Other layers temperature not handled correctly with complete individual enabled #2702

Closed
sorki opened this Issue Mar 2, 2015 · 2 comments

Projects

None yet

3 participants

@sorki
sorki commented Mar 2, 2015

Other layers temperature is set only for the first object.

Slic3r 1.2.6

$ grep temperature v4x_20mm-box_kossel.gcode 
M104 S205 ; set temperature
M109 S205 ; wait for temperature to be reached
M104 S215 ; set temperature
M104 S205 ; set temperature
M104 S205 ; set temperature
M104 S205 ; set temperature
; bed_temperature = 0
; first_layer_bed_temperature = 0
; first_layer_temperature = 205
; standby_temperature_delta = -5
; temperature = 215
@alexrj alexrj added this to the 1.2.7 milestone Mar 2, 2015
@alexrj alexrj added a commit that referenced this issue Mar 2, 2015
@alexrj Bugfix: temperature was not set correctly when using sequential print…
…ing. Includes regression test. #2702
a3b843b
@alexrj alexrj added the Fixed label Mar 2, 2015
@alexrj
Owner
alexrj commented Mar 2, 2015

Good catch. I fixed this and added a regression test.

@alexrj alexrj closed this Mar 2, 2015
@lordofhyphens
Collaborator

This might have been around since 1.1.7: #2727

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment