@@ -73,7 +73,7 @@ Product Type ID: EU=0x00, US=0x01, AU=0x02 CN=0x1D
</Help>
</Value>
<Value type="list" index="90" genre="config" label="Enable/disable the parameter 91 and 92" units="" size="1" value="0">
- <Help>If this parameter is set to 1 (Enable), the parameter 101 103 should be set to 0.</Help>
+ <Help>If this parameter is set to 1 (Enable), the parameter 101 - 103 should be set to 0.</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="1" />
</Value>
@@ -0,0 +1,48 @@
+<?xml version="1.0" encoding="utf-8"?>
+<Product xmlns='http://code.google.com/p/open-zwave/'>
+ <!-- Configuration Parameters -->
+ <CommandClass id="112">
+ <Value type="byte" index="1" genre="config" label="Delayed OFF time" units="seconds" min="0" max="255" value="0">
+ <Help>
+ The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
+ </Help>
+ </Value>
+ <Value type="byte" index="2" genre="config" label="Panic ON time" units="seconds" min="1" max="255" value="0">
+ <Help>
+ The amount of time in seconds the switch will turn on for when panic mode is trigered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
+ </Help>
+ </Value>
+ <Value type="byte" index="3" genre="config" label="Panic OFF time" units="seconds" min="1" max="255" value="0">
+ <Help>
+ The amount of time in seconds the switch will turn off for when panic mode is triggered. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
+ </Help>
+ </Value>
+ <Value type="byte" index="4" genre="config" label="Basic set value" units="" min="1" max="255" value="0">
+ <Help>
+ Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation
+ </Help>
+ </Value>
+ <Value type="list" index="5" genre="config" label="Power Up State" units="" min="1" max="3" size="1" value="3">
+ <Help>
+ Power up state of the device
+ </Help>
+ <Item label="OFF" value="1"/>
+ <Item label="ON" value="2"/>
+ <Item label="Last state" value="3"/>
+ </Value>
+ <Value type="list" index="6" genre="config" label="Panic mode enable" units="" min="1" max="2" size="1" value="1">
+ <Help>
+ Enables this switch to participate in panic mode
+ </Help>
+ <Item label="OFF" value="1"/>
+ <Item label="ON" value="2"/>
+ </Value>
+ </CommandClass>
+ <!-- Association Groups -->
+ <CommandClass id="133">
+ <Associations num_groups="2">
+ <Group index="1" max_associations="5" label="Group #1" />
+ <Group index="255" max_associations="1" label="Group #255" />
+ </Associations>
+ </CommandClass>
+</Product>
@@ -0,0 +1,22 @@
+<?xml version="1.0" encoding="utf-8"?>
+<Product xmlns='http://code.google.com/p/open-zwave/'>
+ <!-- Configuration Parameters -->
+ <CommandClass id="112">
+ <Value type="byte" index="1" genre="config" label="Delayed OFF time" units="seconds" min="0" max="255" value="0">
+ <Help>
+ The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
+ </Help>
+ </Value>
+ <Value type="byte" index="4" genre="config" label="Basic set value" units="" min="1" max="255" value="0">
+ <Help>
+ Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation
+ </Help>
+ </Value>
+ </CommandClass>
+ <!-- Association Groups -->
+ <CommandClass id="133">
+ <Associations num_groups="1">
+ <Group index="1" max_associations="5" label="Group #1" />
+ </Associations>
+ </CommandClass>
+</Product>
@@ -0,0 +1,42 @@
+<?xml version="1.0" encoding="utf-8"?>
+<Product xmlns='http://code.google.com/p/open-zwave/'>
+ <!-- Configuration Parameters -->
+ <CommandClass id="112">
+ <Value type="byte" index="1" genre="config" label="Delayed OFF time" units="seconds" min="0" max="255" value="0">
+ <Help>
+ The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
+ </Help>
+ </Value>
+ <Value type="byte" index="4" genre="config" label="Basic set value" units="" min="1" max="255" value="0">
+ <Help>
+ Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation
+ </Help>
+ </Value>
+ <Value type="list" index="5" genre="config" label="Power Up State" units="" min="1" max="3" size="1" value="3">
+ <Help>
+ Power up state of the device
+ </Help>
+ <Item label="OFF" value="1"/>
+ <Item label="ON" value="2"/>
+ <Item label="Last state" value="3"/>
+ </Value>
+ <Value type="list" index="6" genre="config" label="Panic mode enable" units="" min="1" max="2" size="1" value="1">
+ <Help>
+ Enables this switch to participate in panic mode
+ </Help>
+ <Item label="OFF" value="1"/>
+ <Item label="ON" value="2"/>
+ </Value>
+ <Value type="byte" index="7" genre="config" label="Dimmer Ramp Time" units="seconds" min="0" max="255" value="0">
+ <Help>
+ The amount of time in seconds the switch will take to reach the desired dim level. The configuration value is a signed single byte number. This value may represent a value with no units or may represent a value such as time. 0 to 127 (decimal) represents 0 to 127 seconds of time. -128 to -1 (negative decimal numbers) represents 128 to 255 seconds as calculated by this formula. Config value = desired time in seconds (or desired value) -256 For an example of 172 seconds: config value = 172 - 256 = -84 (decimal) or 0xAC (hex)
+ </Help>
+ </Value>
+ </CommandClass>
+ <!-- Association Groups -->
+ <CommandClass id="133">
+ <Associations num_groups="1">
+ <Group index="1" max_associations="5" label="Group #1" />
+ </Associations>
+ </CommandClass>
+</Product>
@@ -27,7 +27,7 @@ http://www.pepper1.net/zwavedb/device/911
</Value>
<Value type="list" index="5" genre="config" label="Restore switch state mode" min="0" max="2" value="1" units="" size="1">
<Help>
- Whenever the AC power return from lost, Home Control Metering Plug will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
+ Whenever the AC power return from lost, Home Control Metering Plug will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE.
</Help>
<Item label="Switch off" value="0" />
<Item label="Last switch state" value="1" />
@@ -44,7 +44,7 @@ http://www.pepper1.net/zwavedb/device/911
<Help>
LED indication mode
</Help>
- <Item label="Show Switch StateWhen switch is on, LED is on. When switch is off, LED is off." value="1" />
+ <Item label="Show Switch State:When switch is on, LED is on. When switch is off, LED is off." value="1" />
<Item label="When switch is on, LED is off. When switch is off, LED is on." value="2" />
<Item label="When the state of switch changes, LED will be on only one second, then LED keeps off." value="3" />
</Value>
@@ -55,7 +55,7 @@ http://www.pepper1.net/zwavedb/device/911
</Value>
<Value type="list" index="9" genre="config" label="RF off command mode" min="0" max="3" value="0" units="" size="1">
<Help>
- Whenever a switch off command,BASIC_SET BINARY_SWITCH_SET SWITCH_ALL_OFF, is received, it could be interpreted as a variety of 4 commands.
+ Whenever a switch off command,BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as a variety of 4 commands.
</Help>
<Item label="It switches to OFF state." value="0" />
<Item label="The switch off command will be ignored." value="1" />
@@ -37,7 +37,7 @@
<Help>
1 : go to comfortable position.
[2 to 99] select comfortable position.
- 32 default
+ 32 - default
</Help>
</Value>
@@ -37,7 +37,7 @@
<Help>
1 : go to comfortable position.
[2 to 99] select comfortable position.
- 32 default
+ 32 - default
</Help>
</Value>
@@ -54,7 +54,7 @@
Possible parameter settings:-10000 to 10000 [each 0.01oC] [-100oC to 100oC].</Help>
</Value>
<Value type="list" genre="config" instance="1" index="74" label="Alarm frame sent to 1st and 4th Association Group activation." value="2" size="1">
- <Help>The device is able to report tamper alarms resulting from sensor’s tilt/movement or TMP button state change.</Help>
+ <Help>The device is able to report tamper alarms resulting from sensor tilt/movement or TMP button state change.</Help>
<Item label="Tamper alarms INACTIVE" value="0" />
<Item label="Button tamper alarm ACTIVE" value="1" />
<Item label="Movement tamper alarm ACTIVE" value="2" />
@@ -98,7 +98,7 @@
<Value type="short" genre="config" instance="1" index="51" label="Temperature reports threshold" value="10" min="0" max="300" size="2">
<Help>This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller.
0 - temperature reports based on threshold disabled
- 1-300 - temperature threshold (0.1-30°C, 0.1°C step)
+ 1-300 - temperature threshold (0.1-30C, 0.1C step)
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="52" label="Interval of temperature reports" value="0" min="0" max="32400" size="2" units="seconds">
@@ -108,7 +108,7 @@
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="53" label="Temperature offset" value="0" min="-1000" max="1000" size="4">
- <Help>The value to be added to the actual temperature, measured by the sensor (temperature compensation). (0,1°C steps)
+ <Help>The value to be added to the actual temperature, measured by the sensor (temperature compensation). (0,1C steps)
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="54" label="Temperature alarm reports" value="0" size="1">
@@ -121,12 +121,12 @@
</Value>
<Value type="short" genre="config" instance="1" index="55" label="High temperature alarm threshold" value="540" min="0" max="1000" size="2">
<Help>If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated).
- 0-1000 (0-100°C, 0.1°C step).
+ 0-1000 (0-100C, 0.1C step).
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="56" label="Low temperature alarm threshold" value="40" min="-300" max="700" size="2">
<Help>If temperature is lower than the set value, underheat notification will be sent and low temperature scene will be triggered (if activated).
- 300-700 (-30-70°C, 0.1°C step)
+ 300-700 (-30-70C, 0.1C step)
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="70" label="Scene activation functionality" value="0" min="0" max="3903" size="2">
@@ -159,10 +159,10 @@
<Help>This parameter defines how commands are sent in specified association groups: as secure or non-secure.
Parameter is active only in Z-Wave network security mode. It does not apply to 1st group Lifeline
0 - none of the groups sent as secure.
- 1 - 2nd group Control sent as secure.
- 2 - 3rd group Alarm sent as secure.
- 4 - 4th group Sensor ZW3 sent as secure.
- 8 - 5th group Tamper ZW3 sent as secure.
+ 1 - 2nd group Control sent as secure.
+ 2 - 3rd group Alarm sent as secure.
+ 4 - 4th group Sensor ZW3 sent as secure.
+ 8 - 5th group Tamper ZW3 sent as secure.
</Help>
</Value>
</CommandClass>
@@ -1,7 +1,10 @@
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
-
+ <!--
+ Fibaro Motion Sensor FGMS-001
+ http://www.fibaro.com/manuals/en/Motion-Sensor/Motion-Sensor_EN_5.3.14.pdf
+ -->
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Motion sensor's sensitivity" min="0" max="255" value="10">
@@ -161,7 +164,7 @@
<Item label="Tamper + Cancellation + Orientation" value="3" />
<Item label="Vibration" value="4" />
</Value>
- <Value type="byte" genre="config" instance="1" index="26" label="Tamper alarm broadcast mode" min="0" max="1" value="0">
+ <Value type="list" genre="config" instance="1" index="26" label="Tamper alarm broadcast mode" min="0" max="1" value="0" size="1">
<Help>
The parameter determines whether the tamper alarm frame will or
will not be sent in broadcast mode. Alarm frames sent in broadcast
Oops, something went wrong.