clocksource/drivers/timer-ti-dm: Do not update counter on updating the period
Write to trigger register(OMAP_TIMER_TRIGGER_REG) will load the value in Load register(OMAP_TIMER_LOAD_REG) into Counter register (OMAP_TIMER_COUNTER_REG). omap_dm_timer_set_load() writes into trigger register every time load register is updated. When timer is configured in pwm mode, this causes disruption in current pwm cycle, which is not expected especially when pwm is used as PPS signal for synchronized PTP clocks. So do not write into trigger register on updating the period. Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com> Tested-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20200224050753.17784-3-lokeshvutla@ti.com
1 parent ad1ded9 commit 6ce4fcb

File tree

1 file changed

+0
-1
lines changed

1 file changed

+0
-1
lines changed

drivers/clocksource/timer-ti-dm.c

Lines changed: 0 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -577,7 +577,6 @@ static int omap_dm_timer_set_load(struct omap_dm_timer *timer, int autoreload,
577577
omap_dm_timer_write_reg(timer, OMAP_TIMER_CTRL_REG, l);
578578
omap_dm_timer_write_reg(timer, OMAP_TIMER_LOAD_REG, load);
579579

580-
omap_dm_timer_write_reg(timer, OMAP_TIMER_TRIGGER_REG, 0);
581580
/* Save the context */
582581
timer->context.tclr = l;
583582
timer->context.tldr = load;