'load object refs and speech methods
#Include SayIt.vb
' import BlueIrisLogin def
#Include Secrets.vb
' Note it is also possible to call URLs directly form Blue Iris to set device values in Homeseer
' As in http://HS#IP:PORT/JSON?user=UserName&pass=Password&request=controldevicebyvalue&ref=RefID%&value=Value
' Though be sure the device you are trying to set the value on is set for control and can accept a value in the range you will be sending.
Dim TRIGGER As String = "trigger"
Dim SHOW As String = "show"
Dim port2 = 8078
Dim port3 = 8076
Dim port4 = 8077
Dim port5 = 8075
Public Sub Main(ByVal parms As String)
hs.WriteLog("Main", "parms:" & parms)
End Sub
' convenience methods for calling camShow(ByVal host As String, ByVal port As integer,ByVal parms As String)
' see camShow
Public Sub Iris2Show(ByVal parms As String)
camShow("Iris2",port2,parms)
End Sub
' see camShow
Public Sub Iris3Show(ByVal parms As String)
camShow("Iris3",port3,parms)
End Sub
' see camShow
Public Sub Iris4Show(ByVal parms As String)
camShow("Iris4",port4,parms)
End Sub
' see camShow
Public Sub Iris5Show(ByVal parms As String)
camShow("Iris5",port5,parms)
End Sub
' Set all consoles back to All cameras
Public Sub consoleClear(ByVal notUsed As String)
callBI("Iris2","All cameras",port2,SHOW)
callBI("Iris3","All cameras",port3,SHOW)
callBI("Iris4","All cameras",port4,SHOW)
callBI("Iris5","All cameras",port5,SHOW)
hs.SetDeviceString(Focusedcam4720Ref,"All consoles cleared",TRUE)
hs.SetDeviceValueByRef(Focusedcam4720Ref, 0, TRUE)
End Sub
' Set console back to All cameras
Public Sub Iris2Clear(ByVal notUsed As String)
callBI("Iris2","All cameras",port2,SHOW)
End Sub
' Set console back to All cameras
Public Sub Iris3Clear(ByVal notUsed As String)
callBI("Iris3","All cameras",port3,SHOW)
End Sub
' Set console back to All cameras
Public Sub Iris4Clear(ByVal notUsed As String)
callBI("Iris4","All cameras",port4,SHOW)
End Sub
' Set console back to All cameras
Public Sub Iris5Clear(ByVal notUsed As String)
callBI("Iris5","All cameras",port5,SHOW)
End Sub
' Triggers an alert on camName And highlights the group / switches main video based on the following
' host = Blue Iris server's name
' port = Blue Iris servr's web API port
' parms = camName,grpName,highlight,switchNow
' where
' camName = the short name of the camera (or group) to trigger
' grpName = the group name of the cameras to bring forward on the console
' highlight = Y means bring group forward even if Windfilter3864Ref = 1. N means bring group forward only if Windfilter3864Ref = 0
' switchNow = Y means switch main video even if Windfilter3864Ref = 1. N means switch main video only if Windfilter3864Ref = 0
' uses (Windfilter3864Ref) a flag for reducing highlighting during storms.
' (CamSwitchInput4606Ref) control for PiP HDMI switch
Public Sub camShow(ByVal host As String, ByVal port As integer,ByVal parms As String)
Dim args() As String = Split(parms, ",")
Dim camName As String = args(0)
Dim grpName As String = args(1)
Dim highlight As String = args(2)
Dim switchNow As String = args(3)
callBI(host,camName,port,TRIGGER)
If hs.DeviceValue(Windfilter3864Ref) = 0 Or (Instr(highlight,"Y") > 0) Then
callBI(host,grpName,port,SHOW)
End If
If hs.DeviceValue(Windfilter3864Ref) = 0 Or (Instr(switchNow,"Y") > 0) Then
If (Instr(host,"Iris2") > 0) Then
' switch video distribution to Blue Iris 2 console (input 2)
hs.SetDeviceValueByRef(CamSwitchInput4606Ref, 2, TRUE)
hs.TimerReset("Iris2_motion_delay")
Else If (Instr(host,"Iris3") > 0) Then
' switch video distribution to Blue Iris 3 console (input 3)
hs.SetDeviceValueByRef(CamSwitchInput4606Ref, 3, TRUE)
hs.TimerReset("Iris3_motion_delay")
Else If (Instr(host,"Iris4") > 0) Then
' switch video distribution to Blue Iris 4 console (input 4)
hs.SetDeviceValueByRef(CamSwitchInput4606Ref, 4, TRUE)
hs.TimerReset("Iris4_motion_delay")
Else If (Instr(host,"Iris5") > 0) Then
' switch video distribution to Blue Iris 4 console (input 4)
hs.SetDeviceValueByRef(CamSwitchInput4606Ref, 5, TRUE)
hs.TimerReset("Iris5_motion_delay")
End If
End If
End Sub
' For other things you can do with the Blue Iris API see https://ipcamtalk.com/threads/blue-iris-urls-for-external-streams.24994/ or the Blue Iris help file.
