* HomeSeer HS-FLS100+ Floodlight Sensor | |
* version: 1.4 | |
*/ | |
import groovy.transform.Field | |
metadata { | |
definition (name: "HomeSeer HS-FLS100+ Floodlight Sensor", namespace: "djdizzyd", author: "Bryan Copeland", importUrl: "https://raw.githubusercontent.com/djdizzyd/hubitat/master/Drivers/HomeSeer/HS-FLS100-Floodlight-Sensor.groovy") { | |
capability "Switch" | |
capability "Refresh" | |
capability "Actuator" | |
capability "Sensor" | |
capability "Configuration" | |
capability "MotionSensor" | |
capability "IlluminanceMeasurement" | |
fingerprint mfr:"000C", prod:"0201", deviceId:"000B", inClusters:"0x5E,0x85,0x59,0x55,0x86,0x72,0x5A,0x73,0x9F,0x6C,0x7A,0x71,0x25,0x31,0x70,0x30", deviceJoinName: "HomeSeer HS-FLS100+" | |
} | |
preferences { | |
configParams.each { input it.value.input } | |
input name: "logEnable", type: "bool", title: "Enable debug logging", defaultValue: true | |
input name: "txtEnable", type: "bool", title: "TXT Descriptive logging", defaultValue: false | |
} | |
} | |
@Field static Map configParams = [ | |
1: [input: [name: "configParam1", type: "number", title: "PIR Trigger Off period", description: "seconds 8-720", defaultValue: 15, range:"8..720"], parameterSize: 2], | |
2: [input: [name: "configParam2", type: "enum", title: "Lux Threshold Settings", description: "", defaultValue: 50, options:[0:"Always don't turn on light",255:"Turn Light on by PIR",30:"Turn light on @ 30 Lux",40:"Turn light on @ 40 lux",50:"Turn light on @ 50 lux", 60:"Turn light on @ 60 lux",70:"Turn light on @ 70 lux",80:"Turn light on @ 80 lux", 90:"Turn light on @ 90 lux", 100:"Turn light on @ 100 lux", 110:"Turn light on @ 110 lux", 120:"Turn light on @ 120 lux", 130:"Turn light on @ 130 lux", 140:"Turn light on @ 140 lux", 150:"Turn light on @ 150 lux", 160:"Turn light on @ 160 lux", 170:"Turn light on @ 170 lux", 180:"Turn light on @ 180 lux", 190:"Turn light on @ 190 lux", 200:"Turn light on @ 200 lux"]], parameterSize: 2], | |
3: [input: [name: "configParam3", type: "number", title: "Lux level report", description: "minutes 0 to 1440 minutes", defaultValue: 10, range:"0..1440"], parameterSize: 2] | |
] | |
@Field static Map ZWAVE_NOTIFICATION_TYPES=[0:"Reserverd", 1:"Smoke", 2:"CO", 3:"CO2", 4:"Heat", 5:"Water", 6:"Access Control", 7:"Home Security", 8:"Power Management", 9:"System", 10:"Emergency", 11:"Clock", 12:"First"] | |
@Field static Map CMD_CLASS_VERS=[0x20:1,0x86:2,0x72:2,0x5B:3,0x70:1,0x85:2,0x59:1,0x31:5,0x71:4] | |
void logsOff(){ | |
log.warn "debug logging disabled..." | |
device.updateSetting("logEnable",[value:"false",type:"bool"]) | |
} | |
void configure() { | |
if (!state.initialized) initializeVars() | |
runIn(5,pollDeviceData) | |
} | |
void initializeVars() { | |
// first run only | |
state.initialized=true | |
runIn(5, refresh) | |
} | |
void updated() { | |
log.info "updated..." | |
log.warn "debug logging is: ${logEnable == true}" | |
unschedule() | |
if (logEnable) runIn(1800,logsOff) | |
List<hubitat.zwave.Command> cmds=[] | |
cmds.addAll(runConfigs()) | |
sendToDevice(cmds) | |
} | |
List<hubitat.zwave.Command> runConfigs() { | |
List<hubitat.zwave.Command> cmds=[] | |
configParams.each { param, data -> | |
if (settings[data.input.name]) { | |
cmds.addAll(configCmd(param, data.parameterSize, settings[data.input.name])) | |
} | |
} | |
return cmds | |
} | |
List<hubitat.zwave.Command> pollConfigs() { | |
List<hubitat.zwave.Command> cmds=[] | |
configParams.each { param, data -> | |
if (settings[data.input.name]) { | |
cmds.add(zwave.configurationV1.configurationGet(parameterNumber: param.toInteger())) | |
} | |
} | |
return cmds | |
} | |
List<hubitat.zwave.Command> configCmd(parameterNumber, size, scaledConfigurationValue) { | |
List<hubitat.zwave.Command> cmds = [] | |
cmds.add(zwave.configurationV1.configurationSet(parameterNumber: parameterNumber.toInteger(), size: size.toInteger(), scaledConfigurationValue: scaledConfigurationValue.toInteger())) | |
cmds.add(zwave.configurationV1.configurationGet(parameterNumber: parameterNumber.toInteger())) | |
return cmds | |
} | |
void zwaveEvent(hubitat.zwave.commands.configurationv1.ConfigurationReport cmd) { | |
if(configParams[cmd.parameterNumber.toInteger()]) { | |
Map configParam=configParams[cmd.parameterNumber.toInteger()] | |
int scaledValue | |
cmd.configurationValue.reverse().eachWithIndex { v, index -> scaledValue=scaledValue | v << (8*index) } | |
device.updateSetting(configParam.input.name, [value: "${scaledValue}", type: configParam.input.type]) | |
} | |
} | |
void pollDeviceData() { | |
List<hubitat.zwave.Command> cmds = [] | |
cmds.add(zwave.versionV2.versionGet()) | |
cmds.add(zwave.manufacturerSpecificV2.deviceSpecificGet(deviceIdType: 1)) | |
cmds.addAll(processAssociations()) | |
cmds.addAll(pollConfigs()) | |
cmds.add(zwave.sensorMultilevelV5.sensorMultilevelGet(scale: 1, sensorType: 3)) | |
cmds.add(zwave.notificationV4.notificationGet(notificationType: 7, event:0)) | |
cmds.add(zwave.switchBinaryV1.switchBinaryGet()) | |
sendToDevice(cmds) | |
} | |
void refresh() { | |
List<hubitat.zwave.Command> cmds=[] | |
cmds.add(zwave.switchBinaryV1.switchBinaryGet()) | |
cmds.add(zwave.sensorMultilevelV5.sensorMultilevelGet(scale: 1, sensorType: 3)) | |
cmds.add(zwave.notificationV4.notificationGet(notificationType: 7, event:0)) | |
sendToDevice(cmds) | |
} | |
void installed() { | |
if (logEnable) log.debug "installed()..." | |
initializeVars() | |
} | |
void eventProcess(Map evt) { | |
if (device.currentValue(evt.name).toString() != evt.value.toString() || !eventFilter) { | |
evt.isStateChange=true | |
sendEvent(evt) | |
} | |
} | |
void zwaveEvent(hubitat.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) { | |
if (logEnable) log.debug "${cmd}" | |
Map evt = [isStateChange:false] | |
switch (cmd.sensorType) { | |
case 3: | |
evt.name = "illuminance" | |
evt.value = cmd.scaledSensorValue.toInteger() | |
evt.unit = "lux" | |
evt.isStateChange=true | |
evt.descriptionText="${device.displayName}: Illuminance report received: ${evt.value}" | |
break | |
} | |
if (evt.isStateChange) { | |
if (txtEnable) log.info evt.descriptionText | |
eventProcess(evt) | |
} | |
} | |
void zwaveEvent(hubitat.zwave.commands.sensorbinaryv1.SensorBinaryReport cmd) { | |
if (logEnable) log.debug "Sensor binary report: ${cmd}" | |
// redundant and un-needed function | |
} | |
void zwaveEvent(hubitat.zwave.commands.notificationv4.NotificationReport cmd) { | |
Map evt = [isStateChange:false] | |
