Description: CPU Custom module for the Inspector
Collect CPU % and report when % over CPU Thresholds which can be configured by changing the values for CPUThreshold in [Inspector].[Settings]
Author: Adrian Buckman
Revision date: 02/01/2020
Credit: David Fowler for the CPU collection query body as this was a snippt taken from a stored procedure he had called sp_CPU_Time
© www.sqlundercover.com
MIT License
------------
Copyright 2019 Sql Undercover
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files
(the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge,
publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so,
subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE
FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION
WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
*********************************************/
SET ANSI_NULLS ON;
SET QUOTED_IDENTIFIER ON;
DECLARE @Revisiondate DATETIME = '20191217';
DECLARE @InspectorBuild DECIMAL(4,2) = (SELECT TRY_CAST([Value] AS DECIMAL(4,2)) FROM [Inspector].[Settings] WHERE [Description] = 'InspectorBuild');
IF SCHEMA_ID(N'Inspector') IS NOT NULL
BEGIN
IF OBJECT_ID('Inspector.CPU',N'U') IS NULL
BEGIN
CREATE TABLE [Inspector].[CPU] (
Servername NVARCHAR(128),
Log_Date DATETIME,
EventTime DATETIME,
SystemCPUUtilization INT,
SQLCPUUtilization INT,
OtherCPU AS SystemCPUUtilization-SQLCPUUtilization
);
END
IF NOT EXISTS(SELECT 1 FROM sys.indexes WHERE [object_id] = OBJECT_ID('Inspector.CPU',N'U') AND [name] = N'CIX_CPU_EventTime')
BEGIN
CREATE CLUSTERED INDEX [CIX_CPU_EventTime] ON [Inspector].[CPU] (EventTime ASC);
END
IF NOT EXISTS(SELECT 1 FROM [Inspector].[Settings] WHERE [Description] = 'CPUHistoryRetentionInDays')
BEGIN
INSERT INTO [Inspector].[Settings] ([Description],[Value])
VALUES('CPUHistoryRetentionInDays','7');
END
IF NOT EXISTS(SELECT 1 FROM [Inspector].[Settings] WHERE [Description] = 'CPUThresholdWarningHighlight')
BEGIN
INSERT INTO [Inspector].[Settings] ([Description],[Value])
VALUES('CPUThresholdWarningHighlight','90');
END
IF NOT EXISTS(SELECT 1 FROM [Inspector].[Settings] WHERE [Description] = 'CPUThresholdAdvisoryHighlight')
BEGIN
INSERT INTO [Inspector].[Settings] ([Description],[Value])
VALUES('CPUThresholdAdvisoryHighlight','85');
END
IF NOT EXISTS(SELECT 1 FROM [Inspector].[Settings] WHERE [Description] = 'CPUThresholdInfoHighlight')
BEGIN
INSERT INTO [Inspector].[Settings] ([Description],[Value])
VALUES('CPUThresholdInfoHighlight','75');
END
IF OBJECT_ID('Inspector.CPUInsert',N'P') IS NULL
BEGIN
EXEC('CREATE PROCEDURE [Inspector].[CPUInsert] AS');
END
IF OBJECT_ID('Inspector.CPUInsert',N'P') IS NOT NULL
BEGIN
EXEC('ALTER PROCEDURE [Inspector].[CPUInsert]
AS
BEGIN
--Revision date: 07/12/2019
DECLARE @ts_now BIGINT
DECLARE @Frequency INT
DECLARE @CPUHistoryRetentionInDays INT
SET @CPUHistoryRetentionInDays = (SELECT ISNULL(TRY_CAST([Value] AS INT),7) FROM [Inspector].[Settings] WHERE [Description] = ''CPUHistoryRetentionInDays'');
SET @Frequency = (SELECT MAX([Frequency]) FROM Inspector.Modules WHERE Modulename = ''CPU'');
SET @ts_now = (SELECT cpu_ticks / (cpu_ticks/ms_ticks) FROM sys.dm_os_sys_info);
IF @CPUHistoryRetentionInDays IS NULL BEGIN SET @CPUHistoryRetentionInDays = 7 END;
DELETE FROM [Inspector].[CPU]
WHERE [EventTime] < DATEADD(DAY,-@CPUHistoryRetentionInDays,GETDATE());
INSERT INTO [Inspector].[CPU] (Servername,Log_Date,EventTime,SystemCPUUtilization,SQLCPUUtilization)
SELECT
@@SERVERNAME,
GETDATE(),
EventTime,
ISNULL(system_cpu_utilization_post_sp2, system_cpu_utilization_pre_sp2) AS SystemCPUUtilization,
ISNULL(sql_cpu_utilization_post_sp2, sql_cpu_utilization_pre_sp2) AS SQLCPUUtilization
FROM
(
SELECT
record.value(''(Record/@id)[1]'', ''int'') AS record_id,
DATEADD (ms, -1 * (@ts_now - [timestamp]), GETDATE()) AS EventTime,
100-record.value(''(Record/SchedulerMonitorEvent/SystemHealth/SystemIdle)[1]'', ''int'') AS system_cpu_utilization_post_sp2,
record.value(''(Record/SchedulerMonitorEvent/SystemHealth/ProcessUtilization)[1]'', ''int'') AS sql_cpu_utilization_post_sp2 ,
100-record.value(''(Record/SchedluerMonitorEvent/SystemHealth/SystemIdle)[1]'', ''int'') AS system_cpu_utilization_pre_sp2,
record.value(''(Record/SchedluerMonitorEvent/SystemHealth/ProcessUtilization)[1]'', ''int'') AS sql_cpu_utilization_pre_sp2
FROM (
SELECT timestamp, CONVERT (xml, record) AS record
FROM sys.dm_os_ring_buffers
WHERE ring_buffer_type = ''RING_BUFFER_SCHEDULER_MONITOR''
AND record LIKE ''%<SystemHealth>%'') AS t
) AS t
WHERE EventTime > DATEADD(MINUTE,-@Frequency,GETDATE())
AND NOT EXISTS (SELECT 1 FROM Inspector.CPU WHERE CPU.EventTime = t.EventTime AND CPU.Servername = @@SERVERNAME);
END');
END
IF OBJECT_ID('Inspector.CPUReport',N'P') IS NULL
BEGIN
EXEC('CREATE PROCEDURE [Inspector].[CPUReport] AS');
END
IF OBJECT_ID('Inspector.CPUReport',N'P') IS NOT NULL
BEGIN
EXEC('ALTER PROCEDURE [Inspector].[CPUReport] (
@Servername NVARCHAR(128),
@Modulename VARCHAR(50),
@TableHeaderColour VARCHAR(7) = ''#E6E6FA'',
@WarningHighlight VARCHAR(7),
@AdvisoryHighlight VARCHAR(7),
@InfoHighlight VARCHAR(7),
@ModuleConfig VARCHAR(20),
@WarningLevel TINYINT,
@ServerSpecific BIT,
@NoClutter BIT,
@TableTail VARCHAR(256),
@HtmlOutput VARCHAR(MAX) OUTPUT,
@CollectionOutOfDate BIT OUTPUT,
@PSCollection BIT,
@Debug BIT = 0
)
AS
--Revision date: 02/01/2020
BEGIN
--Excluded from Warning level control
DECLARE @HtmlTableHead VARCHAR(4000);
DECLARE @Columnnames VARCHAR(2000);
DECLARE @SQLtext NVARCHAR(4000);
DECLARE @CPUThresholdWarningHighlight INT
DECLARE @CPUThresholdAdvisoryHighlight INT
DECLARE @CPUThresholdInfoHighlight INT
DECLARE @Frequency INT
SET @CPUThresholdWarningHighlight = (SELECT ISNULL(TRY_CAST([Value] AS INT),90) FROM [Inspector].[Settings] WHERE [Description] = ''CPUThresholdWarningHighlight'');
SET @CPUThresholdAdvisoryHighlight = (SELECT ISNULL(TRY_CAST([Value] AS INT),85) FROM [Inspector].[Settings] WHERE [Description] = ''CPUThresholdAdvisoryHighlight'');
