xiaomi/xiaomi_wsdcgq11lm_temp_hum_press_sensor.json
was introduced, a workaround for #1748 was removed.This PR brings the workaround to the DDF. I have simply added the
parse
section fromgeneric/items/state_temperature_item.json
and modified it with anif
.I did test that this works but I have no experience with DDF so I am quite sure that there is an improved way to do it.