Permalink
Browse files

Converted unsigned long long to uint64_t

Updated OZW configuration files
  • Loading branch information...
1 parent db1d6b9 commit c66a177604a37f6b0921aec5de814f11e129143d @gizmocuz gizmocuz committed Nov 12, 2016
Showing with 693 additions and 881 deletions.
  1. +3 −3 Config/BeNext/HeatingControl.xml
  2. +11 −11 Config/act/zdm230.xml
  3. +7 −7 Config/act/zdw103.xml
  4. +11 −11 Config/act/zdw232.xml
  5. +4 −4 Config/act/zrw103.xml
  6. +1 −1 Config/aeotec/dsc19103.xml
  7. +1 −1 Config/aeotec/zw062.xml
  8. +4 −4 Config/aeotec/zw089.xml
  9. +1 −1 Config/aeotec/zw090.xml
  10. +1 −1 Config/aeotec/zw095.xml
  11. +1 −1 Config/aeotec/zw098.xml
  12. +2 −2 Config/aeotec/zw112.xml
  13. +2 −2 Config/cooper/RF9505-T.xml
  14. +3 −3 Config/cooper/RF9540-N.xml
  15. +1 −1 Config/danfoss/rsroom.xml
  16. +1 −1 Config/everspring/an179.xml
  17. +1 −1 Config/everspring/an180.xml
  18. +1 −1 Config/everspring/an181.xml
  19. +6 −6 Config/evolve/ltm-5.xml
  20. +0 −174 Config/fibaro/fgr222.xml
  21. +1 −1 Config/fortrezz/mimolite.xml
  22. +1 −1 Config/horstmann/scsc17.xml
  23. +2 −2 Config/horstmann/sir321.xml
  24. +2 −2 Config/horstmann/srt323.xml
  25. +4 −3 Config/manufacturer_specific.xml
  26. +1 −1 Config/philio/pan03.xml
  27. +1 −1 Config/qubino/ZMNHADx.xml
  28. +1 −1 Config/qubino/ZMNHCDx.xml
  29. +2 −2 Config/remotec/zfm-80.xml
  30. +9 −9 Config/schlage/BE469NXCEN.xml
  31. +1 −1 Config/zwave.me/ZME_05431.xml
  32. +2 −2 Config/zwave.me/ZME_06436.xml
  33. +7 −6 hardware/Dummy.cpp
  34. +1 −1 hardware/EnOceanESP3.cpp
  35. +14 −13 hardware/MQTT.cpp
  36. +2 −2 hardware/MQTT.h
  37. +2 −4 hardware/MySensorsBase.cpp
  38. +7 −6 hardware/SBFSpot.cpp
  39. +1 −1 hardware/SBFSpot.h
  40. +13 −33 hardware/openzwave/DoxygenMain.h
  41. +1 −0 hardware/openzwave/Driver.h
  42. +6 −9 hardware/openzwave/Manager.h
  43. +8 −8 main/Camera.cpp
  44. +8 −8 main/Camera.h
  45. +70 −69 main/EventSystem.cpp
  46. +33 −33 main/EventSystem.h
  47. +1 −1 main/LuaHandler.cpp
  48. +6 −5 main/RFXNames.h
  49. +108 −108 main/SQLHelper.cpp
  50. +21 −21 main/SQLHelper.h
  51. +14 −13 main/Scheduler.cpp
  52. +2 −2 main/Scheduler.h
  53. +119 −121 main/WebServer.cpp
  54. +1 −1 main/mainstructs.h
  55. +90 −89 main/mainworker.cpp
  56. +8 −8 main/mainworker.h
  57. BIN msbuild/Debug/OpenZWaved.dll
  58. +24 −24 notifications/NotificationHelper.cpp
  59. +13 −13 notifications/NotificationHelper.h
  60. +3 −2 push/DataPush.cpp
  61. +1 −1 push/DataPush.h
  62. +3 −2 push/GooglePubSubPush.cpp
  63. +3 −2 push/HttpPush.cpp
  64. +1 −1 push/HttpPush.h
  65. +5 −4 push/Push.cpp
  66. +3 −3 push/Push.h
  67. +2 −2 tcpserver/TCPServer.cpp
  68. +3 −3 tcpserver/TCPServer.h
@@ -21,20 +21,20 @@
<Help>The value that the temperature setpoint must differ (compared to his previous send value) before an unsolicited temperature setpoint report is send to the associated node. Value in 0.1C .</Help>
</Value>
- <Value type="list" genre="config" instance="1" index="5" label="Unsolicited CRC" value="1">
+ <Value type="list" genre="config" instance="1" index="5" label="Unsolicited CRC" size="1" value="1">
<Help>TConfigure if the unsolicited reports are send with the CRC-16 encapsulation. Not that the receiving node should support this encapsulation to parse the Z-Wave frame!</Help>
<Item label="0x00 (disabled)" value="0"/>
<Item label="0x01 to 0xFF: enabled" value="1"/>
</Value>
- <Value type="list" genre="config" instance="1" index="6" label="Type of 'special' thermostat" value="0">
+ <Value type="list" genre="config" instance="1" index="6" label="Type of 'special' thermostat" size="1" value="0">
<Help>Type of 'special' thermostat: NOTE: when remeha Celcia 20 support is set then any other thermostat can not be set (!) NOTE2: when Remeha Celcia 20 gives 'Fout 203' send cfg value again</Help>
<Item label="0x00: No special" value="0"/>
<Item label="0x01: Remeha Celcia 20" value="1"/>
<Item label="0x02: Honeywell (rounded temperatures)" value="2"/>
</Value>
- <Value type="list" genre="config" instance="1" index="9" label="Enable/Disable thermostat schedule" value="0">
+ <Value type="list" genre="config" instance="1" index="9" label="Enable/Disable thermostat schedule" size="1" value="0">
<Help>Enable/Disable thermostat schedule inside the heatingcontroller.</Help>
<Item label="0x00: Disable thermostat schedule" value="0"/>
<Item label="0x01 - OFF: Enable thermostat schedule" value="1"/>
View
@@ -2,32 +2,32 @@
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<CommandClass id="112">
- <Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" value="1">
+ <Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" size="1" value="1">
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="2" genre="config" label="Suspend Group 4" value="0">
+ <Value type="list" index="2" genre="config" label="Suspend Group 4" size="1" value="0">
<Help>Disable transmitting commands to Z-Wave devices that are in Group 4 without disassociating those devices from the group.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="3" genre="config" label="Night Light" value="0">
+ <Value type="list" index="3" genre="config" label="Night Light" size="1" value="0">
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="4" genre="config" label="Invert Switch" value="0">
+ <Value type="list" index="4" genre="config" label="Invert Switch" size="1" value="0">
<Help>Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" value="1">
+ <Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" size="1" value="1">
<Help>This dimmer will start dimming from its current level.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="6" genre="config" label="Don't Send Level After Dim" value="1">
+ <Value type="list" index="6" genre="config" label="Don't Send Level After Dim" size="1" value="1">
<Help>When you press and hold the bottom of the ZDM230 switch once, the Z-Wave devices that are associated into Group 1 are sent the Dim command. If this parameter is set to &quot;Yes&quot; the devices in Group 1 will not go to the same level as the ZDM230.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
@@ -50,22 +50,22 @@
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
</Value>
- <Value type="list" index="13" genre="config" label="Disable Group 4 During Dim">
+ <Value type="list" index="13" genre="config" label="Disable Group 4 During Dim" size="1">
<Help>Units in Group 4 only track when the dimmer is being turned ON and OFF and not while dimming.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" value="0">
+ <Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" size="1" value="0">
<Help>The ZDM230 can operate shade control devices via its group 2.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" value="0">
+ <Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" size="1" value="0">
<Help>The ZDM230 can operate shade control devices via its group 3.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
+ <Value type="list" index="19" genre="config" label="LED Transmission Indication" size="1" value="2">
<Help>The ZDM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
<Item label="None" value="0" />
<Item label="While Transmitting" value="1" />
@@ -74,7 +74,7 @@
<Value type="byte" index="20" genre="config" label="Poll Group 2 Interval" units="minutes" min="1" max="255" value="2">
<Help>Poll Group 2 Interval</Help>
</Value>
- <Value type="list" index="22" genre="config" label="Enable Group 2 Polling">
+ <Value type="list" index="22" genre="config" label="Enable Group 2 Polling" size="1">
<Help>Poll Group 2</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
View
@@ -2,22 +2,22 @@
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<CommandClass id="112">
- <Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" value="1">
+ <Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" size="1" value="1">
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="3" genre="config" label="Night Light" value="0">
+ <Value type="list" index="3" genre="config" label="Night Light" size="1" value="0">
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="4" genre="config" label="Invert Switch" value="0">
+ <Value type="list" index="4" genre="config" label="Invert Switch" size="1" value="0">
<Help>Change the top of the switch to OFF and the bottom of the switch to ON.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" value="1">
+ <Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" size="1" value="1">
<Help>This dimmer will start dimming from its current level.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
@@ -40,17 +40,17 @@
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
</Value>
- <Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" value="0">
+ <Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" size="1" value="0">
<Help>The ZDW103 can operate shade control devices via its group 2.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" value="0">
+ <Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" size="1" value="0">
<Help>The ZDW103 can operate shade control devices via its group 3.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
+ <Value type="list" index="19" genre="config" label="LED Transmission Indication" size="1" value="2">
<Help>The ZDW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
<Item label="None" value="0" />
<Item label="While Transmitting" value="1" />
View
@@ -2,7 +2,7 @@
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<CommandClass id="112">
- <Value type="list" index="1" genre="config" label="Set Ignore Start Level Bit When Transmitting Dim Commands" value="1">
+ <Value type="list" index="1" genre="config" label="Set Ignore Start Level Bit When Transmitting Dim Commands" size="1" value="1">
<Help>
The ZDW232 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded
in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a
@@ -13,7 +13,7 @@ level.
