1.2.6 - Filament Settings Revert #2612

Closed
quillford opened this Issue Feb 1, 2015 · 3 comments

Projects

None yet

3 participants

@quillford

The temperature settings under the Filament Settings tab will revert to their previous value if one manually enters a value. Using the increase/decrease arrows will save changes, however.

OS: OS X 10.10.2
slic3r
slic3r_and_new_issue_ _alexrj_slic3r
version 1.2.6

@alexrj alexrj added this to the 1.2.7 milestone Feb 2, 2015
@gege2b
Contributor
gege2b commented Feb 2, 2015

works fine on win7 x64

@alexrj alexrj added the OS: OSX label Feb 15, 2015
@alexrj
Owner
alexrj commented Feb 22, 2015

Ouch, that's true. It's caused by some behavior change in wxCocoa. I usually develop on a machine that has wxCarbon installed so this didn't happen...

@alexrj alexrj added a commit that referenced this issue May 24, 2015
@alexrj Workaround for wxCocoa bug causing wxSpinCtrl values to be reset when…
… losing focus after changing them from the text field. #2612
8cbb12a
@alexrj
Owner
alexrj commented May 24, 2015

Fixed. Thank you for the report...

@alexrj alexrj closed this May 24, 2015
@alexrj alexrj added the Fixed label May 24, 2015
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment