If the stream is null, retrieves the file path from the data sources.
Outputs
Configurations
Scripting
result: beam axial stress (LSDyna)
Description
Read Beam Axial Stress (LSDyna) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
elements scoping required in output.
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5291,7 +5291,7 @@
Configurating operators
Warning: There are multiple results named "current density".
This operator returns the elemental "Source current density", also named "JS" in MAPDL and Mechanical.
To retrieve the result named "current density" in Mechanical or "JC" in MAPDL, use the solver specific operator: mapdl::rth::JC.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5304,7 +5304,7 @@
Configurating operators
Inputs
Outputs
Configurations
Scripting
utility: merge result infos
Description
Assembles a set of result information into a unique one.
Inputs
A vector of result info containers to merge or result infos from pin 0 to ...
Outputs
Configurations
Scripting
result: global total mass (LSDyna)
Description
Read Global Total Mass (LSDyna) by calling the readers defined by the datasources.
-
Inputs
result file container allowed to be kept open to cache data
+
Supported file types
Inputs
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
Unit System ID (int), semicolon-separated list of base unit strings (str) or UnitSystem instance
Outputs
Configurations
Scripting
math: unit convert
Description
Converts an input field/fields container or mesh of a given unit to another unit.
@@ -5320,7 +5320,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: accumulate min over label
Description
Compute the component-wise sum over all the fields that have the same ID as the label set as input in the fields container and take its opposite. This computation can be incremental. If the input fields container is connected and the operator is run multiple times, the output field will be on all the connected inputs.
Inputs
Label of the fields container where it should operate.
Outputs
Configurations
Scripting
result: y plus (y+)
Description
Read Y Plus (y+) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5333,7 +5333,7 @@
Configurating operators
Outputs
Configurations
Scripting
server: grpc shutdown server
Description
Shutdowns dpf's grpc server
Inputs
dpf streams handling the server
Outputs
Configurations
Scripting
result: magnetic scalar potential
Description
Read/compute Magnetic Scalar Potential by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5390,7 +5390,7 @@
Configurating operators
Inputs
field or fields container with only one field is expected
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: plastic strain principal 1
Description
Read/compute element nodal component plastic strains 1st principal component by calling the readers defined by the datasources and computing its eigen values. The off-diagonal strains are first converted from Voigt notation to the standard strain values.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5416,7 +5416,7 @@
Configurating operators
Default is false. If set to true, output of scale is made dimensionless
Default is 0 use mkl. If set to 1, don't
Outputs
Configurations
Scripting
result: enthalpy
Description
Read Enthalpy by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5425,7 +5425,7 @@
Configurating operators
(for Fluid results only) LabelSpace with combination of zone, phases or species ids
Outputs
Configurations
Scripting
math: ^ (fields container)
Description
Computes element-wise field[i]^p.
Inputs
Outputs
Configurations
Scripting
result: global eroded internal energy (LSDyna)
Description
Read Global Eroded Internal Energy (LSDyna) by calling the readers defined by the datasources.
-
Inputs
result file container allowed to be kept open to cache data
+
Supported file types
Inputs
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
Unit System ID (int), semicolon-separated list of base unit strings (str) or UnitSystem instance
Outputs
Configurations
Scripting
math: scale fields container
Description
Scales a fields container by a constant factor. This factor can be a scalar, a vector a field, a fields container, where each value of the vector represents a scaler per component. Number of the components are corresponding to the input field dimensionality
@@ -5452,7 +5452,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: ^2 (field)
Description
Computes element-wise field[i]^2.
Inputs
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: reaction force Z
Description
Read/compute nodal reaction forces Z component of the vector (3rd component) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5461,7 +5461,7 @@
Configurating operators
prevents from reading the mesh in the result files
if 0 cyclic symmetry is ignored, if 1 cyclic sector is read, if 2 cyclic expansion is done, if 3 cyclic expansion is done and stages are merged (default is 1)
Outputs
Configurations
Scripting
result: velocity Z
Description
Read/compute nodal velocities Z component of the vector (3rd component) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5483,7 +5483,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: cos (fields container)
Description
Computes element-wise cos(field[i]).
Inputs
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: initial coordinates (LSDyna)
Description
Read/compute Initial Coordinates (LSDyna) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5499,7 +5499,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: ^2 (fields container)
Description
Computes element-wise field[i]^2.
Inputs
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: mean static pressure
Description
Read Mean Static Pressure by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5514,7 +5514,7 @@
Configurating operators
Inputs
field or fields container with only one field is expected
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: stress max_shear
Description
Reads/computes element nodal component stresses, average it on nodes (by default) and computes its invariants.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5532,17 +5532,17 @@
Configurating operators
Inputs
field or fields container with only one field is expected
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: euler nodes
Description
Reads a field made of 3 coordinates and 3 Euler angles (6 dofs) by node from the result file.
-
Inputs
if true, then the field will only contain the scoping if any rotation is not zero. (default is false).
+
Supported file types
Inputs
if true, then the field will only contain the scoping if any rotation is not zero. (default is false).
if true, then the field has ncomp=6 with 3 coordinates and 3 Euler angles, else there is only the Euler angles (default is true).
Outputs
Configurations
Scripting
result: beam TR shear stress (LSDyna)
Description
Read Beam TR Shear Stress (LSDyna) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
elements scoping required in output.
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
integration point where the result will be read from. Default value: 0 (first integration point).
Unit System ID (int), semicolon-separated list of base unit strings (str) or UnitSystem instance
Outputs
Configurations
Scripting
result: num surface status changes
Description
Read/compute element total number of contact status changes during substep by calling the readers defined by the datasources. Regarding the requested location and the input mesh scoping, the result location can be Nodal/ElementalNodal/Elemental.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5586,7 +5586,7 @@
Configurating operators
Inputs
field or fields container with only one field is expected
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: global sliding interface energy (LSDyna)
Description
Read Global Sliding Interface Energy (LSDyna) by calling the readers defined by the datasources.
-
Inputs
result file container allowed to be kept open to cache data
+
Supported file types
Inputs
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
Unit System ID (int), semicolon-separated list of base unit strings (str) or UnitSystem instance
Outputs
Configurations
Scripting
math: modulus (fields container)
Description
Computes amplitude of a real and an imaginary field.
@@ -5602,7 +5602,7 @@
Configurating operators
if true the field is rotated to global coordinate system (default true). Please check your results carefully if 'false' is used for Elemental or ElementalNodal results averaged to the Nodes when adjacent elements do not share the same coordinate system, as results may be incorrect.
prevents from reading the mesh in the result files
Outputs
Configurations
Scripting
result: gasket stress XZ
Description
Read/compute elemental gasket stress XZ shear component (02 component) by calling the readers defined by the datasources. Regarding the requested location and the input mesh scoping, the result location can be Nodal/ElementalNodal/Elemental.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5619,7 +5619,7 @@
Configurating operators
Inputs
Subpath of the Dpf server. Supported values: 0 (default): root of the server, 1: "dpf/bin/platform", 2: "aisol/bin(dll)/platform", 3: "dpf/plugins", 4: "dpf/workflows".
Outputs
Path to the requested folder in the Dpf server
Configurations
Scripting
result: beam axial force (LSDyna)
Description
Read Beam Axial Force (LSDyna) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
elements scoping required in output.
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5643,7 +5643,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: phase (fields container)
Description
Computes phase (in rad) between real and imaginary fields.
Inputs
Outputs
Configurations
Scripting
math: modulus (field)
Description
Computes element-wise modulus of field containers containing complex fields.
Inputs
Outputs
Configurations
Scripting
result: elemental mass
Description
Read/compute element mass by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5656,7 +5656,7 @@
Configurating operators
time_scoping
Outputs
Field containing the (weighted) sum for each component in an elementary data
Configurations
Scripting
result: heat flux
Description
Read/compute heat flux by calling the readers defined by the datasources. Regarding the requested location and the input mesh scoping, the result location can be Nodal/ElementalNodal/Elemental.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5672,7 +5672,7 @@
Configurating operators
This pin forces elemental nodal shell and solid results to be split if this pin is set to true. If set to false (default), a specific shell layer is still needed to merge the fields. Merge is possible only if a shell layer is provided.
If the requested_location pin is not connected, and if split_shells pin is set to true, we choose one of the shell layer for shell element. If split_shells pin is set to false (default value) and a specific shell layer is provided, results will be merged on this specific shell layer.
Outputs
Configurations
Scripting
result: co-energy
Description
Read/compute co-energy (magnetics) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5693,7 +5693,7 @@
Configurating operators
Outputs
Ids of entities where reference value is zero.
Ids of entities where there are no reference value.
Configurations
Scripting
result: reaction force Y
Description
Read/compute nodal reaction forces Y component of the vector (2nd component) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5702,7 +5702,7 @@
Configurating operators
prevents from reading the mesh in the result files
if 0 cyclic symmetry is ignored, if 1 cyclic sector is read, if 2 cyclic expansion is done, if 3 cyclic expansion is done and stages are merged (default is 1)
Outputs
Configurations
Scripting
result: velocity Y
Description
Read/compute nodal velocities Y component of the vector (2nd component) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5711,11 +5711,11 @@
Configurating operators
prevents from reading the mesh in the result files
if 0 cyclic symmetry is ignored, if 1 cyclic sector is read, if 2 cyclic expansion is done, if 3 cyclic expansion is done and stages are merged (default is 1)
Outputs
Configurations
Scripting
result: global velocity (LSDyna)
Description
Read Global Velocity (LSDyna) by calling the readers defined by the datasources.
-
Inputs
result file container allowed to be kept open to cache data
+
Supported file types
Inputs
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
Unit System ID (int), semicolon-separated list of base unit strings (str) or UnitSystem instance
Outputs
Configurations
Scripting
result: superficial velocity
Description
Read Superficial Velocity by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5725,7 +5725,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: absolute value by component (field)
Description
Compute the absolute value of each data value of the input field, no norm performed.
Inputs
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: thermal strain
Description
Read/compute element nodal component thermal strains by calling the readers defined by the datasources. Regarding the requested location and the input mesh scoping, the result location can be Nodal/ElementalNodal/Elemental.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5737,7 +5737,7 @@
Configurating operators
This pin forces elemental nodal shell and solid results to be split if this pin is set to true. If set to false (default), a specific shell layer is still needed to merge the fields. Merge is possible only if a shell layer is provided.
If the requested_location pin is not connected, and if split_shells pin is set to true, we choose one of the shell layer for shell element. If split_shells pin is set to false (default value) and a specific shell layer is provided, results will be merged on this specific shell layer.
Outputs
Configurations
Scripting
result: incremental energy
Description
Read/compute incremental energy (magnetics) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5747,7 +5747,7 @@
Configurating operators
Outputs
Configurations
Scripting
math: absolute value by component (fields container)
Description
Compute the absolute value of each data value of the input field, no norm performed.
Inputs
field or fields container with only one field is expected
Outputs
Configurations
Scripting
result: stiffness matrix energy
Description
Read/compute element energy associated with the stiffness matrix by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5759,7 +5759,7 @@
Configurating operators
sectors to expand (start at 0), for multistage: use scopings container with 'stage' label, use if cyclic expansion is to be done.
angle phi in degrees (default value 0.0), use if cyclic expansion is to be done.
Outputs
Configurations
Scripting
result: total temperature
Description
Read Total Temperature by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5767,14 +5767,14 @@
Configurating operators
region id (integer) or vector of region ids (vector) or region scoping (scoping) of the model (region corresponds to zone for Fluid results or part for LSDyna results).
(for Fluid results only) LabelSpace with combination of zone, phases or species ids
Outputs
Configurations
Scripting
metadata: element types provider
Description
Reads element types data from the result files contained in the streams or data sources.
-
Inputs
Element Type ids to recover used by the solver. If not set, all available element types to be recovered.
+
Supported file types
Inputs
Element Type ids to recover used by the solver. If not set, all available element types to be recovered.
Result file container allowed to be kept open to cache data.
Result file path container, used if no streams are set.
Outputs
The generic_data_container has a class_name: ElementTypesProperties. It contains the following property fields: element_routine_number: Element routine number. E.g 186 for SOLID186, keyopts: Element type option keys, kdofs: DOF/node for this element type.This is a bit mapping, nodelm: Number of nodes for this element type, nodfor: Number of nodes per element having nodal forces, nodstr: Number of nodes per element having nodal stresses, new_gen_element: Element of new generation.
