network: schema: http host: evcc.local port: 7070 interval: 10s # control cycle interval # log settings log: info levels: site: debug lp-1: debug lp-2: debug cache: error db: error # meter definitions # for documentation see https://docs.evcc.io/docs/devices/meters meters: - name: mt175 type: template template: tasmota usage: grid host: 192.168.178.31 # IP-Adresse oder Hostname user: admin password: xxx # charger definitions # for documentation see https://docs.evcc.io/docs/devices/chargers chargers: - name: steckdose type: template template: tasmota host: 192.168.178.19 # IP-Adresse oder Hostname user: # Standard-User ist admin (Optional) password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional) channel: 1 # Nummer des Schaltkanals (1-8), bei Geräten mit mehr als einem Schalter standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional) # vehicle definitions # for documentation see https://docs.evcc.io/docs/devices/vehicles vehicles: - name: tesla_model_3 type: template template: tesla title: Tesla Model 3 accessToken: xxx refreshToken: xxx vin: # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind (Optional) capacity: 77 # Akkukapazität in kWh (Optional) targetSoc: 95 minCurrent: 2 maxCurrent: 6 # site describes the EVU connection, PV and home battery site: title: Home # display name for UI meters: grid: mt175 residualPower: 0 # egt den Soll-Arbeitspunkt der Überschussregelung am Netzübergang (Gridmeter) fest. Der Standardwert ist 0 W. Negative Werte verschieben den Sollwert in Richtung Netzeinspeisung, positive Werte in Richtung Netzbezug. Letztendlich wird mit diesem Wert der durch die Steuerung einzustellende "Ruhezustand" des Regelkreises eingestellt. prioritySoc: 0 # give home battery priority up to this soc (empty to disable) bufferSoc: 0 # continue charging on battery above soc (0 to disable) bufferStartSoc: 0 # start charging on battery above soc (0 to disable) maxGridSupplyWhileBatteryCharging: 0 # ignore battery charging if AC consumption is above this value smartCostLimit: 0 # set cost limit for automatic charging in PV mode # loadpoint describes the charger, charge meter and connected vehicle loadpoints: - title: Garage # display name for UI charger: steckdose # charger mode: pv # set default charge mode vehicle: tesla_model_3 resetOnDisconnect: true # set defaults when vehicle disconnects phases: 1 # electrical connection (normal charger: default 3 for 3 phase, 1p3p charger: 0 for "auto" or 1/3 for fixed phases) minCurrent: 2 # minimum charge current (default 6A) maxCurrent: 6 # maximum charge current (default 16A) # remaining settings are experts-only and best left at default values priority: 0 soc: poll: mode: charging interval: 60m estimate: true # set false to disable interpolating between api updates (not recommended) enable: # pv mode enable behavior delay: 1m # threshold must be exceeded for this long threshold: 0 # grid power threshold (in Watts, negative=export). If zero, export must exceed minimum charge power to enable disable: # pv mode disable behavior delay: 3m # threshold must be exceeded for this long threshold: 0 # maximum import power (W) guardDuration: 5m # switch charger contactor not more often than this (default 5m) # push messages messaging: events: start: # charge start event title: Charge started msg: Started charging in "${mode}" mode stop: # charge stop event title: Charge finished msg: Finished charging ${chargedEnergy:%.1fk}kWh in ${chargeDuration}. connect: # vehicle connect event title: Car connected msg: "Car connected at ${pvPower:%.1fk}kW PV" disconnect: # vehicle connected event title: Car disconnected msg: Car disconnected after ${connectedDuration} soc: # vehicle soc update event title: Soc updated msg: Battery charged to ${vehicleSoc:%.0f}% guest: # vehicle could not be identified title: Unknown vehicle msg: Unknown vehicle, guest connected?