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="2" genre="config" label="Suspend Group 4" value="0">
+ <Value type="list" index="2" genre="config" label="Suspend Group 4" size="1" value="0">
<Help>You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without "un-associating"
those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW232 from transmitting to devices
that are "associated" into Group 4.
@@ -22,17 +22,17 @@ and not when dimming.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="3" genre="config" label="Night Light" value="0">
+ <Value type="list" index="3" genre="config" label="Night Light" size="1" value="0">
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="4" genre="config" label="Invert Switch" value="0">
+ <Value type="list" index="4" genre="config" label="Invert Switch" size="1" value="0">
<Help>To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="5" genre="config" label="Ignore Start Level When Receiving Dim Commands" value="1">
+ <Value type="list" index="5" genre="config" label="Ignore Start Level When Receiving Dim Commands" size="1" value="1">
<Help>The ZDW232 can be set to ignore the start level that is part of the dim command, regardless of whether the command
is telling the dimmer to ignore the start level or not ignore the start level embedded in the command (see Parameter
1). Setting parameter 5 to a value of 1 (factory default) will cause the ZDW232 to ignore the start level and to dim
@@ -41,7 +41,7 @@ the command.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="6" genre="config" label="Don't Send Level Command After Transmitting Dim Commands" value="1">
+ <Value type="list" index="6" genre="config" label="Don't Send Level Command After Transmitting Dim Commands" size="1" value="1">
<Help>When you press and hold the bottom of the ZDW232 switch once, the Z-Wave devices that areassociated into Group
1 are sent the Dim command. If parameter 6 is set to 0, after you release the switch, the ZDW232 will command
devices in that group to go to the same level of the ZDW232. If parameter 6 is set to a value of 1 (factory default)
@@ -67,24 +67,24 @@ the devices in Group 1 will not go to the same level of the ZDW232.</Help>
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
</Value>
- <Value type="list" index="13" genre="config" label="Disable Group 4 During Dim">
+ <Value type="list" index="13" genre="config" label="Disable Group 4 During Dim" size="1">
<Help>After the ZDW232 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to the
ZDW232's new level. To prevent the ZDW232 from commanding the Z-Wave devices in Group 4 during this particular
occurrence, set Parameter 13 to the value of 1.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" value="0">
+ <Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" size="1" value="0">
<Help>The ZDW232 can operate shade control devices via its group 2 if this configuration parameter is set to 1.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" value="0">
+ <Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" size="1" value="0">
<Help>The ZDW232 can operate shade control devices via its group 3 if this configuration parameter is set to 1.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
+ <Value type="list" index="19" genre="config" label="LED Transmission Indication" size="1" value="2">
<Help>The ZDW232 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
<Item label="None" value="0" />
<Item label="While Transmitting" value="1" />
@@ -93,7 +93,7 @@ occurrence, set Parameter 13 to the value of 1.</Help>
<Value type="byte" index="20" genre="config" label="Poll Group 2 Interval" units="minutes" min="1" max="255" value="2">
<Help>Poll Group 2 Interval</Help>
</Value>
- <Value type="list" index="22" genre="config" label="Enable Group 2 Polling">
+ <Value type="list" index="22" genre="config" label="Enable Group 2 Polling" size="1">
<Help>Poll Group 2</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
@@ -2,22 +2,22 @@
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration Parameters -->
<CommandClass id="112">
- <Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" value="1">
+ <Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" size="1" value="1">
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="3" genre="config" label="Night Light" value="0">
+ <Value type="list" index="3" genre="config" label="Night Light" size="1" value="0">
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="4" genre="config" label="Invert Switch" value="0">
+ <Value type="list" index="4" genre="config" label="Invert Switch" size="1" value="0">
<Help>Change the top of the switch to OFF and the bottom of the switch to ON.</Help>
<Item label="No" value="0" />
<Item label="Yes" value="1" />
</Value>
- <Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
+ <Value type="list" index="19" genre="config" label="LED Transmission Indication" size="1" value="2">
<Help>The ZRW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
<Item label="None" value="0" />
<Item label="While Transmitting" value="1" />
@@ -150,7 +150,7 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584517
<Item label="Unidentified Mode" value="255" />
</Value>
<!-- This is only present in Firmware 1.20
- <Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" value="0">
+ <Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" size="1" value="0">
<Help>Lock/ unlock all configuration parameters</Help>
<Item label="Unlock" value="0"/>
<Item label="Lock" value="1"/>
@@ -145,7 +145,7 @@ https://aeotec.freshdesk.com/helpdesk/attachments/6009584687
<Item label="Start the pairing of Sensor" value="1431655681"/>
<Item label="Pairing is successful" value="511"/>
</Value>
- <Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" value="0">
+ <Value type="list" genre="config" index="252" label="Lock/Unlock Configuration" min="0" max="1" size="1" value="0">
<Help>Lock/ unlock all configuration parameters</Help>
<Item label="Unlock" value="0"/>
<Item label="Lock" value="1"/>
Oops, something went wrong.