if (logEnable) log.info "Notification: " + ZWAVE_NOTIFICATION_TYPES[cmd.notificationType.toInteger()] | |
if (cmd.notificationType==7) { | |
// home security | |
switch (cmd.event) { | |
case 0: | |
// state idle | |
if (cmd.eventParametersLength > 0) { | |
switch (cmd.eventParameter[0]) { | |
case 7: | |
evt.name = "motion" | |
evt.value = "inactive" | |
evt.isStateChange = true | |
evt.descriptionText = "${device.displayName} motion became ${evt.value}" | |
break | |
case 8: | |
evt.name = "motion" | |
evt.value = "inactive" | |
evt.isStateChange = true | |
evt.descriptionText = "${device.displayName} motion became ${evt.value}" | |
break | |
} | |
} else { | |
evt.name = "motion" | |
evt.value = "inactive" | |
evt.descriptionText = "${device.displayName} motion became ${evt.value}" | |
evt.isStateChange = true | |
} | |
break | |
case 7: | |
// motion detected (location provided) | |
evt.name = "motion" | |
evt.value = "active" | |
evt.isStateChange = true | |
evt.descriptionText = "${device.displayName} motion became ${evt.value}" | |
break | |
case 8: | |
// motion detected | |
evt.name = "motion" | |
evt.value = "active" | |
evt.isStateChange = true | |
evt.descriptionText = "${device.displayName} motion became ${evt.value}" | |
break | |
case 254: | |
// unknown event/state | |
log.warn "Device sent unknown event / state notification" | |
break | |
} | |
} | |
if (evt.isStateChange) { | |
if (txtEnable) log.info evt.descriptionText | |
eventProcess(evt) | |
} | |
} | |
void zwaveEvent(hubitat.zwave.commands.basicv1.BasicReport cmd) { | |
if (logEnable) log.debug cmd | |
switchEvents(cmd) | |
} | |
private void switchEvents(hubitat.zwave.Command cmd) { | |
String value = (cmd.value ? "on" : "off") | |
String description = "${device.displayName} was turned ${value}" | |
if (txtEnable) log.info description | |
eventProcess(name: "switch", value: value, descriptionText: description, type: state.isDigital?"digital":"physical") | |
state.isDigital=false | |
} | |
void zwaveEvent(hubitat.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) { | |
if (logEnable) log.debug cmd | |
switchEvents(cmd) | |
} | |
void on() { | |
state.isDigital=true | |
sendToDevice(zwave.basicV1.basicSet(value: 0xFF)) | |
} | |
void off() { | |
state.isDigital=true | |
sendToDevice(zwave.basicV1.basicSet(value: 0x00)) | |
} | |
void zwaveEvent(hubitat.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) { | |
hubitat.zwave.Command encapsulatedCommand = cmd.encapsulatedCommand(CMD_CLASS_VERS) | |
if (encapsulatedCommand) { | |
zwaveEvent(encapsulatedCommand) | |
} | |
} | |
void parse(String description) { | |
if (logEnable) log.debug "parse:${description}" | |
hubitat.zwave.Command cmd = zwave.parse(description, CMD_CLASS_VERS) | |
if (cmd) { | |
zwaveEvent(cmd) | |
} | |
} | |
void zwaveEvent(hubitat.zwave.commands.supervisionv1.SupervisionGet cmd) { | |
if (logEnable) log.debug "Supervision get: ${cmd}" | |
hubitat.zwave.Command encapsulatedCommand = cmd.encapsulatedCommand(CMD_CLASS_VERS) | |
if (encapsulatedCommand) { | |
zwaveEvent(encapsulatedCommand) | |
} | |
sendToDevice(new hubitat.zwave.commands.supervisionv1.SupervisionReport(sessionID: cmd.sessionID, reserved: 0, moreStatusUpdates: false, status: 0xFF, duration: 0)) | |
