1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
; change filament without AMS g-code
{if toolchange_count > 1}
M204 S9000 ; set starting acceleration
G17 ; set CNC workspace plane
G2 Z{max_layer_z + 0.4} I0.86 J0.86 P1 F10000 ; spiral lift
G1 Z{max_layer_z + 3.0} F1200 ; vertical lift
; move to poop chute
G1 X70 F21000
G1 Y245
G1 Y265 F3000
M400
; turn off fans P1 and P2
M106 P1 S0
M106 P2 S0
; wipe?
G1 X90 F3000
G1 Y255 F4000
G1 X100 F5000
G1 X120 F15000
; move to position to prep for cutting filament
G1 X20 Y50 F21000
G1 Y-3
; always use highest temperature to flush
M400
M109 S[nozzle_temperature_range_high]
; cut filament
G1 X5 F300
G1 X20 F12000
; move to poop chute
G1 X70 F12000
G1 Y245
G1 Y265 F3000
; push a little filament out and then retract out
G1 E10 F200
G1 E-10 F200
G1 E-20 F500
; pause for user to load and press resume
M400 U1
; don't know when next_extruder is >=255, so this may always activate?
{if next_extruder < 255}
M400
G92 E0
{if flush_length_1 > 1}
; FLUSH_START
{if flush_length_1 > 23.7}
G1 E23.7 F{old_filament_e_feedrate} ; do not need pulsatile flushing for start part
G1 E{(flush_length_1 - 23.7) * 0.02} F50
G1 E{(flush_length_1 - 23.7) * 0.23} F{old_filament_e_feedrate}
G1 E{(flush_length_1 - 23.7) * 0.02} F50
G1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}
G1 E{(flush_length_1 - 23.7) * 0.02} F50
G1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}
G1 E{(flush_length_1 - 23.7) * 0.02} F50
G1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}
{else}
G1 E{flush_length_1} F{old_filament_e_feedrate}
{endif}
; FLUSH_END
G1 E-[old_retract_length_toolchange] F1800
G1 E[old_retract_length_toolchange] F300
{endif}
{if flush_length_2 > 1}
; FLUSH_START
G1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_2 * 0.02} F50
G1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_2 * 0.02} F50
G1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_2 * 0.02} F50
G1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_2 * 0.02} F50
G1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_2 * 0.02} F50
; FLUSH_END
G1 E-[new_retract_length_toolchange] F1800
G1 E[new_retract_length_toolchange] F300
{endif}
{if flush_length_3 > 1}
; FLUSH_START
G1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_3 * 0.02} F50
G1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_3 * 0.02} F50
G1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_3 * 0.02} F50
G1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_3 * 0.02} F50
G1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_3 * 0.02} F50
; FLUSH_END
G1 E-[new_retract_length_toolchange] F1800
G1 E[new_retract_length_toolchange] F300
{endif}
{if flush_length_4 > 1}
; FLUSH_START
G1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_4 * 0.02} F50
G1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_4 * 0.02} F50
G1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_4 * 0.02} F50
G1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_4 * 0.02} F50
G1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}
G1 E{flush_length_4 * 0.02} F50
; FLUSH_END
{endif}
; FLUSH_START
M400
M109 S[new_filament_temp]
G1 E2 F{new_filament_e_feedrate} ;Compensate for filament spillage during waiting temperature
; FLUSH_END
M400
G92 E0
G1 E-[new_retract_length_toolchange] F1800
M106 P1 S255
M400
G1 X80 F15000
G1 X60 F15000
G1 X80 F15000
G1 X60 F15000; shake to put down garbage
G1 X70 F5000
G1 X90 F3000
G1 Y255 F4000
G1 X100 F5000
G1 Y265 F5000
G1 X70 F10000
G1 X100 F5000
G1 X70 F10000
G1 X100 F5000
G1 X165 F15000; wipe and shake
G1 Y256 ; move Y to aside, prevent collision
M400
G1 Z[z_after_toolchange] F3000
{if layer_z <= (initial_layer_print_height + 0.001)}
M204 S[initial_layer_acceleration]
{else}
M204 S[default_acceleration]
{endif}
{else}
G1 X[x_after_toolchange] Y[y_after_toolchange] Z[z_after_toolchange] F12000
{endif}
{endif}
; as there is no AMS, these next three lines only serve to hide T[next_extruder]
; if this was not included, the T[next_extruder] command is input after this
; code and will cause the system to hang as the toolchange command searches
; for the AMS
M620 S[next_extruder]A
T[next_extruder]
M621 S[next_extruder]A