Hi,

there is an issue in extend-filesystems script that prohibits the script from extending filesystem on raid devices when using HP Smart Array CCISS driver.

log:

Dec 15 08:39:04 *** systemd[1]: Starting Extend Filesystems...
Dec 15 08:39:04 *** extend-filesystems[563]: blockdev: cannot open /dev/cciss!c0d0p9: No such file or directory
Dec 15 08:39:04 *** systemd[1]: extend-filesystems.service: Main process exited, code=exited, status=1/FAILURE

lsblk:

NAME           MAJ:MIN RM   SIZE RO TYPE MOUNTPOINT
sr0             11:0    1  1024M  0 rom  
cciss!c0d0     104:0    0 279.4G  0 disk 
|-cciss!c0d0p1 104:1    0   128M  0 part /boot
|-cciss!c0d0p2 104:2    0     2M  0 part 
|-cciss!c0d0p3 104:3    0     1G  0 part /usr
|-cciss!c0d0p4 104:4    0     1G  0 part 
|-cciss!c0d0p6 104:6    0   128M  0 part /usr/share/oem
|-cciss!c0d0p7 104:7    0    64M  0 part 
`-cciss!c0d0p9 104:9    0 277.1G  0 part /

Thanks!