diff --git a/doc/src/records/dhwheater-doc.md b/doc/src/records/dhwheater-doc.md index 49993c589..a495085c7 100644 --- a/doc/src/records/dhwheater-doc.md +++ b/doc/src/records/dhwheater-doc.md @@ -352,6 +352,11 @@ Air source heat pump type, valid only if whHeatSrc=ASHPX. These choices are supp "Scalable_SP","single pass scalable type for autosized standard design" "Scalable_MP","multipass scalable type for autosized standard design" "AquaThermAire","Vallara AquaThermAire HPWH" +"GenericUEF217","65-gal tank meeting Federal standard minimum requirement" +"AWHSTier4Generic40","Any 40-gal tank meeting Advanced Water Heating Specification Tier-4 minimum requirements" +"AWHSTier4Generic50","Any 50-gal tank meeting Advanced Water Heating Specification Tier-4 minimum requirements" +"AWHSTier4Generic65","Any 65-gal tank meeting Advanced Water Heating Specification Tier-4 minimum requirements" +"AWHSTier4Generic80","Any 80-gal tank meeting Advanced Water Heating Specification Tier-4 minimum requirements" END %>