SET @CPUThresholdInfoHighlight = (SELECT ISNULL(TRY_CAST([Value] AS INT),75) FROM [Inspector].[Settings] WHERE [Description] = ''CPUThresholdInfoHighlight'');
SET @Frequency = (SELECT [Frequency] FROM Inspector.ModuleConfig WHERE ModuleConfig_Desc = @ModuleConfig);
SET @Debug = [Inspector].[GetDebugFlag](@Debug,@ModuleConfig,@Modulename);
--Set defaults if NULL
IF @CPUThresholdWarningHighlight IS NULL BEGIN SET @CPUThresholdInfoHighlight = 90 END;
IF @CPUThresholdAdvisoryHighlight IS NULL BEGIN SET @CPUThresholdInfoHighlight = 85 END;
IF @CPUThresholdInfoHighlight IS NULL BEGIN SET @CPUThresholdInfoHighlight = 75 END;
/********************************************************/
--Your query MUST have a case statement that determines which colour to highlight rows
--Your query MUST use an INTO clause to populate the temp table so that the column names can be determined for the report
--@bgcolor is used the for table highlighting , Warning,Advisory and Info highlighting colours are determined from
--the ModuleWarningLevel table and your Case expression And/or Where clause will determine which rows get the highlight
--query example:
SELECT
CASE
WHEN SystemCPUUtilization >= @CPUThresholdWarningHighlight THEN @WarningHighlight
WHEN SystemCPUUtilization >= @CPUThresholdAdvisoryHighlight AND SystemCPUUtilization < @CPUThresholdWarningHighlight THEN @AdvisoryHighlight
WHEN SystemCPUUtilization > @CPUThresholdInfoHighlight AND SystemCPUUtilization < @CPUThresholdAdvisoryHighlight THEN @InfoHighlight
END AS [@bgcolor],
Servername,
CONVERT(VARCHAR(21),EventTime,113) AS EventTime,
SystemCPUUtilization,
SQLCPUUtilization,
OtherCPU
INTO #InspectorModuleReport
FROM [Inspector].[CPU]
WHERE SystemCPUUtilization > @CPUThresholdInfoHighlight
AND EventTime > DATEADD(HOUR,-@Frequency,GETDATE())
AND Servername = @Servername
ORDER BY EventTime ASC
/********************************************************/
SET @Columnnames = (
SELECT
STUFF(Columnnames,1,1,'''')
FROM
(
SELECT '',''+name
FROM tempdb.sys.all_columns
WHERE [object_id] = OBJECT_ID(N''tempdb.dbo.#InspectorModuleReport'')
AND name != N''@bgcolor''
ORDER BY column_id ASC
FOR XML PATH('''')
) as g (Columnnames)
);
--Set columns names for the Html table
SET @HtmlTableHead = (SELECT [Inspector].[GenerateHtmlTableheader] (
@Servername,
@Modulename,
@ServerSpecific,
''CPU greater than ''+CAST(@CPUThresholdInfoHighlight AS VARCHAR(3))+''%'', --Title for the HTML table, you can use a string here instead such as ''My table title here'' if you want to
@TableHeaderColour,
@Columnnames)
);
SET @SQLtext = N''
SELECT @HtmlOutput =
(SELECT ''
+''[@bgcolor],''
+REPLACE(@Columnnames,'','','' AS ''''td'''','''''''',+ '') + '' AS ''''td'''',''''''''''
+'' FROM #InspectorModuleReport
FOR XML PATH(''''tr''''),Elements);''
--Add an ORDER BY if required
EXEC sp_executesql @SQLtext,N''@HtmlOutput VARCHAR(MAX) OUTPUT'',@HtmlOutput = @HtmlOutput OUTPUT;
--Optional
--If in the above query you populate the table with something like ''No issues present'' then you probably do not want that to
--show when @Noclutter mode is on
IF (@NoClutter = 1)
BEGIN
IF(@HtmlOutput LIKE ''%<Your No issues present text here>%'')
BEGIN
SET @HtmlOutput = NULL;
END
END
--If there is data for the HTML table then build the HTML table
IF (@HtmlOutput IS NOT NULL)
BEGIN
SET @HtmlOutput =
@HtmlTableHead
+ @HtmlOutput
+ @TableTail
+''<p><BR><p>'';
END
IF (@Debug = 1)
BEGIN
SELECT
OBJECT_NAME(@@PROCID) AS ''Procname'',
@Servername AS ''@Servername'',
@Modulename AS ''@Modulename'',
@TableHeaderColour AS ''@TableHeaderColour'',
@WarningHighlight AS ''@WarningHighlight'',
@AdvisoryHighlight AS ''@AdvisoryHighlight'',
@InfoHighlight AS ''@InfoHighlight'',
@ModuleConfig AS ''@ModuleConfig'',
@WarningLevel AS ''@WarningLevel'',
@NoClutter AS ''@NoClutter'',
@TableTail AS ''@TableTail'',
@HtmlOutput AS ''@HtmlOutput'',
@HtmlTableHead AS ''@HtmlTableHead'',
@SQLtext AS ''@SQLtext'',
@CollectionOutOfDate AS ''@CollectionOutOfDate'',
@PSCollection AS ''@PSCollection''
END
END')
END
IF NOT EXISTS(SELECT 1 FROM [Inspector].[Modules] WHERE [Modulename] = 'CPU')
BEGIN
INSERT INTO [Inspector].[Modules] ([ModuleConfig_Desc], [Modulename], [CollectionProcedurename], [ReportProcedurename], [ReportOrder], [WarningLevel], [ServerSpecific], [Debug], [IsActive], [HeaderText], [Frequency], [StartTime], [EndTime])
VALUES('Default','CPU','CPUInsert','CPUReport',5,2,1,0,1,'CPU has exceeded your threshold',2,'00:00','23:59');
END
IF NOT EXISTS(SELECT 1 FROM [Inspector].[MultiWarningModules] WHERE [Modulename] IN ('CPU'))
BEGIN
INSERT INTO [Inspector].[MultiWarningModules] ([Modulename])
VALUES('CPU');
END
IF NOT EXISTS(SELECT 1 FROM sys.columns WHERE [object_id] = OBJECT_ID(N'Inspector.InspectorUpgradeHistory') AND name = 'RevisionDate')
BEGIN
ALTER TABLE [Inspector].[InspectorUpgradeHistory] ADD RevisionDate DATE NULL;
END
EXEC sp_executesql N'
INSERT INTO [Inspector].[InspectorUpgradeHistory] ([Log_Date], [PreserveData], [CurrentBuild], [TargetBuild], [SetupCommand], [RevisionDate])
VALUES(GETDATE(),1,@InspectorBuild,@InspectorBuild,''Inspector_CPU_CustomModule.sql'',@Revisiondate);',
N'@InspectorBuild DECIMAL(4,2),
@Revisiondate DATE',
@InspectorBuild = @InspectorBuild,
@Revisiondate = @Revisiondate;
END
ELSE
BEGIN
RAISERROR('Inspector schema not found, ensure that the Inspector is installed then try running this script again',11,0);
END
/*
SELECT
CASE
WHEN SystemCPUUtilization >= 90 THEN 'RED'
WHEN SystemCPUUtilization > 80 AND SystemCPUUtilization < 90 THEN 'YELLOW'
WHEN SystemCPUUtilization > 75 AND SystemCPUUtilization < 80 THEN 'WHITE'
END AS [@BGColor],
Servername,
CONVERT(VARCHAR(21),EventTime,113) AS EventTime,
SystemCPUUtilization,
SQLCPUUtilization,
OtherCPU
FROM [Inspector].[CPU]
WHERE SystemCPUUtilization > 75
ORDER BY EventTime ASC
*/