SB scale-out: with invalid format SB connection string, request for signalr/hubs pending forever #2628

Closed
Xiaohongt opened this Issue Oct 14, 2013 · 1 comment

2 participants

@Xiaohongt
SignalR member

Functional impact:
With invalid format SB connection string, request for signalr/hubs pending forever, the page including reference signalr/hubs request hang forever.

Repro:
1). in release 1.1.5 branch Asp.Net sample, ConfigureSignalR.cs change to use ServiceBus scale-out with invalid connection string

string SBConnectionString = "Endpoint1=sb://test.servicebus.windows.net/;SharedSecretIssuer=owner;SharedSecretValue=jZsPBWuB85GY4KW9AT7fWUlX1SLn/fhD7py9QUm9i21=";
dependencyResolver.UseServiceBus(SBConnectionString, "Samples");

2). request Hubs/HubConnectionAPI/Default.aspx

Actual results:
the page hang forever, F12 or fiddler we can see that signalr/hubs request pending forever

Expected results:
signalr/hubs request returns 200 like SqlServer in this case, then signalr/connection return the error

#2602

@abnanda1 abnanda1 was assigned Oct 14, 2013
@Xiaohongt Xiaohongt was assigned Oct 16, 2013
@Xiaohongt
SignalR member

verified that signalr/hubs not pending forever in this case

@Xiaohongt Xiaohongt closed this Oct 18, 2013
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment