb disabled; 1-255 - delay time in seconds; Default setting: 5 If the parameter is active, switching on the Dimmer (S1 single click) will always set this brightness level. Available settings: 0 - function disabled; 1-99 - percentage level of brightness; Default setting: 0 This parameter allows to choose mode of 1st input (IN1). Change it depending on connected device. This parameter allows to choose mode of 2nd input (IN2). Change it depending on connected device. Double-click set lighting at 100%. Default 1. This parameter allows reversing operation of IN1 and IN2 inputs without changing the wiring. Use in case of incorrect wiring. This parameter allows reversing operation of OUT1 and OUT2 inputs without changing the wiring. Use in case of incorrect wiring. Switch no. 2 controls the Dimmer additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch) After smart plug being included into a Z-Wave network, the LED in the device will indicator the state of load. 0 - The LED will follow the status(on/off) of its load 1 - When the state of Switch's load changed, The LED will follow the status(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. SCENE ID depends on the switch type configurations. Default 0. Forced auto-calibration will set this parameter value to 2. Load control mode recognized during auto-calibration. Load control mode recognized during auto-calibration. Dimmability of the load Time required to warm up the filament of halogen bulb. This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc. Behaviour of the Dimmer after OVERCURRENT or SURGE Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable lEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. Available settings: 0 - automatic correction disabled 1-254 - duration of correction in seconds 255 - automatic correction always enabled Default setting: 255 Reaching the defined value will result in turning off the load. Additional apparent power limit of 350VA is active by default. Available settings: 0 - functionality disabled; 1-350 - 1W-350W; Default setting: 250 This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 21 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (kvarh), Total Energy (kVAh) This parameter is valid only for Voltage (V of ph1, ph2, ph3), Current (A of ph1, ph2, ph3), Total Power Factor, Total Reactive Power (var) Alarm state may be cancelled earlier, as a result of pressing the switches or sending the Z-Wave command frame. OVERLOAD alarm report (load power consumption too high) LOAD ERROR alarm report (no load, load failure, burnt out bulb) This parameter defines value sent to devices in 2nd association group when IN1 input is triggered (using Basic Command Class). Available settings: 0-255. Default setting: 255. SURGE alarm report (Dimmer output overvoltage) This parameter defines value sent to devices in 2nd association group when IN1 input is deactivated (using Basic Command Class). Available settings: 0-255. Default setting: 255. The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report. Available settings: 0 - power reports disabled; 1-100 (1-100%) - power report threshold; Default setting: 10 (10%) This parameter defines value sent to devices in 3rd association group when IN2 input is triggered (using Basic Command Class). Available settings: 0-255. Default setting: 255. Energy level change which will result in sending a new energy report. Available settings: 0 - energy reports disabled; 1-255 (0,01 - 2,55 kWh) - report triggering threshold; Default setting: 10 (0,1 kWh) This parameter defines value sent to devices in 3rd association group when IN2 input is deactivated (using Basic Command Class). Available settings: 0-255. Default setting: 255. This parameter defines how to calculate active power. This parameter is useful in a case of 2-wire connection with light sources other than resistive. The parameter is set to 0 after forced auto-calibration. This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. This parameter works only when parameter 58 has a value other than 0. Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level. Default setting: 0 Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Protect a device against unintentional control Z-Wave Library Version Z-Wave Library Version Z-Wave Protocol Version Z-Wave Protocol Version Application Version Application Version Is Communication with Device Encrypted Turn On/Off Device Switch All Devices On/Off ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the User Application This parameter allows to choose mode of 1st input (IN1). Change it depending on connected device. This parameter allows to choose mode of 2nd input (IN2). Change it depending on connected device. This parameter allows reversing operation of IN1 and IN2 inputs without changing the wiring. Use in case of incorrect wiring. After smart plug being included into a Z-Wave network, the LED in the device will indicator the state of load. 0 - The LED will follow the status(on/off) of its load 1 - When the state of Switch's load changed, The LED will follow the status(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. This parameter defines the inertia time of IN2 input in alarm modes. Adjust this parameter to prevent bouncing or signal disruptions. Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). Available settings: 1-100 (10ms-1000ms, 10ms step). Default setting: 10 (100ms). This parameter defines additional delay of cancelling the alarm on IN1 input. Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). Available settings: 0 - no delay. 1-3600s. Default setting: 0 (no delay). The interval of sending power report to association device(Group Lifeline). 0 - The function is disabled. The interval of sending power report to association device(Group Lifeline). 0 - The function is disabled. The interval of sending voltage report to association device(Group Lifeline). 0 - The function is disabled. The interval of sending electricity report to association device(Group Lifeline). 0 - The function is disabled. Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Z-Wave Library Version Z-Wave Protocol Version Application Version Turn On/Off Device Switch All Devices On/Off ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the User Application This parameter allows to choose mode of 1st input (IN1). Change it depending on connected device. This parameter allows to choose mode of 2nd input (IN2). Change it depending on connected device. This parameter allows reversing operation of IN1 and IN2 inputs without changing the wiring. Use in case of incorrect wiring. After smart plug being included into a Z-Wave network, the LED in the device will indicator the state of load. 0 - The LED will follow the status(on/off) of its load 1 - When the state of Switch's load changed, The LED will follow the status(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. This parameter defines the inertia time of IN2 input in alarm modes. Adjust this parameter to prevent bouncing or signal disruptions. Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). Available settings: 1-100 (10ms-1000ms, 10ms step). Default setting: 10 (100ms). This parameter defines additional delay of cancelling the alarm on IN1 input. Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). Available settings: 0 - no delay. 1-3600s. Default setting: 0 (no delay). The interval of sending power report to association device(Group Lifeline). 0 - The function is disabled. The interval of sending power report to association device(Group Lifeline). 0 - The function is disabled. The interval of sending voltage report to association device(Group Lifeline). 0 - The function is disabled. The interval of sending electricity report to association device(Group Lifeline). 0 - The function is disabled. Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Z-Wave Library Version Z-Wave Protocol Version Application Version ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Available settings: 1-99 Default: 1 This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (kvarh), Total Energy (kVAh) This parameter is valid only for Voltage (V of ph1, ph2, ph3), Current (A of ph1, ph2, ph3), Total Power Factor, Total Reactive Power (var) This parameter defines a threshold when External IR relay is being turned off. (If Parameter no. 100 is set to the value 1 or 2) This parameter defines a threshold when External relay is being turned off (if the parameter no. 100 is set to the value 1 or 2). External IR relay/ External relay is turned off due to detected overload (as set by parameter 106 and 107) and remains off for a time, defined in this parameter. After that time, the output turns on to check, if the overload is still present. Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Z-Wave Library Version Z-Wave Protocol Version Application Version Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Basic status of the node Turn On/Off Device Turn On/Off Device Binary Sensor State Temperature Sensor Value Temperature Sensor Value Temperature Sensor Value Temperature Sensor Value ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device ZWave+ Version Supported on the Device Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the Installer Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application Icon File to use for the User Application This parameter allows to choose mode of 1st input (IN1). Change it depending on connected device. This parameter allows to choose mode of 2nd input (IN2). Change it depending on connected device. This parameter allows reversing operation of IN1 and IN2 inputs without changing the wiring. Use in case of incorrect wiring. This parameter allows reversing operation of OUT1 and OUT2 inputs without changing the wiring. Use in case of incorrect wiring. This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 20 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter defines which actions result in sending scene ID and attribute assigned to them. Parameter is relevant only if parameter 21 is set to 2 or 3. bitmask. 0 => No scenes sent. 1 => Key pressed 1 time. 2 => Key pressed 2 times. 