This mainly affects ConBee III but could also affect ConBee II when the setup is downgraded from ConBee III.

Force old school Zigbee join/re-join without APS level per device link keys for now via Node Descriptor server mask. Since the random generated per device link keys aren't stored or backuped anywhere, this caused problems for rejoining devices of some brands and perhaps battery drain. For proper support of per device APS link keys we need further code to store them in database and forward to firmware.

See code comment. This mainly affects ConBee III but could also affect ConBee II when setup is downgraded from ConBee III.
@manup manup added the Fix label Dec 27, 2023
@manup manup added this to the v2.25.1 milestone Dec 27, 2023
@manup manup merged commit 5fc6751 into dresden-elektronik:master Dec 27, 2023
@manup manup deleted the classic_join branch December 27, 2023 20:50
manup added a commit that referenced this pull request Jan 20, 2024
See code comment. This mainly affects ConBee III but could also affect ConBee II when setup is downgraded from ConBee III.
@xxLeoxx93
Copy link

I'm facing the high battary drain using Conbee 3 (and downgrade to 2) in combination with Homeassistant/ZHA. Is this now fixed wit hthe latest firmware?