Force classic join/re-join for devices #7497
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This mainly affects ConBee III but could also affect ConBee II when the setup is downgraded from ConBee III.
Force old school Zigbee join/re-join without APS level per device link keys for now via Node Descriptor server mask. Since the random generated per device link keys aren't stored or backuped anywhere, this caused problems for rejoining devices of some brands and perhaps battery drain. For proper support of per device APS link keys we need further code to store them in database and forward to firmware.