' host can be a name or and IP address but names must be resolvable (ping host works) or use the IP address of the host instead
' With command of trigger = triggers an alert on a camera on the Blue Iris server
' ctlName is the short cam or group name in the camera's config. Must macth exactly.
'
' With command of show = shows the camera group on the console.
' ctlName is the cam group name (camera names will not work) in the camera's config. Must macth exactly. Toi show all use "All cameras"
' uses (CamSwitchInput4606Ref) control for PiP HDMI switch
' (Focusedcam4720Ref) holds last Highlighting message
Public Sub callBI(ByVal host As String, ByVal ctlName As String, ByVal port As integer, ByVal command As String)
Dim label = "callBI"
Dim page = ""
Try
If (Instr(command,TRIGGER) > 0) Then
hs.WriteLog(label, "http://" & host & ":" & port & "/admin?camera=" & ctlName & "&trigger" & BlueIrisLogin)
' hs.GetURL(IP,URL,TRUE,port)
page = hs.GetURL(host,"/admin?camera=" & ctlName & "&trigger" & BlueIrisLogin,TRUE,port)
' reset timer for host console
hs.TimerReset(host & "_motion_delay")
Else If (Instr(command,SHOW) > 0) Then
'hs.WriteLog(label, "ctlName:" & ctlName & " host:" & host & " switch before:" & hs.DeviceValue(CamSwitchInput4606Ref))
Try
Try
hs.SetDeviceString(Focusedcam4720Ref,"Highlighting " & ctlName & " on " & host,TRUE)
If (Instr(host,"Iris2") > 0) Then
hs.SetDeviceValueByRef(Focusedcam4720Ref, 2, TRUE)
Else If (Instr(host,"Iris3") > 0) Then
hs.SetDeviceValueByRef(Focusedcam4720Ref, 3, TRUE)
Else If (Instr(host,"Iris4") > 0) Then
hs.SetDeviceValueByRef(Focusedcam4720Ref, 4, TRUE)
Else If (Instr(host,"Iris5") > 0) Then
hs.SetDeviceValueByRef(Focusedcam4720Ref, 5, TRUE)
Else
hs.SetDeviceValueByRef(Focusedcam4720Ref, 1, TRUE)
End If
Catch ex As Exception
hs.SetDeviceString(Focusedcam4720Ref,"Focusedcam was not stored",TRUE)
End Try
Catch ex As Exception
hs.WriteLog("callBI", "Focusedcam4720Ref:" & Focusedcam4720Ref & "parm:" & "Highlighting " & ctlName & " on " & host)
End Try
If (Instr(ctlName,"All cameras") > 0) Then
' switch video distribution to main video (input 1)
hs.SetDeviceValueByRef(CamSwitchInput4606Ref, 1, TRUE)
End If
' hs.WriteLog(label, " switch after:" & hs.DeviceValue(CamSwitchInput4606Ref))
hs.WriteLog(label, "http://" & host & ":" & port & "/admin?console=" & ctlName & BlueIrisLogin)
' hs.GetURL(IP,URL,TRUE,port)
page = hs.GetURL(host,"/admin?console=" & ctlName & BlueIrisLogin,TRUE,port)
Else
hs.WriteLog(label, "Unsupported command:" & command)
sayLog( "Unsupported command:" & command)
End If
If (Instr(page,"camera=NULL") > 0) Then
hs.WriteLog(label, "camera " & ctlName & " not found")
sayString("camera " & ctlName & " was not found on " & host)
Else If (Instr(page,"var login_version") > 0) Then
'hs.WriteLog(label, "secure session keys blocking API calls. Turn off.")
sayString("secure session keys blocking API calls on " & host & ". Turn off.")
Else If (Instr(page,"Authorization required") > 0) Then
'hs.WriteLog(label, "Login info is incorrect")
sayString( "Login info is incorrect for " & host)
Else If (Instr(page,"signal=greenprofile=") > 0) Then
' sucessful responses can be
' signal=greenprofile=-1lock=0camera=longName
' signal=greenprofile=1lock=2
hs.WriteLog(label, "" & command & " " & ctlName & " was sucessful")
Else
hs.WriteLog(label, "GetURL returned:" & page)
sayLog( "Failed " & command & " of " & ctlName & " on " & host)
End If
Catch ex As Exception
hs.WriteLog("Error", "Exception in script " & label & ": " & ex.Message & " " & host & ":" & port)
End Try
End Sub