<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export>
<version>5.0</version>
<date>2020-12-10T20:04:45Z</date>
<groups>
<group>
<name>Templates</name>
</group>
</groups>
<templates>
<template>
<template>Power Supply NetEngine SNMP</template>
<name>Power Supply NetEngine SNMP</name>
<groups>
<group>
<name>Templates</name>
</group>
</groups>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<items>
<item>
<name>Corrente Fonte A</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.7.4.0</snmp_oid>
<key>hwEntityPwrCurrent.A</key>
<delay>3m</delay>
<value_type>FLOAT</value_type>
<units>A</units>
<description>Este objeto indica a corrente da energia. Unidade: mA</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<preprocessing>
<step>
<type>MULTIPLIER</type>
<params>0.001</params>
</step>
</preprocessing>
</item>
<item>
<name>Corrente Fonte B</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.7.5.0</snmp_oid>
<key>hwEntityPwrCurrent.B</key>
<delay>3m</delay>
<value_type>FLOAT</value_type>
<units>A</units>
<description>Este objeto indica a corrente da energia. Unidade: mA</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<preprocessing>
<step>
<type>MULTIPLIER</type>
<params>0.001</params>
</step>
</preprocessing>
</item>
<item>
<name>Energia Fonte A</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.5.5.0</snmp_oid>
<key>hwEntityPwrPresent.A</key>
<delay>3m</delay>
<description>Presença de energia na fonte A</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<triggers>
<trigger>
<expression>{last()}=0</expression>
<recovery_mode>RECOVERY_EXPRESSION</recovery_mode>
<recovery_expression>{last()}=1</recovery_expression>
<name>Falha de Energia na Fonte A</name>
<priority>HIGH</priority>
<manual_close>YES</manual_close>
</trigger>
</triggers>
</item>
<item>
<name>Energia Fonte B</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.5.5.0</snmp_oid>
<key>hwEntityPwrPresent.B</key>
<delay>3m</delay>
<description>Presença de energia na fonte B</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<triggers>
<trigger>
<expression>{last()}=0</expression>
<recovery_mode>RECOVERY_EXPRESSION</recovery_mode>
<recovery_expression>{last()}=1</recovery_expression>
<name>Falha de Energia na Fonte B</name>
<priority>HIGH</priority>
<manual_close>YES</manual_close>
</trigger>
</triggers>
</item>
<item>
<name>Estado da Energia Fonte A</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.6.4.0</snmp_oid>
<key>hwEntityPwrState.A</key>
<delay>3m</delay>
<description>Status da energia na fonte A</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
</item>
<item>
<name>Estado da Energia Fonte B</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.6.5.0</snmp_oid>
<key>hwEntityPwrState.B</key>
<delay>3m</delay>
<description>Status da energia na fonte B</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
</item>
<item>
<name>Voltagem Fonte A</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.8.4.0</snmp_oid>
<key>hwEntityPwrVoltage.A</key>
<delay>3m</delay>
<value_type>FLOAT</value_type>
<units>V</units>
<description>Este objeto indica a voltagem da energia. Unidade: mV</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<preprocessing>
<step>
<type>MULTIPLIER</type>
<params>0.001</params>
</step>
</preprocessing>
</item>
<item>
<name>Voltagem Fonte B</name>
<type>SNMP_AGENT</type>
<snmp_oid>1.3.6.1.4.1.2011.5.25.31.1.1.18.1.8.5.0</snmp_oid>
<key>hwEntityPwrVoltage.B</key>
<delay>3m</delay>
<value_type>FLOAT</value_type>
<units>V</units>
<description>Este objeto indica a voltagem da energia. Unidade: mV</description>
<applications>
<application>
<name>Power Supply</name>
</application>
</applications>
<preprocessing>
<step>
<type>MULTIPLIER</type>
<params>0.001</params>
</step>
</preprocessing>
</item>
</items>
</template>
</templates>
</zabbix_export>