} | |
void zwaveEvent(hubitat.zwave.commands.manufacturerspecificv2.DeviceSpecificReport cmd) { | |
if (logEnable) log.debug "Device Specific Report: ${cmd}" | |
switch (cmd.deviceIdType) { | |
case 1: | |
// serial number | |
def serialNumber="" | |
if (cmd.deviceIdDataFormat==1) { | |
cmd.deviceIdData.each { serialNumber += hubitat.helper.HexUtils.integerToHexString(it & 0xff,1).padLeft(2, '0')} | |
} else { | |
cmd.deviceIdData.each { serialNumber += (char) it } | |
} | |
device.updateDataValue("serialNumber", serialNumber) | |
break | |
} | |
} | |
void zwaveEvent(hubitat.zwave.commands.versionv2.VersionReport cmd) { | |
if (logEnable) log.debug "version2 report: ${cmd}" | |
device.updateDataValue("firmwareVersion", "${cmd.firmware0Version}.${cmd.firmware0SubVersion}") | |
device.updateDataValue("protocolVersion", "${cmd.zWaveProtocolVersion}.${cmd.zWaveProtocolSubVersion}") | |
device.updateDataValue("hardwareVersion", "${cmd.hardwareVersion}") | |
} | |
void sendToDevice(List<hubitat.zwave.Command> cmds) { | |
sendHubCommand(new hubitat.device.HubMultiAction(commands(cmds), hubitat.device.Protocol.ZWAVE)) | |
} | |
void sendToDevice(hubitat.zwave.Command cmd) { | |
sendHubCommand(new hubitat.device.HubAction(secureCommand(cmd), hubitat.device.Protocol.ZWAVE)) | |
} | |
void sendToDevice(String cmd) { | |
sendHubCommand(new hubitat.device.HubAction(secureCommand(cmd), hubitat.device.Protocol.ZWAVE)) | |
} | |
List<String> commands(List<hubitat.zwave.Command> cmds, Long delay=300) { | |
return delayBetween(cmds.collect{ secureCommand(it) }, delay) | |
} | |
String secureCommand(hubitat.zwave.Command cmd) { | |
secureCommand(cmd.format()) | |
} | |
String secureCommand(String cmd) { | |
String encap="" | |
if (getDataValue("zwaveSecurePairingComplete") != "true") { | |
return cmd | |
} else { | |
encap = "988100" | |
} | |
return "${encap}${cmd}" | |
} | |
void zwaveEvent(hubitat.zwave.Command cmd) { | |
if (logEnable) log.debug "skip:${cmd}" | |
} | |
List<hubitat.zwave.Command> setDefaultAssociation() { | |
List<hubitat.zwave.Command> cmds=[] | |
cmds.add(zwave.associationV2.associationSet(groupingIdentifier: 1, nodeId: zwaveHubNodeId)) | |
cmds.add(zwave.associationV2.associationGet(groupingIdentifier: 1)) | |
return cmds | |
} | |
List<hubitat.zwave.Command> processAssociations(){ | |
List<hubitat.zwave.Command> cmds = [] | |
cmds.addAll(setDefaultAssociation()) | |
if (logEnable) log.debug "processAssociations cmds: ${cmds}" | |
return cmds | |
} | |
void zwaveEvent(hubitat.zwave.commands.associationv2.AssociationReport cmd) { | |
if (logEnable) log.debug "${device.label?device.label:device.name}: ${cmd}" | |
List<String> temp = [] | |
if (cmd.nodeId != []) { | |
cmd.nodeId.each { | |
temp.add(it.toString().format( '%02x', it.toInteger() ).toUpperCase()) | |
} | |
} | |
updateDataValue("zwaveAssociationG${cmd.groupingIdentifier}", "$temp") | |
} | |
void zwaveEvent(hubitat.zwave.commands.associationv2.AssociationGroupingsReport cmd) { | |
if (logEnable) log.debug "${device.label?device.label:device.name}: ${cmd}" | |
log.info "${device.label?device.label:device.name}: Supported association groups: ${cmd.supportedGroupings}" | |
state.associationGroups = cmd.supportedGroupings | |
} | |