4 => Key pressed 3 times. 8 => Key hold down and key released. This parameter defines value sent to devices in 2nd association group when IN1 input is triggered (using Basic Command Class). Available settings: 0-255. Default setting: 255. This parameter defines value sent to devices in 2nd association group when IN1 input is deactivated (using Basic Command Class). Available settings: 0-255. Default setting: 255. This parameter defines value sent to devices in 3rd association group when IN2 input is triggered (using Basic Command Class). Available settings: 0-255. Default setting: 255. This parameter defines value sent to devices in 3rd association group when IN2 input is deactivated (using Basic Command Class). Available settings: 0-255. Default setting: 255. This parameter defines minimal change (from the last reported) of analog input value that results in sending new report. Parameter is relevant only for analog inputs (parameter 20 or 21 set to 4 or 5). Available settings: 0 - (reporting on change disabled). 1-100 (0.1-10V, 0.1V step). Default setting: 5 (0.5V). This parameter defines reporting period of analog inputs value. Periodical reports are independent from changes in value (parameter 63). Parameter is relevant only for analog inputs (parameter 20 or 21 set to 4 or 5). Available settings: 0 (periodical reports disabled). 60-32400 (60s-9h). Default setting: 0 (periodical reports disabled). This parameter defines minimal change (from the last reported) of internal temperature sensor value that results in sending new report. Available settings: 0 - (reporting on change disabled). 1-255 (0.1-25.5C). Default setting: 5 (0.5C). This parameter defines reporting period of internal temperature sensor value. Periodical reports are independent from changes in value (parameter 65). Available settings: 0 (periodical reports disabled). 60-32400 (60s-9h). Default setting: 0 (periodical reports disabled). This parameter defines minimal change (from the last reported) of external sensors values (DS18B20 or DHT22) that results in sending new report. Parameter is relevant only for connected DS18B20 or DHT22 sensors. Available settings: 0 - (reporting on change disabled). 1-255 (0.1-25.5 units). Default setting: 5 (0.5 units) This parameter defines reporting period of analog inputs value. Periodical reports are independent from changes in value (parameter 67). Parameter is relevant only for connected DS18B20 or DHT22 sensors. Available settings: 0 - (periodical reports disabled). 60-32400 (60s-9h). Default setting: 0 (periodical reports disabled). This parameter defines the inertia time of IN1 input in alarm modes. Adjust this parameter to prevent bouncing or signal disruptions. Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). Available settings: 1-100 (10ms-1000ms, 10ms step). Default setting: 10 (100ms). This parameter defines the inertia time of IN2 input in alarm modes. Adjust this parameter to prevent bouncing or signal disruptions. Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). Available settings: 1-100 (10ms-1000ms, 10ms step). Default setting: 10 (100ms). This parameter defines additional delay of cancelling the alarm on IN1 input. Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). Available settings: 0 - no delay. 1-3600s. Default setting: 0 (no delay). This parameter defines additional delay of cancelling the alarm on IN2 input. Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). Available settings: 0 - no delay. 1-3600s. Default setting: 0 (no delay). This parameter defines logic of OUT1 output operation. This parameter defines logic of OUT2 output operation. This parameter defines time after which OUT1 will be automatically deactivated. Available settings: 0 - auto off disabled. 1-27000 (0.1s-45min, 0.1s step). Default setting: 0 (auto off disabled). This parameter defines time after which OUT2 will be automatically deactivated. Available settings: 0 - auto off disabled. 1-27000 (0.1s-45min, 0.1s step). Default setting: 0 (auto off disabled). Home Security Alerts Home Security Alerts System Alerts System Alerts System Alerts System Alerts Revision of the Config file currently loaded Revision of the Config file on the File System Latest Revision of the Config file available for download Manufacturer Specific Device ID/Model Device Serial Number Output RF PowerLevel Timeout till the PowerLevel is reset to Normal Apply the Output PowerLevel and Timeout Values Node to Perform a test against PowerLevel to use for the Test How Many Messages to send to the Note for the Test Perform a PowerLevel Test against the a Node Get the results of the latest PowerLevel Test against a Node The Current Status of the last PowerNode Test Executed Number of Messages successfully Acked by the Target Node Protect a device against unintentional control Protect a device against unintentional control Z-Wave Library Version Z-Wave Protocol Version Application Version Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted Is Communication with Device Encrypted