Branch: master
Find file History
Fetching latest commit…
Cannot retrieve the latest commit at this time.
Permalink
Type Name Latest commit message Commit time
..
Failed to load latest commit information.
images
README.md
bluponix-space-v2.2_ultimate-feeder.ino.ino

README.md

Default Software for BluPonix SPACE v2.2 Ultimate Feeder Personal Cultivation Systems

This is the repository for the default software that ships with any Bluponix Space v2.2 IO board + Arduino Uno hardware ultimate feeder subassembly or hobby starter kit for personal cultivation.

Technical details and more information specific the Space v2.2 IO hardware platform can be found here

  • watering cycles start at moisture level 4 (of 10) & repeats until moisture level reaches 7

  • both 12V DC pump channels switch on in parallel to water from reservoir

4 Operating Modes - Set using jumpers/wires:

Mode 1:  Temperature Sensed Fan Control (or alert) + Small Reservoir Refill (or alert)

- Water Level Sensor Switch triggers Relay 1 for 30s on water low (reservoir refill / light alert)

- Reservoir Temperature Sensor triggers Relay 2 for 60s at 75ºF (start fan control / light alert)

jumper wire connectors shown in red ________________________________________________________________________________________________________________________________

Mode 2:  Temperature Sensed Fan Control (or alert) + Medium Reservoir Refill (or alert)

- Water Level Sensor Switch triggers Relay 1 for 90s on water low (reservoir refill / light alert)

- Reservoir Temperature Sensor triggers Relay 2 for 60s at 72ºF (start fan control / light alert)

jumper wire connections shown in red ________________________________________________________________________________________________________________________________

Mode 3:  Vegetative Lighting (18 hrs light / day) + Temperature Sensed Fan Control (or alert)

- Relay 1 cycles 18 hours on / 4 hours off for lighting control (up to 15A @ 120VAC)

- Reservoir Temperature Sensor triggers Relay 2 for 60s at 75ºF (start fan control / light alert)

jumper wire connections shown in red _________________________________________________________________________________________________________________________________

Mode 4:  Flowering Lighting (12 hrs on / 12 off) + Temperature Sensed Fan Control (or alert)

- Relay 1 cycles 12 hours on / 12 hours off for lighting control (up to 15A @ 120VAC)

- Reservoir Temperature Sensor triggers Relay 2 for 60s at 75ºF (start fan control / light alert)

jumper wire connections shown in red ___________________________________________________________________________________________________________________________________