diff --git a/config/shenzen_neo/nas-wr01ze.xml b/config/shenzen_neo/nas-wr01ze.xml new file mode 100644 index 0000000000..08cdec4389 --- /dev/null +++ b/config/shenzen_neo/nas-wr01ze.xml @@ -0,0 +1,89 @@ + + + + + + + + This parameter defined the relay status if remember or not. + If remembered, the plug will restore the relay status last power off when the plug supply power next time. + + + + + + + This parameter defines the button on/off function is enabled or not on the top of the wall plug. + If enabled, users can turn on and off the wall plug by pressing the button on the top of the wall plug. + If disabled, the wall plug cannot be turned on and off by pressing the button. + + + + + + + This parameter defines the LED indication Function ON/OFF. + If disabled, then LED indication Function and will always be turn-off, while enabled means LED Function is on. + + + + + + + This parameter defines the timer function Enable/Disable. + If disabled, then time switch function is not available. + The time period will be defined in parameter #5. + If enabled, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #5 and the plug will turn the relay off. + + + + + + + This parameter defines the time period that plug time switch off. This parameter can be configured 0 - 32767(in minutes). + If Parameter #4 is enabled, and relay is turn-on, the relay will be turn-off after delay this parameter. + + + + + This parameter defines Disable/Enable meter report measure data to controller. + When device is detected an OCP event or the relay turned on or turned off, device still will report all meter values once if this configuration is disabled. + + + + + + This parameter defines interval time (30-32767 seconds) that Meter report data to main controller . + + + + This parameter defines maximum current (in Amperes) the plug can provide to load that be connected to plug. + If the current consumed by load is greater than maximum current, the plug will cut off power, and send NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline. Red Led will blink every seconds until current is normal (less than Parameter #8). + You must remove the loader and turn on the Plug (press the button once) to enable current monitor and clear NOTIFICATION ALARM. This parameter value must be great than #10. + If user set this parameter to default by Configure CC, the parameter #10 will be set to default value. + + + + + This parameter defines by how much power consumed must change to be reported to the Z-Wave Controller or Z-Wave Gateway, in centiAmperes (1-1600). If the rate of power consumed change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z-Wave Controller or Z-Wave Gateway + The changed value = [Value] × 0.01A + + + + + This parameter defines maximum current (in Amperes), if the current plug provide to load is greater than this parameter, the plug will send over-current notification to the controller and the LED will turn RED, but plug cannot cut-off power. This parameter value must be less than parameter #8. + If user set this parameter to default by Configure CC, the parameter #8 will be set to default value. + + + + + + + + + + + +