Repository navigation
DDF for MoesGo/Tuya Smart Dimmer Module (_TZE200_e3oitdyu) - #5869
Conversation
|
This is concerning the 2-gang Moes dimmer _TZE200_e3oitdyu. Thanks for the great work integrating this in DeConz. I have a problem however when I integrate these dimmers into groups: I cannot turn on/off or dim the entire group, and I cannot recall scenes for the group. The groups and scene work fine for the Moes 3-gang smart switch, however. |
|
It's a tuya device. |
|
However, with the Moes 3-gang switch: _TZ3000_pfc7i3kt groups and scenes work fine, and it's also a Tuya device with multiple subdevices. Is there something that can be learned from the way it's been integrated? |
I m not sure ton understand, you mean about the group support ? Just look wich one cluster the device use for on/off for exemple. |
The PR depends on #5868
For Tuya devices it adds the
devices/tuya/tuya_swversion.jswhich should be used to correctly parse theattr/swversionitem.The Tuya firmware version is stored in ZCL Basic cluster Application Version 8-bit attribute as packed major.minor.patch version. For example: 0x41 results in
0b 01 00 0001 = 1.0.1.The device provides two REST-API lights with on/off and dimming, unfortunately no button events.