Configurations
Scripting
utility: delegate to operator
Description
Delegate the run to an Operator instantiated by the name in input (forwards all the input of this Operator to the sub Operator).
Inputs
Outputs
inputs
Configurations
Scripting
result: acceleration Y
Description
Read/compute nodal accelerations Y component of the vector (2nd component) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5793,7 +5793,7 @@
Configurating operators
If element scoping is requested on a nodal named selection, if inclusive == 1 then all the elements/faces adjacent to the nodes/faces ids in input are added, if inclusive == 0, only the elements/faces which have all their nodes/faces in the scoping are included
Outputs
Scoping
Configurations
Scripting
result: stress intensity
Description
Reads/computes element nodal component stresses, average it on nodes (by default) and computes its invariants.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5833,7 +5833,7 @@
Configurating operators
Inputs
If a meshes container is set in input, it is passed on as an output with the additional label space (if any).
Sets a label space.
Outputs
Configurations
Scripting
result: equivalent stress parameter
Description
Read/compute element nodal equivalent stress parameter by calling the readers defined by the datasources. Regarding the requested location and the input mesh scoping, the result location can be Nodal/ElementalNodal/Elemental.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5845,7 +5845,7 @@
Configurating operators
This pin forces elemental nodal shell and solid results to be split if this pin is set to true. If set to false (default), a specific shell layer is still needed to merge the fields. Merge is possible only if a shell layer is provided.
If the requested_location pin is not connected, and if split_shells pin is set to true, we choose one of the shell layer for shell element. If split_shells pin is set to false (default value) and a specific shell layer is provided, results will be merged on this specific shell layer.
Outputs
Configurations
Scripting
result: beam torsional moment (LSDyna)
Description
Read Beam Torsional Moment (LSDyna) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
elements scoping required in output.
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5858,7 +5858,7 @@
Configurating operators
Number of field components. Default is 1.
Scoping.
Outputs
Configurations
Scripting
result: beam axial total strain (LSDyna)
Description
Read Beam Axial Total strain (LSDyna) by calling the readers defined by the datasources.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
elements scoping required in output.
result file container allowed to be kept open to cache data
result file path container, used if no streams are set
@@ -5882,7 +5882,7 @@
Configurating operators
Inputs
field or fields container with only one field is expected
Outputs
Configurations
Scripting
utility: forward fields container
Description
Returns the input field or fields container.
Inputs
Outputs
Configurations
Scripting
result: electric flux density
Description
Read/compute Electric flux density by calling the readers defined by the datasources. Regarding the requested location and the input mesh scoping, the result location can be Nodal/ElementalNodal/Elemental.
-
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
+
Supported file types
Inputs
time/freq values (use doubles or field), time/freq set ids (use ints or scoping) or time/freq step ids (use scoping with TimeFreq_steps location) required in output. To specify time/freq values at specific load steps, put a Field (and not a list) in input with a scoping located on "TimeFreq_steps". Linear time freq intrapolation is performed if the values are not in the result files and the data at the max time or freq is taken when time/freqs are higher than available time/freqs in result files. To get all data for all time/freq sets, connect an int with value -1.
nodes or elements scoping required in output. The output fields will be scoped on these node or element IDs. To figure out the ordering of the fields data, look at their scoping IDs as they might not be ordered as the input scoping was. The scoping's location indicates whether nodes or elements are asked for. Using scopings container allows you to split the result fields container into domains
result file container allowed to be kept open to cache data
@@ -5894,7 +5894,7 @@
Configurating operators
This pin forces elemental nodal shell and solid results to be split if this pin is set to true. If set to false (default), a specific shell layer is still needed to merge the fields. Merge is possible only if a shell layer is provided.
If the requested_location pin is not connected, and if split_shells pin is set to true, we choose one of the shell layer for shell element. If split_shells pin is set to false (default value) and a specific shell layer is provided, results will be merged on this specific shell layer.
Outputs
Configurations
Scripting
result: plastic strain principal 2