Skip to content

Conversation

@mattreim
Copy link
Contributor

Aqara Single Switch Module T1 (With Neutral):

Aqara Single Switch Module T1

@mattreim mattreim changed the title Fix temperature reporting for Aqara Single Switch Module T1 (With Neutral) Fix temperature reporting for Aqara Single Switch Module T1 (With Neutral) SSM-U01 Mar 21, 2024
@manup manup added the Fix label Mar 28, 2024
@manup manup added this to the v2.27.0-beta milestone Mar 28, 2024
@manup manup merged commit 3a4a0c8 into dresden-elektronik:master Mar 28, 2024
@SwoopX
Copy link
Collaborator

SwoopX commented Mar 28, 2024

Hi,

I'm afraid this one should have never made it into the DDF, this one slipped me. We currently do not have any resource item for device temperatures and using a config/ item for a state value is not the intended way. Of course, locally, you're absolutely free to do as you please, one of the DDF benefits I might add.

@manup In my view, we should revert this PR.

@mattreim
Copy link
Contributor Author

In this case it was already there and I just repaired it.

@mattreim
Copy link
Contributor Author

mattreim commented Mar 30, 2024

device_temperature

Do you now want to remove all device temperatures?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

Projects

None yet

Development

Successfully merging this pull request may close these issues.

3 participants