New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[3.0] Input focus feedback lost after reloading webview #15318

Open
magne4000 opened this Issue Oct 22, 2018 · 1 comment

Comments

3 participants
@magne4000
Copy link

magne4000 commented Oct 22, 2018

  • Output of node_modules/.bin/electron --version: v3.0.5
  • Operating System (Platform and Version): MacOS 10.14
  • Output of node_modules/.bin/electron --version on last known working Electron version (if applicable): v2.x

Expected Behavior
After reloading webview, focusing an input should be visible

Actual behavior
Before reloading webview:

  • clicking inside/outside the input show/hide the outline around the input
    After reloading webview:
  • clicking inside the input doesn't the outline anymore
  • If I focus another Application, and get back to Electron, it is not broke anymore

To Reproduce

$ git clone https://github.com/magne4000/electron-quick-start.git -b bug/reload-focus-feedback
$ npm install
$ npm start || electron .

Screenshots

outline is visible

image

outline is not visible

image

@magne4000 magne4000 added the 3-0-x label Oct 22, 2018

@sofianguy sofianguy added this to Needs Review in 3.0.x Oct 22, 2018

@javan

This comment has been minimized.

Copy link
Contributor

javan commented Oct 23, 2018

Pretty sure this is the same issue as #14474 (#14474 (comment) works around it, for me).

catouse added a commit to easysoft/xuanxuan that referenced this issue Jan 2, 2019

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment