Skip to content

Hue MotionAware - #8343

Merged
manup merged 3 commits into
dresden-elektronik:masterfrom
ebaauw:motionaware
Oct 20, 2025
Merged

manup merged 3 commits into
dresden-elektronik:masterfrom
ebaauw:motionaware

Conversation

@ebaauw

@ebaauw ebaauw commented Oct 7, 2025 •

Copy link
Copy Markdown
Collaborator

I would open an issue, but they only support bug reports or device requests. I suppose this is a feature request, but you could also see it as enhancement for Hue devices that support MotionAware.

This PR updates general.xml, adding support for Hue MotionAware to the deCONZ GUI. With these updates, you can manually setup a Hue MotionAware group and start or stop the reporting of raw data to the deCONZ gateway. I don't yet know how to interpret the raw data, but I figured monitoring it in the GUI is a good first step.

Hue devices that support Hue MotionAware carry the Hue MotionAware (0xFC04) server cluster. As far as I can tell, this cluster supports:

  • One attribute, Capabilities, listing the device capabilities, presumably: sensor, collector, and sync, as reported by the Hue API v2;
  • Three incoming commands: Configure, Start and Stop; and
  • One outgoing command, Report, for reporting the raw data. It would appear the logic to convert the raw data to motion events runs on the Hue Bridge Pro.

A MotionAware group consists of three or four devices. One is the proxy, the others are members. It is identified by an ID. The Hue Bridge Pro reconfigures the group, incrementing the ID each time the motion area is activated.
When active, all devices in the group continuously send MAC level broadcasts, using the ZLL Commissioning cluster with the raw radio signal strength data. This data is collected by the proxy who continuously sends Report to the coordinator (note that the Hue Bridge Pro is a proper coordinator, with NWK address 0x0000).

Configure, Start, and Stop are sent to the proxy and to each member; only the proxy sends Report. The raw data for groups of three devices consists of 6 bytes (presumably 3 devices, each reporting signal strength to 2 neighbours); for four devices, it consists of 12 bytes (presumably 4 devices reporting 3 neighbours each).

The proxy is configured with all roles and member nr 0; the members only acts as sensor and use subsequent member nrs. The first unknown parameter always seems to be 0x0190; the second unknown parameter is 0, 133, 266 for groups of three and 0, 100, 200, 300 for groups of four.

Screenshot 2025-10-07 at 16 49 16 Screenshot 2025-10-07 at 16 50 02

Add Hue-specific MotionAware cluster 0xFC04
@ebaauw ebaauw added Device Improvement Additional tag to attach to a existing issue. Enhancement labels Oct 7, 2025
@manup manup added this to the v2.32.0-beta milestone Oct 7, 2025
@manup
manup merged commit 0643eb6 into dresden-elektronik:master Oct 20, 2025
@ebaauw
ebaauw deleted the motionaware branch October 23, 2025 20:38
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

Device Improvement Additional tag to attach to a existing issue. Enhancement

Projects

None yet

Development

Successfully merging this pull request may close these issues.