OpticalThickness.py/compute_tau_H2ON2_CO2dilute #2

Closed
aromanro opened this Issue Sep 27, 2018 · 1 comment

Comments

Projects
None yet
2 participants
@aromanro

aromanro commented Sep 27, 2018

On line 63, in compute_tau_H2ON2_CO2dilute, kappaCO2 = getKappa_HITRAN is called with "H2O". Shouldn't be called with "CO2"?

@ddbkoll

This comment has been minimized.

Owner

ddbkoll commented Sep 30, 2018

That's correct! Fixed now.
Note, there's a number of other issues that should still be fixed, I'll open an issue.

@ddbkoll ddbkoll closed this Sep 30, 2018